Determination of carnitine and acylcarnitines in plasma by high-performance liquid chromatography/electrospray ionization ion trap tandem mass spectrometry

被引:67
|
作者
Vernez, L
Wenk, M
Krähenbühl, S
机构
[1] Univ Basel Hosp, Div Clin Pharmacol & Toxicol, CH-4031 Basel, Switzerland
[2] Univ Basel Hosp, Dept Res, CH-4031 Basel, Switzerland
关键词
D O I
10.1002/rcm.1470
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatography/mass spectrometry method was developed for the determination of carnitine, its biosynthetic precursor butyrobetaine, and eight acylcarnitines in plasma. The procedure includes a solid-phase extraction for carnitine and short- and medium-chain acylcarnitines, and a liquid-liquid extraction for protein-bound long-chain acylcarnitines, followed by separation on a reversed-phase column in the presence of a volatile ion-pairing reagent. Detection was achieved using an ion-trap mass spectrometer run in the tandem mass spectrometry (MS/MS) mode. The choice of the matrix for calibrators, used for quantification of these endogenous compounds, was also investigated. Validation was performed for standard quality controls diluted with 4% bovine serum albumin solution and for spiked plasma quality control samples at concentrations between 0.5 and 80 mumol/L, depending on the compound. Intra- and inter-day precisions for the determination of carnitine were below 3.4% and accuracies were between 95.2 and 109.0%. Application of the method to the diagnosis of pathological acylcarnitine profiles of metabolic disorders in a patient suffering from methylmalonic aciduria is presented. The method allows quantification of carnitine, butyrobetaine, acetylcarnitine and propionylcarnitine, and semi-quantitative analysis of medium- and long-chain acylcarnitines. In contrast with other methods, no derivatization step is needed. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1233 / 1238
页数:6
相关论文
共 50 条
  • [41] Identification of Ceftiofur Oxidation Products by High-Performance Liquid Chromatography/Electrospray Ionization/Tandem Mass Spectrometry
    Lim, Young-Hee
    Park, Deok-Hie
    Youn, Yeu Young
    Kim, Kyung Hoon
    Cho, Hye-Sung
    MASS SPECTROMETRY LETTERS, 2011, 2 (01) : 16 - 19
  • [42] Improved characterization of tomato polyphenols using liquid chromatography/electrospray ionization linear ion trap quadrupole Orbitrap mass spectrometry and liquid chromatography/electrospray ionization tandem mass spectrometry
    Vallverdu-Queralt, Anna
    Jauregui, Olga
    Medina-Remon, Alexander
    Andres-Lacueva, Cristina
    Lamuela-Raventos, Rosa M.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (20) : 2986 - 2992
  • [43] Quantification of plasma carnitine and acylcarnitines by high-performance liquid chromatography-tandem mass spectrometry using online solid-phase extraction
    Réjane Morand
    Massimiliano Donzelli
    Manuel Haschke
    Stephan Krähenbühl
    Analytical and Bioanalytical Chemistry, 2013, 405 : 8829 - 8836
  • [44] Determination of lovastatin in human plasma by ultra-performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Wang, Dong
    Wang, Dongmei
    Qin, Feng
    Chen, Lingyun
    Li, Famei
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (05) : 511 - 518
  • [45] Quantification of plasma carnitine and acylcarnitines by high-performance liquid chromatography-tandem mass spectrometry using online solid-phase extraction
    Morand, Rejane
    Donzelli, Massimiliano
    Haschke, Manuel
    Kraehenbuehl, Stephan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (27) : 8829 - 8836
  • [46] Determination of persistent tetracycline residues in soil fertilized with liquid manure by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry
    Hamscher, G
    Sczesny, S
    Höper, H
    Nau, H
    ANALYTICAL CHEMISTRY, 2002, 74 (07) : 1509 - 1518
  • [47] Determination of bencycloquidium bromide in dog plasma by liquid chromatography with electrospray ionization tandem mass spectrometry
    Jiang, Bo
    Ruan, Zourong
    Lou, Honggang
    Dong, Xinwei
    Xie, Qiangmin
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (05) : 490 - 496
  • [48] Quantitative determination of rosuvastatin in human plasma by liquid chromatography with electrospray ionization tandem mass spectrometry
    Xu, Dong-Hang
    Ruan, Zou-Rong
    Zhou, Quan
    Yuan, Hong
    Jiang, Bo
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (16) : 2369 - 2375
  • [49] Determination of bulleyaconitine A in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Weng, WY
    Xu, HN
    Huang, JM
    Wang, GQ
    Shen, T
    Zhang, JF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 315 - 320
  • [50] Determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Salem, II
    Idrees, J
    Al Tamimi, JI
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 799 (01): : 103 - 109