Three-dimensional echocardiography for assessment of mitral valve stenosis

被引:13
作者
Zamorano, Jose [1 ]
Alberto de Agustin, Jose [1 ]
机构
[1] Hosp Clin San Carlos, Unidad Imagen Cardiovasc, Madrid 28040, Spain
关键词
mitral stenosis; planimetry; three-dimensional echocardiography; PRESSURE HALF-TIME; REAL-TIME; AORTIC-STENOSIS; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; QUANTITATIVE ASSESSMENT; AREA; ACCURACY; ORIFICE; COMMISSUROTOMY; VALVULOPLASTY;
D O I
10.1097/HCO.0b013e32832e165b
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose of review Since the last few years, three-dimensional echocardiography (3DE) has become an accurate tool for mitral stenosis assessment. We will review the latest developments of 3DE in this matter. Recent findings Accuracy of 3DE planimetry is superior to the accuracy of the invasive Gorlin's method for mitral valve area (MVA) measurements when a median value obtained from two-dimensional planimetry, pressure half-time, and proximal isovelocity surface area method is used as the gold standard. 3DE improves MVA measurement particularly in less experienced operators compared with experienced operators. 3DE also improves the measurement of MVA in patients with calcific mitral stenosis by means of colour planimetry of the flow stream. Comparison of mitral valve volumes measured by 3DE in patients with critical and without critical stenosis has shown significantly larger volumes in patients with critical stenosis. Summary Currently, there is sufficient evidence that 3DE is superior to two-dimensional echocardiography and may be routinely used in the quantification of the MVA in mitral stenosis. In the coming years, 3DE might replace Gorlin's method as the gold standard for MVA quantification and may eventually make cardiac catheterization unnecessary.
引用
收藏
页码:415 / 419
页数:5
相关论文
共 34 条
[31]  
WILKINS GT, 1988, BRIT HEART J, V60, P299
[32]   Comparison of accuracy of mitral valve-area in mitral stenosis by real-time, three-dimensional echocardiography versus two-dimensional echocardiography versus Doppler pressure half-time [J].
Xie, MX ;
Wang, XF ;
Cheng, TO ;
Wang, J ;
Lu, Q .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (12) :1496-1499
[33]   Non-invasive assessment of mitral valve area during percutaneous balloon mitral vaivuloplasty: role of real-time 3D echocardiography [J].
Zamorano, J ;
de Isla, LP ;
Sugeng, L ;
Cordeiro, P ;
Rodrigo, JL ;
Almeria, C ;
Weinert, L ;
Feldman, T ;
Macaya, C ;
Lang, RM ;
Antolin, RH .
EUROPEAN HEART JOURNAL, 2004, 25 (23) :2086-2091
[34]   Real-time three-dimensional echocardiography for rheumatic mitral valve stenosis evaluation -: An accurate and novel approach [J].
Zamorano, J ;
Cordeiro, P ;
Sugeng, L ;
de Isla, LP ;
Weinert, L ;
Macaya, C ;
Rodríguez, E ;
Lang, RM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (11) :2091-2096