Biomechanical Effects of Diameters of Implant Body and Implant Platform in Bone Strain around an Immediately Loaded Dental Implant with Platform Switching Concept

被引:4
作者
Lung, Hsuan [1 ,2 ,3 ]
Hsu, Jui-Ting [4 ,5 ]
Wu, Aaron Yu-Jen [1 ,2 ]
Huang, Heng-Li [4 ,5 ]
机构
[1] Chang Gung Mem Hosp, Dept Dent, Kaohsiung 833, Taiwan
[2] Chang Gung Univ, Coll Med, Kaohsiung 833, Taiwan
[3] Univ Calif San Francisco, Sch Dent, San Francisco, CA 94143 USA
[4] China Med Univ, Sch Dent, Taichung 404, Taiwan
[5] Asia Univ, Dept Bioinformat & Med Engn, Taichung 413, Taiwan
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 10期
关键词
implant diameter; platform switching; immediately loaded dental implant; bone strain; strain gauge analysis; STRESS-DISTRIBUTION; LENGTH; INTERFACE; STABILITY; DENTISTRY;
D O I
10.3390/app9101998
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Dental implants designed with platform switching have been used clinically to reduce crestal bone resorption. The aim of this study was to determine the biomechanical effects of loading types, diameter of platform, and implant diameter in bone strain around immediately loaded implants with platform switching concept. Platform-switching features of dental implants with various diameters of implant body and implant platform (named as RP5.0, RP4.3, and NP3.5) were inserted into artificial bone blocks. The initial implant stability was confirmed using a Periotest device before the loading test. Rosette strain gauges were placed on the alveolar region around the implants, and peak values of the bone strain during a 190-N vertical load or 30-degree lateral load were measured by a data acquisition system. The Kruskal-Wallis test and post-hoc pairwise comparisons were performed as statistical analyses. The median Periotest values of the RP5.0, RP4.3, and NP3.5 implants ranged from -6.59 to -7.34. The RP5.0 implant always showed the lowest bone strain around the implant, regardless of whether a vertical or lateral load was applied. Relative to the RP4.3 and NP3.5 implants, the RP4.3 implant produced a higher bone strain (by approximately 8%) under a vertical load but a lower bone strain (by approximately 25%) under a lateral load. This study confirmed that using a wider implant could relieve the bone strain around an immediately loaded implant with platform switching concept especially under lateral loading.
引用
收藏
页数:9
相关论文
共 34 条
  • [1] A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment
    Alsaadi, Ghada
    Quirynen, Marc
    Michiels, Katleen
    Jacobs, Reinhilde
    van Steenberghe, Daniel
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (04) : 359 - 366
  • [2] Platform Switching for Marginal Bone Preservation Around Dental implants: A Systematic Review and Meta-Analysis
    Atieh, Momen A.
    Ibrahim, Hadeel M.
    Atieh, Ahmad H.
    [J]. JOURNAL OF PERIODONTOLOGY, 2010, 81 (10) : 1350 - 1366
  • [3] Babbush Charles A, 2012, Implant Dent, V21, P28, DOI 10.1097/ID.0b013e3182344fce
  • [4] THE INFLUENCE OF IMPLANT DIAMETER AND LENGTH ON STRESS DISTRIBUTION OF OSSEOINTEGRATED IMPLANTS RELATED TO CRESTAL BONE GEOMETRY: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS
    Baggi, Luigi
    Cappelloni, Ilaria
    Di Girolamo, Michele
    Maceri, Franco
    Vairo, Giuseppe
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (06) : 422 - 431
  • [5] Immediate Restoration of NobelActive Implants Placed Into Fresh Extraction Sites in the Anterior Maxilla
    Bell, Christopher
    Bell, Robert E.
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (04) : 455 - 458
  • [6] Brunski JB, 2000, INT J ORAL MAX IMPL, V15, P15
  • [7] Platform switching and marginal bone-level alterations: the results of a randomized-controlled trial
    Canullo, Luigi
    Fedele, Giampiero Rossi
    Iannello, Giuliano
    Jepsen, Soren
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (01) : 115 - 121
  • [8] Fem and Von Mises Analysis of OSSTEM (R) Dental Implant Structural Components: Evaluation of Different Direction Dynamic Loads
    Cervino, Gabriele
    Romeo, Umberto
    Lauritano, Floriana
    Bramanti, Ennio
    Fiorillo, Luca
    D'Amico, Cesare
    Milone, Dario
    Laino, Luigi
    Campolongo, Francesco
    Rapisarda, Silvia
    Cicciu, Marco
    [J]. OPEN DENTISTRY JOURNAL, 2018, 12 : 219 - 229
  • [9] Chang CL, 2010, INT J ORAL MAX IMPL, V25, P295
  • [10] EFFECT OF IMPLANT DESIGN ON INITIAL STABILITY OF TAPERED IMPLANTS
    Chong, Linus
    Khocht, Ahmed
    Suzuki, Jon B.
    Gaughan, John
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2009, 35 (03) : 130 - 135