The stability and calibration of water vapor isotope ratio measurements during long-term deployments

被引:49
|
作者
Bailey, A. [1 ,2 ]
Noone, D. [1 ,2 ,3 ]
Berkelhammer, M. [4 ]
Steen-Larsen, H. C. [5 ]
Sato, P. [6 ]
机构
[1] Univ Colorado, Dept Atmospher & Ocean Sci, Boulder, CO 80309 USA
[2] Univ Colorado, Cooperat Inst Res Environm Sci, Boulder, CO 80309 USA
[3] Oregon State Univ, Coll Earth Ocean & Atmospher Sci, Corvallis, OR 97331 USA
[4] Univ Illinois, Dept Earth & Environm Sci, Chicago, IL USA
[5] Lab Sci Climat & Environm, Gif Sur Yvette, France
[6] NOAA, Joint Inst Marine & Atmospher Res, Hilo, HI USA
基金
美国国家科学基金会;
关键词
DEUTERIUM EXCESS; DELTA-O-18; MEASUREMENTS; BOUNDARY-LAYER; IN-SITU; DELTA-H-2; HYDROGEN; OXYGEN; PRECIPITATION;
D O I
10.5194/amt-8-4521-2015
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
With the recent advent of commercial laser absorption spectrometers, field studies measuring stable isotope ratios of hydrogen and oxygen in water vapor have proliferated. These pioneering analyses have provided invaluable feedback about best strategies for optimizing instrumental accuracy, yet questions still remain about instrument performance and calibration approaches for multi-year field deployments. With clear scientific potential for using these instruments to carry out monitoring of the hydrological cycle, this study examines the long-term stability of the isotopic biases associated with three cavity-enhanced laser absorption spectrometers - calibrated with different systems and approaches - at two remote field sites: Mauna Loa Observatory, Hawaii, USA, and Greenland Environmental Observatory, Summit, Greenland. The analysis pays particular attention to the stability of measurement dependencies on water vapor concentration and also evaluates whether these so-called concentration dependences are sensitive to statistical curve-fitting choices or measurement hysteresis. The results suggest evidence of monthly-to-seasonal concentration-dependence variability - which likely stems from low signal-to-noise at the humidity-range extremes - but no long-term directional drift. At Mauna Loa, where the isotopic analyzer is calibrated by injection of liquid water standards into a vaporizer, the largest source of inaccuracy in characterizing the concentration dependence stems from an insufficient density of calibration points at low water vapor volume mixing ratios. In comparison, at Summit, the largest source of inaccuracy is measurement hysteresis associated with interactions between the reference vapor, generated by a custom dew point generator, and the sample tubing. Nevertheless, prediction errors associated with correcting the concentration dependence are small compared to total measurement uncertainty. At both sites, changes in measurement repeatability that are not predicted by long-term linear drift estimates are a larger source of error, highlighting the importance of measuring isotopic standards with minimal or well characterized drift at regular intervals. Challenges in monitoring isotopic drift are discussed in light of the different calibration systems evaluated.
引用
收藏
页码:4521 / 4538
页数:18
相关论文
共 50 条
  • [21] Localization and navigation of the CoBots over long-term deployments
    Biswas, Joydeep
    Veloso, Manuela M.
    INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2013, 32 (14): : 1679 - 1694
  • [22] The need for accurate long-term measurements of water vapor in the upper troposphere and lower stratosphere with global coverage
    Mueller, Rolf
    Kunz, Anne
    Hurst, Dale F.
    Rolf, Christian
    Kraemer, Martina
    Riese, Martin
    EARTHS FUTURE, 2016, 4 (02): : 25 - 32
  • [23] Water-vapor isotope ratio measurements in air with a quantum-cascade laser spectrometer
    Joly, L
    Zéninari, V
    Parvitte, B
    Courtois, D
    Durry, G
    OPTICS LETTERS, 2006, 31 (02) : 143 - 145
  • [24] Long-term stability of hydrogen isotope ratios in hydrated volcanic glass
    Cassel, Elizabeth J.
    Breecker, Daniel O.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2017, 200 : 67 - 86
  • [25] Long-term stability and water vapor induced degradation of physico-chemical properties of XPS and PF
    Leem, Yoobin
    Kitagaki, Ryoma
    Ishida, Takato
    Hagihara, Hideaki
    DEVELOPMENTS IN THE BUILT ENVIRONMENT, 2024, 18
  • [26] On the long-term stability of microwave radiometers using noise diodes for calibration
    Brown, Shannon T.
    Desai, Shailen
    Lu, Wenwen
    Tanner, Alan B.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2007, 45 (07): : 1908 - 1920
  • [27] LONG-TERM CALIBRATION STABILITY OF A RADIO ASTRONOMICAL PHASED ARRAY FEED
    Elmer, Michael
    Jeffs, Brian D.
    Warnick, Karl F.
    ASTRONOMICAL JOURNAL, 2013, 145 (01):
  • [28] Generation and Long-Term Stability of Ultrafine Bubbles in Water
    Tanaka, Shunya
    Terasaka, Koichi
    Fujioka, Satoko
    CHEMIE INGENIEUR TECHNIK, 2021, 93 (1-2) : 168 - 179
  • [29] Long-Term Stability Metrics of Photoelectrochemical Water Splitting
    Vanka, Srinivas
    Zeng, Guosong
    Deutsch, Todd G.
    Toma, Francesca Maria
    Mi, Zetian
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [30] Determination of clumped isotopes in carbonate using isotope ratio mass spectrometer: Effects of extraction potential and long-term stability
    Cui, Linlin
    Wang, Xu
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2014, 372 : 46 - 50