Cervical ultrasonography compared with manual examination as a predictor of preterm delivery

被引:181
作者
Berghella, V
Tolosa, JE
Kuhlman, K
Weiner, S
Bolognese, RJ
Wapner, RJ
机构
[1] PENN HOSP,DEPT OBSTET & GYNECOL,PHILADELPHIA,PA 19107
[2] NICHHD,PERINATOL RES BRANCH,BETHESDA,MD 20892
关键词
cervix uteri; preterm delivery; risk prediction; ultrasonography;
D O I
10.1016/S0002-9378(97)70259-X
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: Our purpose was to compare the accuracy of ultrasonographic and manual cervical examinations for the prediction of preterm delivery. STUDY DESIGN: One hundred two singleton pregnancies at high risk for preterm delivery were followed up prospectively from 14 to 30 weeks with both serial cervical ultrasonography measurements and manual examinations of the length of the cervix. The primary outcome studied was preterm (<35 weeks) delivery. RESULTS: Excluding six induced preterm deliveries, 96 pregnancies were analyzed. The mean cervical length measured by ultrasonography was 20.6 mm in pregnancies delivered preterm (n = 17) and 31.3 mm in pregnancies delivered at term (n = 79) (p = 0.003); the mean cervical lengths measured by manual examination were 16.1 mm and 18.6 mm in the same preterm and term pregnancies, respectively (not significant). The sixteenth-and twentieth-week ultrasonographic cervical lengths predicted preterm delivery most accurately Go < 0.0005). The 25th percentiles of ultrasonographic (25 mm) and manual (16 mm) cervical lengths showed relative risks for preterm delivery of 4.8 (95% confidence interval 2.1 to 11.1, p = 0.0004) and 2.0 (95% confidence interval 0.5 to 4.7, p = 0.1), respectively; sensitivity, specificity, and positive and negative predictive values were 59%, 85%, 45%, 91%, and 41%, 77%, 28%, and 86%, respectively. CONCLUSION: Cervical length measured by ultrasonography is a better predictor of preterm delivery than is cervical length measured by manual examination. Cervical ultrasonography in patients at high risk for preterm birth seems to be most predictive of preterm delivery when it is performed between 14 and 22 weeks' gestation.
引用
收藏
页码:723 / 730
页数:8
相关论文
共 32 条
  • [1] PREDICTION OF RISK FOR PRETERM DELIVERY BY ULTRASONOGRAPHIC MEASUREMENT OF CERVICAL LENGTH
    ANDERSEN, HF
    NUGENT, CE
    WANTY, SD
    HAYASHI, RH
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1990, 163 (03) : 859 - 867
  • [2] TRANSVAGINAL AND TRANSABDOMINAL ULTRASONOGRAPHY OF THE UTERINE CERVIX DURING PREGNANCY
    ANDERSEN, HF
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 1991, 19 (02) : 77 - 83
  • [3] AYERS JWT, 1988, OBSTET GYNECOL, V71, P939
  • [4] PREDICTION OF PRETERM DELIVERY - IS IT SUBSTANTIALLY IMPROVED BY ROUTINE VAGINAL EXAMINATIONS
    BLONDEL, B
    LECOUTOUR, X
    KAMINSKI, M
    CHAVIGNY, C
    BREART, G
    SUREAU, C
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1990, 162 (04) : 1042 - 1048
  • [5] SONOGRAPHIC APPEARANCE OF THE UTERINE CERVIX IN PREGNANCY - THE VERTICAL CERVIX
    BOWIE, JD
    ANDREOTTI, RF
    ROSENBERG, ER
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 140 (04) : 737 - 740
  • [6] Cohen J., 1969, STAT POWER ANAL BEHA
  • [7] ELECTIVE CERVICAL SUTURE OF TWIN PREGNANCIES DIAGNOSED ULTRASONICALLY IN THE 1ST TRIMESTER FOLLOWING INDUCED OVULATION
    DOR, J
    SHALEV, J
    MASHIACH, S
    BLANKSTEIN, J
    SERR, DM
    [J]. GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1982, 13 (01) : 55 - 60
  • [8] FLOYD WS, 1961, OBSTET GYNECOL, V18, P380
  • [9] Preterm prediction study: Fetal fibronectin testing and spontaneous preterm birth
    Goldenberg, RL
    Mercer, BM
    Meis, PJ
    Cooper, RL
    Das, A
    McNellis, D
    [J]. OBSTETRICS AND GYNECOLOGY, 1996, 87 (05) : 643 - 648
  • [10] GOLDENBERG RL, 1996, AM J OBSTET GYNECOL, V175, P1049