Lamb Waves and Adaptive Beamforming for Aberration Correction in Medical Ultrasound Imaging

被引:13
|
作者
Mozaffarzadeh, Moein [1 ]
Minonzio, Claudio [1 ]
de Jong, Nico [1 ,2 ]
Verweij, Martin D. [1 ,2 ]
Hemm, Simone [3 ]
Daeichin, Verya [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Lab Med Imaging, NL-2628 CJ Delft, Netherlands
[2] Erasmus MC, Thoraxctr, Dept Biomed Engn, NL-3015 GD Rotterdam, Netherlands
[3] Univ Appl Sci & Arts Northwestern Switzerland, Sch Life Sci, Inst Med Engn & Med Informat, CH-4132 Muttenz, Switzerland
关键词
Slabs; Imaging; Ultrasonic imaging; Array signal processing; Skull; Probes; Acoustics; Adaptive beamforming; deep brain stimulation (DBS); Lamb waves; sound speed map; transcranial ultrasound imaging (TUI); TRANSCRANIAL ULTRASOUND; TIME-REVERSAL; BRAIN HELMET; PULSE-ECHO; SKULL; PHASE; TEMPERATURE; EXCITATION; ARTIFACTS; ALGORITHM;
D O I
10.1109/TUFFC.2020.3007345
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Phase aberration in transcranial ultrasound imaging (TUI) caused by the human skull leads to an inaccurate image reconstruction. In this article, we present a novel method for estimating the speed of sound and an adaptive beamforming technique for phase aberration correction in a flat polyvinylchloride (PVC) slab as a model for the human skull. First, the speed of sound of the PVC slab is found by extracting the overlapping quasi-longitudinal wave velocities of symmetrical Lamb waves in the frequency-wavenumber domain. Then, the thickness of the plate is determined by the echoes from its front and back side. Next, an adaptive beamforming method is developed, utilizing the measured sound speed map of the imaging medium. Finally, to minimize reverberation artifacts caused by strong scatterers (i.e., needles), a dual probe setup is proposed. In this setup, we image the medium from two opposite directions, and the final image can be the minimum intensity projection of the inherently co-registered images of the opposed probes. Our results confirm that the Lamb wave method estimates the longitudinal speed of the slab with an error of 3.5% and is independent of its shear wave speed. Benefiting from the acquired sound speed map, our adaptive beamformer reduces (in real time) a mislocation error of 3.1, caused by an 8 mm slab, to 0.1 mm. Finally, the dual probe configuration shows 7 dB improvement in removing reverberation artifacts of the needle, at the cost of only 2.4-dB contrast loss. The proposed image formation method can be used, e.g., to monitor deep brain stimulation procedures and localization of the electrode(s) deep inside the brain from two temporal bones on the sides of the human skull.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 50 条
  • [1] Lamb Waves and Adaptive Beamforming for Aberration Correction in Medical Ultrasound Imaging (vol 68, pg 84, 2021)
    Mozaffarzadeh, Moein
    Minonzio, Claudio
    de Jong, Nico
    Verweij, Martin D.
    Hemm, Simone
    Renaud, Guillaume
    Daeichin, Verya
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (02) : 352 - 353
  • [2] Phase Aberration Correction in Minimum Variance Beamforming of Ultrasound Imaging
    Ziksari, Mahsa Sotoodeh
    Asl, Babak Mohammadzadeh
    2015 23RD IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2015, : 23 - 26
  • [3] Adaptive Beamforming Algorithm for Medical Ultrasound Imaging
    Bao X.-R.
    Li Y.-Z.
    Su T.
    Zhang S.
    Li, Yu-Zhen (liyuzhen_1992@126.com), 2018, Northeast University (39): : 468 - 472and482
  • [4] Adaptive beamforming applied to medical ultrasound imaging
    Synnevag, Johan-Fredrik
    Austeng, Andreas
    Holm, Sverre
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (08) : 1606 - 1613
  • [5] Adaptive Beamforming for Array Imaging of Plate Structures Using Lamb Waves
    Engholm, Marcus
    Stepinski, Tadeusz
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (12) : 2712 - 2724
  • [6] Combined phase screen aberration correction and minimum variance beamforming in medical ultrasound
    Ziksari, Mahsa Sotoodeh
    Asl, Babak Mohammadzadeh
    ULTRASONICS, 2017, 75 : 71 - 79
  • [7] New robust adaptive beamforming for imaging damages scattering coherent Lamb waves
    Li, Dan
    Liu, Yuxuan
    Yang, Tingxuan
    Li, Ying
    Zhang, Jian Qiu
    Ta, Dean
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2025,
  • [8] Minimum variance adaptive beamforming applied to medical ultrasound imaging
    Synnevag, JF
    Austeng, A
    Holm, S
    2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 1199 - 1202
  • [9] PLANE WAVE MEDICAL ULTRASOUND IMAGING USING ADAPTIVE BEAMFORMING
    Holfort, Iben Kraglund
    Gran, Fredrik
    Jensen, Jorgen Arendt
    2008 IEEE SENSOR ARRAY AND MULTICHANNEL SIGNAL PROCESSING WORKSHOP, 2008, : 288 - +
  • [10] Adaptive beamforming with automatic diagonal loading in medical ultrasound imaging
    Salari, Ali
    Asl, Babak Mohammadzadeh
    2018 25TH IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING AND 2018 3RD INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2018, : 120 - 125