Structural performance of short concrete-filled steel tube columns with external and internal stiffening under axial compression

被引:25
作者
Alrebeh, Salih K. [1 ,2 ]
Ekmekyapar, Talha [1 ]
机构
[1] Gaziantep Univ, Dept Civil Engn, TR-27310 Gaziantep, Turkey
[2] Thi Qar Univ, Civil Engn Dept, Thi Qar 64001, Iraq
关键词
Concrete-filled steel tube; External reinforcing rings; Internal reinforcing bars; Axial strength; Axial stiffness; Ductility behavior; Confinement index; Short column; HIGH-STRENGTH CONCRETE; EXPERIMENTAL BEHAVIOR; STUB COLUMNS; DUCTILITY; TESTS; DESIGN; CONFINEMENT;
D O I
10.1016/j.istruc.2019.06.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
External confinement and internal stiffening have been widely adopted for strengthening concrete-filled steel tube (CFST) columns. This paper presents an attempt to study the possibility of combining the external confinement using reinforcing rings and the internal stiffening using reinforcing bars for strengthening CFST columns. In order to investigate the structural performance of the proposed combination method, a total of 18 specimens were tested under axial compression. These specimens were strengthened using three different methods: confinement in the form of external reinforcing rings (ERRs), stiffening in the form of internal reinforcing bars (IRBs), and a combination of both methods. For all tested specimens, the thickness of steel tube, outer diameter, and tube length were 4.15 mm, 114.3 mm, and 260 mm, respectively. CFST specimens were filled using self-compacting concrete (SCC) of normal compressive strength. The main parameters considered in the WA procedure are the spacing between the ERRs, the number of IRBs, and a combination of the ERRs spacing and the number of IRBs. The experimental results show that the proposed combination method is more effective to improve the structural performance of short CFST columns compared to using only ERRs or IRBs. Further improvement is achieved when the spacing between the ERRs decreases and the number of IRBs increases. The proposed combination method increases the compressive load-carrying capacity up to 27.2% and 57.4% compared to ERRs and IRBs, respectively. It deserves noting that the proposed combination method, ERRs, and IRBs improve the compressive load-carrying capacity up to 120.3%, 93.5%, and 40%, respectively, compared to the control specimen. In addition, specimens strengthened by the proposed combination method show an excellent ductility behavior.
引用
收藏
页码:702 / 716
页数:15
相关论文
共 60 条
  • [1] Behavior of Reinforced Lightweight Aggregate Concrete-filled Circular Steel Tube Columns Under Axial Loading
    Al-Eliwi, Baraa J. M.
    Ekmekyapar, Talha
    Al-Samaraie, Mohanad I. A.
    Dogru, M. Hanifi
    [J]. STRUCTURES, 2018, 16 : 101 - 111
  • [2] Evaluation of passive confinement in CFT columns
    Andrade de Oliveira, Walter Luiz
    De Nardin, Silvana
    de Cresce El Debs, Ana Lucia H.
    El Debs, Mounir Khalil
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (04) : 487 - 495
  • [3] [Anonymous], 2014, C39C39M14A ASTM INT
  • [4] [Anonymous], 2015, E8E8M13A ASTM INT
  • [5] Behaviour of thin-walled steel box sections with or without internal restraint
    Bridge, RQ
    O'Shea, MD
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1998, 47 (1-2) : 73 - 91
  • [6] British Standards I, 2005, Eurocode 3: Design of steel structures
  • [7] BSI British Standards Institution (BSI), 2004, Eurocode 2: 2004
  • [8] Axial strength of circular concrete-filled steel tube columns - DOE approach
    Chitawadagi, Manojkumar V.
    Narasimhan, Mattur C.
    Kulkarni, S. M.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (10) : 1248 - 1260
  • [9] Confinement effect of stiffened and unstiffened concrete-filled stainless steel tubular stub columns
    Dabaon, Mohamed
    El-Khoriby, Saher
    El-Boghdadi, Mahmoud
    Hassanein, Mostafa Fahmi
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2009, 65 (8-9) : 1846 - 1854
  • [10] Compressive strength of circular concrete filled steel tube columns
    Dundu, M.