Numerical Investigation of Temperature Distribution in a Water Cooling Tank under Natural Convection

被引:1
|
作者
Kusuma, Mukhsinun Hadi [1 ]
Sundari, Titik [2 ]
Antariksawan, Anhar Riza [1 ]
Ismarwanti, Sri [3 ]
Juarsa, Mulya [1 ]
Putra, Nandy [4 ]
Widodo, Surip [1 ]
Ardiyati, Tanti [5 ]
Subekti, Muhammad [1 ]
Artiani, Pungki Ayu [2 ]
机构
[1] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Nucl Reactor Technol & Safety, Tangerang Selatan 15314, Indonesia
[2] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Radioact Waste Technol, Tangerang Selatan 15314, Indonesia
[3] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Nucl Fuel Technol, Tangerang Selatan 15314, Indonesia
[4] Univ Indonesia, Dept OfMech Engn, Heat Transfer Lab, Kampus UI, Depok 16424, Indonesia
[5] Natl Nucl Energy Agcy Indonesia BATAN, Ctr Nucl Facil Engn, Tangerang Selatan 15314, Indonesia
来源
10TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2018): SMART CITY: ADVANCES IN THERMOFLUID TECHNOLOGY IN TROPICAL URBAN DEVELOPMENT | 2019年 / 2062卷
关键词
HEAT REMOVAL SYSTEM; PERFORMANCE; REACTOR; POOL;
D O I
10.1063/1.5086557
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
In a typical small modular reactor, an emergency cooling tank acts as additional safety feature that is intended to cope with an emergency situation. Water inside the cooling tank absorbs residual heat from the reactor core when an accident occurs through a system designed for that purpose. In the emergency cooling tank, a heat exchanger is used to transfer the heat from the core to the water coolant under natural convection. For studying this emergency cooling system, an experimental facility was designed, namely FASSIP-02. The objective of this study was to investigate the temperature distribution inside the water cooling tank under natural convection. The numerical code Fluent 6.3 and RELAP5 were used to investigate the heat transfer phenomena from the heat exchanger to the water cooling tank. The water cooling tank, which was one of the important components in simulating the emergency cooling tank, was made from carbon steel with length of 3100 nun, width of 1100 mm, and height of 2750 mm. The water with initial temperature of 300 K was tilled into the cooling tank as high as 2000 nun A U-shaped heat exchanger that was made from copper tube with inner diameter of 25.4 mm, outside diameter of 27.4 mm, length of 4200 nun, and thickness of 1 mill was inunersed in the cooling tank. The hot water with various temperatures of 343, 353, and 363 K was assumed to flow inside the heat exchanger, while the velocities of the hot water were varied from 0.05, 0.5, to I m/s. The simulation results obtained show that an increasing of temperature and velocity of the hot water inside the U-shaped heat exchanger resulted in increasing of heat transferred to the water and water temperature in the cooling tank. The natural single-phase convection affected the heat transfer.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] The experimental/numerical investigation of variations in strip speed, water shower pattern and water temperature on high-temperature strip cooling rate in hot strip mill
    Kerdabadi, Javad Karimi
    Haghanimanesh, Maedeh
    Karimipour, Arash
    Toghraie, Davood
    Tlili, Iskander
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 143 (01) : 293 - 308
  • [22] Numerical investigation of the operating process of the liquid hydrogen tank under gaseous hydrogen pressurization
    Li, Jiachao
    Liang, Guozhu
    Zhu, Pingping
    Wang, Xi
    AEROSPACE SCIENCE AND TECHNOLOGY, 2019, 93
  • [23] Numerical investigation of natural convection from a horizontal heat sink with an array of rectangular fins
    Sultan, Hussein S.
    Saleem, Khalid B.
    Alshammari, Badr M.
    Turki, Mohamed
    Aydi, Abdelkarim
    Kolsi, Lioua
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [24] Numerical investigation on natural convection heat transfer of the annular structure in heat exchangers and solenoids
    Tan, Sheng-Yu
    Liu, Jie
    Lu, Wen-Qiang
    APPLIED THERMAL ENGINEERING, 2019, 150 : 674 - 685
  • [25] A Numerical and Experimental Study of a Novel Heat Sink Design for Natural Convection Cooling of LED Grow Lights
    Adhikari, Ram
    Beyragh, Dawood
    Pahlevani, Majid
    Wood, David
    ENERGIES, 2020, 13 (16)
  • [26] A comparison of temperature distribution in PEMFC with single-phase water cooling and two-phase HFE-7100 cooling methods by numerical study
    Choi, Eun Jung
    Park, Jin Young
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (29) : 13406 - 13419
  • [27] NUMERICAL SIMULATIONS FOR SUPER LARGE-SCALE NATURAL DRAFT COOLING TOWER WITH AN OPTIMIZED NON-UNIFORM WATER DISTRIBUTION
    Li, J. Y.
    Wang, H.
    Sheng, W.
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 8, 2017,
  • [28] Investigation of water phase change rotating cooling for high temperature turbine
    Sun, Hongchuang
    Gao, Peng
    Li, Haokai
    Hou, Feng
    Yuan, Pei
    RESULTS IN ENGINEERING, 2024, 21
  • [29] Numerical investigation of liquid nitrogen spray cooling under low ambient pressure
    Liu, Xianlong
    Du, Chenhui
    Zhu, Jiawei
    Kang, Huifang
    Ding, Chen
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 233
  • [30] Heat Transfer Analysis of Passive Residual Heat Removal Heat Exchanger under Natural Convection Condition in Tank
    Men, Qiming
    Wang, Xuesheng
    Zhou, Xiang
    Meng, Xiangyu
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2014, 2014