Study on Acoustic Catheter of Boiler Tube Leakage Monitoring Systems

被引:0
作者
Lv, Yongxing [1 ]
Yan, Chenshuai [1 ]
机构
[1] State Nucl Elect Power Planning Design & Res Inst, Beijing 100095, Peoples R China
来源
RENEWABLE ENERGY AND ENVIRONMENTAL TECHNOLOGY, PTS 1-6 | 2014年 / 448-453卷
关键词
power station; boiler; four tube leakage; resonance cavity; acoustic catheter; SENSOR FAULT-DETECTION; DIAGNOSIS; PCA;
D O I
10.4028/www.scientific.net/AMM.448-453.3457
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Boiler tube leakage is the major reason of affecting the safe operation of the unit now, there are 3 methods of the "four tube" leakage detection: Traditional method, filtering method and acoustic spectrum analysis, acoustic spectrum analysis is the common method, but this method have low sensitivity and the sensor damage easily. Therewith, designed the special acoustic catheter with acoustic resonance cavity type, proved by experiments, the acoustic catheter with acoustic resonance cavity type can enhance leakage sound, can accurately extract leakage signals, has high sensitivity, and can avoid the effect of sensor by fire and hot-gas when the furnace is in positive pressure situation, reduce the installation and maintenance costs of the boiler tube leakage monitor system.