The stability and calibration of water vapor isotope ratio measurements during long-term deployments

被引:49
|
作者
Bailey, A. [1 ,2 ]
Noone, D. [1 ,2 ,3 ]
Berkelhammer, M. [4 ]
Steen-Larsen, H. C. [5 ]
Sato, P. [6 ]
机构
[1] Univ Colorado, Dept Atmospher & Ocean Sci, Boulder, CO 80309 USA
[2] Univ Colorado, Cooperat Inst Res Environm Sci, Boulder, CO 80309 USA
[3] Oregon State Univ, Coll Earth Ocean & Atmospher Sci, Corvallis, OR 97331 USA
[4] Univ Illinois, Dept Earth & Environm Sci, Chicago, IL USA
[5] Lab Sci Climat & Environm, Gif Sur Yvette, France
[6] NOAA, Joint Inst Marine & Atmospher Res, Hilo, HI USA
基金
美国国家科学基金会;
关键词
DEUTERIUM EXCESS; DELTA-O-18; MEASUREMENTS; BOUNDARY-LAYER; IN-SITU; DELTA-H-2; HYDROGEN; OXYGEN; PRECIPITATION;
D O I
10.5194/amt-8-4521-2015
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
With the recent advent of commercial laser absorption spectrometers, field studies measuring stable isotope ratios of hydrogen and oxygen in water vapor have proliferated. These pioneering analyses have provided invaluable feedback about best strategies for optimizing instrumental accuracy, yet questions still remain about instrument performance and calibration approaches for multi-year field deployments. With clear scientific potential for using these instruments to carry out monitoring of the hydrological cycle, this study examines the long-term stability of the isotopic biases associated with three cavity-enhanced laser absorption spectrometers - calibrated with different systems and approaches - at two remote field sites: Mauna Loa Observatory, Hawaii, USA, and Greenland Environmental Observatory, Summit, Greenland. The analysis pays particular attention to the stability of measurement dependencies on water vapor concentration and also evaluates whether these so-called concentration dependences are sensitive to statistical curve-fitting choices or measurement hysteresis. The results suggest evidence of monthly-to-seasonal concentration-dependence variability - which likely stems from low signal-to-noise at the humidity-range extremes - but no long-term directional drift. At Mauna Loa, where the isotopic analyzer is calibrated by injection of liquid water standards into a vaporizer, the largest source of inaccuracy in characterizing the concentration dependence stems from an insufficient density of calibration points at low water vapor volume mixing ratios. In comparison, at Summit, the largest source of inaccuracy is measurement hysteresis associated with interactions between the reference vapor, generated by a custom dew point generator, and the sample tubing. Nevertheless, prediction errors associated with correcting the concentration dependence are small compared to total measurement uncertainty. At both sites, changes in measurement repeatability that are not predicted by long-term linear drift estimates are a larger source of error, highlighting the importance of measuring isotopic standards with minimal or well characterized drift at regular intervals. Challenges in monitoring isotopic drift are discussed in light of the different calibration systems evaluated.
引用
收藏
页码:4521 / 4538
页数:18
相关论文
共 50 条
  • [1] Accuracy of Raman lidar water vapor calibration and its applicability to long-term measurements
    Leblanc, Thierry
    McDermid, I. Stuart
    APPLIED OPTICS, 2008, 47 (30) : 5592 - 5603
  • [2] Comments on "Accuracy of Raman lidar water vapor calibration and its applicability to long-term measurements"
    Whiteman, David N.
    Venable, Demetrius
    Landulfo, Eduardo
    APPLIED OPTICS, 2011, 50 (15) : 2170 - 2176
  • [3] A versatile water vapor generation module for vapor isotope calibration and liquid isotope measurements
    Steen-Larsen, Hans Christian
    Zannoni, Daniele
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2024, 17 (14) : 4391 - 4409
  • [4] A Microdrop Generator for the Calibration of a Water Vapor Isotope Ratio Spectrometer
    Iannone, Rosario Q.
    Romanini, Daniele
    Kassi, Samir
    Meijer, Harro A. J.
    Kerstel, Erik R. Th.
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2009, 26 (07) : 1275 - 1288
  • [5] Long-term stability of rhinomanometer calibration
    Sipila, J
    Suonpaa, J
    JOURNAL OF OTOLARYNGOLOGY, 1997, 26 (01): : 49 - 52
  • [6] The calibration of Si isotope ratio measurements
    Mana, G.
    Rienitz, O.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 291 (1-2) : 55 - 60
  • [7] Lead isotope ratio measurements by ICP-MS: Accuracy, precision, and long-term drift
    Halicz, L
    Erel, Y
    Veron, A
    ATOMIC SPECTROSCOPY, 1996, 17 (05) : 186 - 189
  • [8] On the long-term stability of calibration standards in different matrices
    Kandic, A.
    Vukanac, I.
    Djurasevic, M.
    Novkovic, D.
    Seslak, B.
    Milosevic, Z.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 1860 - 1862
  • [9] Reply to "Comments on Accuracy of Raman lidar water vapor calibration and its applicability to long-term measurements" by Whiteman et al.
    Leblanc, Thierry
    McDermid, I. Stuart
    APPLIED OPTICS, 2011, 50 (15) : 2177 - 2178
  • [10] LONG-TERM STABILITY MEASUREMENTS ON MAGNETIC FLUIDS
    BISSELL, PR
    CHANTRELL, RW
    SPRATT, GWD
    BATES, PA
    OGRADY, KD
    IEEE TRANSACTIONS ON MAGNETICS, 1984, 20 (05) : 1738 - 1740