Three-dimensional echocardiography for assessment of mitral valve stenosis

被引:13
作者
Zamorano, Jose [1 ]
Alberto de Agustin, Jose [1 ]
机构
[1] Hosp Clin San Carlos, Unidad Imagen Cardiovasc, Madrid 28040, Spain
关键词
mitral stenosis; planimetry; three-dimensional echocardiography; PRESSURE HALF-TIME; REAL-TIME; AORTIC-STENOSIS; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; QUANTITATIVE ASSESSMENT; AREA; ACCURACY; ORIFICE; COMMISSUROTOMY; VALVULOPLASTY;
D O I
10.1097/HCO.0b013e32832e165b
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose of review Since the last few years, three-dimensional echocardiography (3DE) has become an accurate tool for mitral stenosis assessment. We will review the latest developments of 3DE in this matter. Recent findings Accuracy of 3DE planimetry is superior to the accuracy of the invasive Gorlin's method for mitral valve area (MVA) measurements when a median value obtained from two-dimensional planimetry, pressure half-time, and proximal isovelocity surface area method is used as the gold standard. 3DE improves MVA measurement particularly in less experienced operators compared with experienced operators. 3DE also improves the measurement of MVA in patients with calcific mitral stenosis by means of colour planimetry of the flow stream. Comparison of mitral valve volumes measured by 3DE in patients with critical and without critical stenosis has shown significantly larger volumes in patients with critical stenosis. Summary Currently, there is sufficient evidence that 3DE is superior to two-dimensional echocardiography and may be routinely used in the quantification of the MVA in mitral stenosis. In the coming years, 3DE might replace Gorlin's method as the gold standard for MVA quantification and may eventually make cardiac catheterization unnecessary.
引用
收藏
页码:415 / 419
页数:5
相关论文
共 34 条
[1]   Evaluation of rheumatic tricuspid valve stenosis by real-time three-dimensional echocardiography [J].
Anwar, Ashraf M. ;
Geleijnse, Marcel L. ;
Soliman, Osama I. I. ;
McGhie, Jackie S. ;
Nemes, Attila ;
ten Cate, Folkert J. .
HEART, 2007, 93 (03) :363-364
[2]   Utility of three-dimensional echocardiography during balloon mitral valvuloplasty [J].
Applebaum, RM ;
Kasliwal, RR ;
Kanojia, A ;
Seth, A ;
Bhandari, S ;
Trehan, N ;
Winer, HE ;
Tunick, PA ;
Kronzon, I .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) :1405-1409
[3]   Improved assessment of mitral valve stenosis by volumetric real-time three-dimensional echocardiography [J].
Binder, TM ;
Rosenhek, R ;
Porenta, G ;
Maurer, G ;
Baumgartner, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) :1355-1361
[4]   Comparison of accuracy of aortic valve area assessment in aortic stenosis by real time three-dimensional echocardiography in biplane mode versus two-dimensional transthoracic and transesophageal echocardiography [J].
Blot-Souletie, Nathalie ;
Hebrard, Aurelien ;
Acar, Philippe ;
Carrie, Didier ;
Puel, Jacques .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (10) :1065-1072
[5]   Assessing mitral valve area and orifice geometry in calcific mitral stenosis: A new solution by real-time three-dimensional echocardiography [J].
Chu, John W. ;
Levine, Robert A. ;
Chua, Sarah ;
Poh, Kian-Keong ;
Morris, Eleanor ;
Hua, Lanqi ;
Ton-Nu, Thanh-Thao ;
Hung, Judy .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (09) :1006-1009
[6]   The use of three-dimensional echocardiography for the evaluation of and treatment of mitral stenosis [J].
de Agustin, Jose A. ;
Nanda, Navin C. ;
Gill, Edward A. ;
Perez de Isla, Leopoldo ;
Zamorano, Jose L. .
CARDIOLOGY CLINICS, 2007, 25 (02) :311-+
[7]   Quantification of aortic valve area using three-dimensional echocardiography [J].
de Isla, Leopoldo Perez ;
Zamorano, Jose ;
de la Yglesia, Rocio Perez ;
Cioccarelli, Sara ;
Almeria, Carlos ;
Rodrigo, Jose L. ;
Aubele, Ada L. ;
Herrera, Dionisio ;
Mataix, Luis ;
Serra, Viviana ;
Macaya, Carlos .
REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (05) :494-500
[8]   Which method should be the reference method to evaluate the severity of rheumatic mitral stenosis? Gorlin's method versus 3D-echo [J].
de Isla, Leopoldo Perez ;
Casanova, Carlos ;
Almeria, Carlos ;
Rodrigo, Jose Luis ;
Cordeiro, Pedro ;
Mataix, Luis ;
Aubele, Ada Lia ;
Lang, Roberto ;
Zamorano, Jose Luis .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2007, 8 (06) :470-473
[9]   Measurement of mitral valve area in mitral stenosis: Four echocardiographic methods compared with direct measurement of anatomic orifices [J].
Faletra, F ;
Pezzano, A ;
Fusco, R ;
Mantero, A ;
Corno, R ;
Crivellaro, W ;
DeChiara, F ;
Vitali, E ;
Gordini, V ;
Magnani, P ;
Pezzano, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) :1190-1197
[10]  
Faletra F, 2005, Heart, V91, P499, DOI 10.1136/hrt.2004.041459