Thickness Measurements of Donor Posterior Disks After Descemet Stripping Endothelial Keratoplasty With Anterior Segment Optical Coherence Tomography

被引:40
作者
Nieuwendaal, Carla P. [1 ]
van Velthoven, Mirjam E. J. [1 ]
Biallosterski, Carine [1 ]
van der Meulen, Ivanka J. E. [1 ]
Lapid-Gortzak, Ruth [1 ]
Melles, Gerrit R. J. [2 ]
Verbraak, Frank D. [1 ,3 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Ophthalmol, NL-1105 AZ Amsterdam, Netherlands
[2] Netherlands Inst Innovat Ocular Surg, Rotterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Ctr Laser, NL-1105 AZ Amsterdam, Netherlands
关键词
Descemet stripping endothelial keratoplasty; optical coherence tomography; donor posterior disk; corneal thickness; LAMELLAR KERATOPLASTY; ULTRASOUND PACHYMETRY; CORNEAL THICKNESS; REPRODUCIBILITY; MEMBRANE; EYES;
D O I
10.1097/ICO.0b013e318189135f
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate donor posterior disk thickness measured with anterior segment optical coherence tomography after Descemet stripping endothelial keratoplasty. Methods: Fifteen patients (17 eyes) after Descemet stripping endothelial keratoplasty, using manually dissected donor posterior disks, were measured with the Visante anterior segment optical coherence tomography (Carl Zeiss Meditec Inc, Dublin, CA). Optical coherence tomography scans were made in a radial pattern, 45 degrees apart, starting in the horizontal axis. Thickness measurements of the donor posterior disks were taken centrally and at fixed radii toward the periphery and were correlated to postoperative change in spherical equivalent (SE), best-corrected visual acuity (BCVA, in Snellen), and improvement in BCVA. Results: Median BCVA was 20/30 (range 20/60-20/20) post-operatively. Median postoperative improvement in BCVA was 4 lines (range 1-11). Median follow-up time was 15.5 months (range 6-32 months). Median postoperative change in SE was -0.25 diopters (range -4.25 to +3.00 diopters). Median central disk thickness was 128.3 mu m (range 55-181 mu m) and increased significantly toward the periphery: median disk thickness at the 1.5 mm radius was 140.8 mu m (range 72-199 mu m) and at the 3.0 mm radius was 161.5 mu m (range 102-245 mu m). No correlation was found between (central) donor disk thickness and postoperative BCVA or change in SE. A nonstatistically significant trend was seen toward more improvement in BCVA with thinner donor disks. Conclusions: Optical coherence tomography Measurements of the manually dissected donor posterior disk showed significant variation in thickness, without a statistically significant effect on postoperative BCVA or improvement thereof. Central thickness varied significantly from the peripheral thickness within donor posterior disk.
引用
收藏
页码:298 / 303
页数:6
相关论文
共 25 条
[1]   Femtosecond-laser-assisted Descemet's stripping endothelial keratoplasty [J].
Cheng, Yanny Y. Y. ;
Pels, Elisabeth ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01) :152-155
[2]   Retinal assessment using optical coherence tomography [J].
Costa, Rogerio A. ;
Skaf, Mirian ;
Melo, Luiz A. S., Jr. ;
Calucci, Daniela ;
Cardillo, Jose A. ;
Castro, Jarbas C. ;
Huang, David ;
Wojtkowski, Maciej .
PROGRESS IN RETINAL AND EYE RESEARCH, 2006, 25 (03) :325-353
[3]   Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment [J].
Dada, Tanuj ;
Sihota, Ramanjit ;
Gadia, Ritu ;
Aggarwal, Anand ;
Mandal, Subrata ;
Gupta, Viney .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) :837-840
[4]   Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis? [J].
Konstantopoulos, Aristides ;
Hossain, Parwez ;
Anderson, David F. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (04) :551-557
[5]   Analysis of bleb morphology after trabeculectomy with Visante anterior segment optical coherence tomography [J].
Leung, Christopher Kai-shun ;
Yick, Doris Wai-fong ;
Kwong, Yolanda Yuen-ying ;
Li, Felix Chi-hong ;
Leung, Dexter Yu-lung ;
Mohamed, Shaheeda ;
Tham, Clement Chee-yung ;
Chung-chai, Chi ;
Lam, Dennis Shun-Chiu .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (03) :340-344
[6]   Agreement among 3 methods to measure corneal thickness: Ultrasound pachymetry, Orbscan II, and Visante anterior segment optical coherence tomography [J].
Li, Emmy Y. M. ;
Mohamed, Shaheeda ;
Leung, Christopher K. S. ;
Rao, Srinivas K. ;
Cheng, Arthur C. K. ;
Cheung, Carol Y. L. ;
Lam, Dennis S. C. .
OPHTHALMOLOGY, 2007, 114 (10) :1842-1847
[7]   Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography [J].
Li, Haitao ;
Leung, Christopher Kai Shun ;
Cheung, Carol Yim Lui ;
Wong, Lee ;
Pang, Chi Pui ;
Weinreb, Robert Neal ;
Lam, Dennis Shun Chiu .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) :1490-1492
[8]   A longitudinal study of LASIK flap and stromal thickness with high-speed optical coherence tomography [J].
Li, Yan ;
Netto, Marcelo V. ;
Shekhar, Raj ;
Krueger, Ronald R. ;
Huang, David .
OPHTHALMOLOGY, 2007, 114 (06) :1124-1132
[9]   Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism [J].
Maldonado, MJ ;
Ruiz-Oblitas, L ;
Munuera, JM ;
Aliseda, D ;
García-Layana, A ;
Moreno-Montañés, J .
OPHTHALMOLOGY, 2000, 107 (01) :81-87
[10]  
Melles GRJ, 2006, CORNEA, V25, P987, DOI 10.1097/01.ico.0000248385.16896.34