Background: Although aortic valve replacement (AVR) is the only effective treatment for patients with aortic stenosis (AS), it is recognized that the use of small prosthetic valves due to a small aortic root often affects postoperative course after AVR. The aim of this study was to determine whether the use of small prosthetic valves was a risk factor of AVR for AS. Methods: We compared various perioperative factors and operative outcomes between patients with a small mechanical prosthetic valve (small group) and patients with a large mechanical prosthetic valve (large group). Results: Early mortality was 0% in each group and the 5-year mortality was 25% in the small group and 10% in the large group. There were no significant differences in perioperative factors between the two groups. The small group patients were significantly older and smaller compared to the large group patients. The valve size was significantly correlated with age and BSA. Conclusions: The use of small mechanical prostheses was not a risk factor of AVR for AS when it was proportionate to the BSA even for elderly patients. AVR using a small mechanical prosthetic valve may be performed with good results in the short- and long-term.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 15 条
[1]  
BLANK RH, 1976, ANN THORAC SURG, V22, P356, DOI 10.1016/S0003-4975(10)64967-3
[2]  
BORTOLOTTI U, 1987, J THORAC CARDIOV SUR, V94, P200
[3]  
CHAUX A, 1981, J THORAC CARDIOV SUR, V81, P202
[4]  
DAVIS EA, 1994, CIRCULATION S2, V94, P121
[5]   INTRINSIC FAILURE OF HANCOCK MITRAL BIOPROSTHESES - 10-YEAR TO 15-YEAR EXPERIENCE [J].
FOSTER, AH ;
GREENBERG, GJ ;
UNDERHILL, DJ ;
MCINTOSH, CL ;
CLARK, RE .
ANNALS OF THORACIC SURGERY, 1987, 44 (06) :568-577
[6]   Influence of the size of aortic valve prostheses on hemodynamics and change in left ventricular mass: Implications for the surgical management of aortic stenosis [J].
GonzalezJuanatey, JR ;
GarciaAcuna, JM ;
Fernandez, MV ;
Cendon, AA ;
Fuentes, VC ;
GarciaBengoechea, JB ;
delaPena, MG .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (02) :273-280
[7]   PREDICTION OF POSTOPERATIVE EXERCISE TOLERANCE AFTER AORTIC-VALVE REPLACEMENT [J].
HIROOKA, K ;
KAWAZOE, K ;
KOSAKAI, Y ;
SASAKO, Y ;
EISHI, K ;
KITO, Y ;
NAKANISHI, N ;
YOSHIOKA, T ;
KAWASHIMA, Y .
ANNALS OF THORACIC SURGERY, 1994, 58 (06) :1626-1630
[8]   THE RISK OF SMALL ST-JUDE AORTIC-VALVE PROSTHESES [J].
KRATZ, JM ;
SADE, RM ;
CRAWFORD, FA ;
CRUMBLEY, AJ ;
STROUD, MR .
ANNALS OF THORACIC SURGERY, 1994, 57 (05) :1114-1119
[9]   HYPOPLASIA OF AORTIC ROOT - PROBLEM OF AORTIC VALVE REPLACEMENT [J].
NICKS, R ;
CARTMILL, T ;
BERNSTEI.L .
THORAX, 1970, 25 (03) :339-&
[10]  
PAULIS RD, 1997, J THORAC CARDIOVASC, V113, P901