Numerical Investigation of Temperature Distribution in a Water Cooling Tank under Natural Convection

被引:1
|
作者
Kusuma, Mukhsinun Hadi [1 ]
Sundari, Titik [2 ]
Antariksawan, Anhar Riza [1 ]
Ismarwanti, Sri [3 ]
Juarsa, Mulya [1 ]
Putra, Nandy [4 ]
Widodo, Surip [1 ]
Ardiyati, Tanti [5 ]
Subekti, Muhammad [1 ]
Artiani, Pungki Ayu [2 ]
机构
[1] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Nucl Reactor Technol & Safety, Tangerang Selatan 15314, Indonesia
[2] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Radioact Waste Technol, Tangerang Selatan 15314, Indonesia
[3] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Nucl Fuel Technol, Tangerang Selatan 15314, Indonesia
[4] Univ Indonesia, Dept OfMech Engn, Heat Transfer Lab, Kampus UI, Depok 16424, Indonesia
[5] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Nucl Facil Engn, Tangerang Selatan 15314, Indonesia
来源
10TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2018): SMART CITY: ADVANCES IN THERMOFLUID TECHNOLOGY IN TROPICAL URBAN DEVELOPMENT | 2019年 / 2062卷
关键词
HEAT REMOVAL SYSTEM; PERFORMANCE; REACTOR; POOL;
D O I
10.1063/1.5086557
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
In a typical small modular reactor, an emergency cooling tank acts as additional safety feature that is intended to cope with an emergency situation. Water inside the cooling tank absorbs residual heat from the reactor core when an accident occurs through a system designed for that purpose. In the emergency cooling tank, a heat exchanger is used to transfer the heat from the core to the water coolant under natural convection. For studying this emergency cooling system, an experimental facility was designed, namely FASSIP-02. The objective of this study was to investigate the temperature distribution inside the water cooling tank under natural convection. The numerical code Fluent 6.3 and RELAP5 were used to investigate the heat transfer phenomena from the heat exchanger to the water cooling tank. The water cooling tank, which was one of the important components in simulating the emergency cooling tank, was made from carbon steel with length of 3100 nun, width of 1100 mm, and height of 2750 mm. The water with initial temperature of 300 K was tilled into the cooling tank as high as 2000 nun A U-shaped heat exchanger that was made from copper tube with inner diameter of 25.4 mm, outside diameter of 27.4 mm, length of 4200 nun, and thickness of 1 mill was inunersed in the cooling tank. The hot water with various temperatures of 343, 353, and 363 K was assumed to flow inside the heat exchanger, while the velocities of the hot water were varied from 0.05, 0.5, to I m/s. The simulation results obtained show that an increasing of temperature and velocity of the hot water inside the U-shaped heat exchanger resulted in increasing of heat transferred to the water and water temperature in the cooling tank. The natural single-phase convection affected the heat transfer.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Thermo-hydraulic characteristics of thermal interface induced by natural convection in water tank with internal heat source
    Han, Fei
    Feng, Debin
    Xin, Pengfei
    Wang, Wen
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 211
  • [32] Numerical simulation of water spray for pre-cooling of inlet air in natural draft dry cooling towers
    Alkhedhair, Abdullah
    Gurgenci, Hal
    Jahn, Ingo
    Guan, Zhiqiang
    He, Suoying
    APPLIED THERMAL ENGINEERING, 2013, 61 (02) : 416 - 424
  • [33] Effect mechanism of exit-water temperature distribution characteristics on the anti-freezing of natural draft dry cooling tower
    Li Wendong
    Wang Huitao
    Wang Jian
    Duan Chongpeng
    Zhao Yuanbin
    APPLIED THERMAL ENGINEERING, 2019, 161
  • [34] Experimental and numerical investigation of natural convection heat transfer of W-type fin arrays
    Zhang, Kai
    Li, Ming-Jia
    Wang, Fei-Long
    He, Ya-Ling
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 152
  • [35] Numerical investigation on using inclined partitions to reduce natural convection inside the cavities of hollow bricks
    Alhazmy, Majed M.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (11) : 2201 - 2210
  • [36] The Estimation of Temperature Distribution in Cylindrical Battery Cells Under Unknown Cooling Conditions
    Kim, Youngki
    Mohan, Shankar
    Siegel, Jason B.
    Stefanopoulou, Anna G.
    Ding, Yi
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2014, 22 (06) : 2277 - 2286
  • [37] Numerical study on the dynamic response of a massive liquefied natural gas outer tank under impact loading
    Yan, Chen
    Zhai, Xi-mei
    Wang, Yong-hui
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2019, 20 (11): : 823 - 837
  • [38] Numerical Analysis of Natural Convection in an Annular Cavity Filled with Hybrid Nanofluids under Magnetic Field
    Benkherbache, Souad
    Amroune, Salah
    Belaadi, Ahmed
    Zergane, Said
    Farsi, Chouki
    ENERGIES, 2024, 17 (18)
  • [39] Numerical Investigation of Liquid Water Cooling for a Proton Exchange Membrane Fuel Cell Stack
    Sasmito, Agus P.
    Birgersson, Erik
    Mujumdar, Arun S.
    HEAT TRANSFER ENGINEERING, 2011, 32 (02) : 151 - 167
  • [40] Numerical investigation of high temperature metal hydride water pumping system
    Askri, Faouzi
    Miled, Amel
    Mellouli, Sofiene
    Ben Maad, Hatem
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (31) : 16777 - 16792