Radiation-induced light in optical fibers and plastic scintillators: Application to brachytherapy dosimetry

被引:42
作者
Arnfield, MR
Gaballa, HE
Zwicker, RD
Islam, Q
SchmidtUllrich, R
机构
[1] Department of Radiation Oncology, Medical College of Virginia, Richmond
关键词
ENERGY BEAM DOSIMETRY; CATHODOLUMINESCENCE; LUMINESCENCE; DETECTORS; CRYSTALS; SPECTRA;
D O I
10.1109/23.502302
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A small plastic scintillator bonded to an optical fiber has several characteristics that make it promising as a brachytherapy dosimeter, In these dosimeters, scintillation light represents signal, whereas Cerenkov and luminescence light from the optical fiber stem is noise that must be subtracted, The dosimeter accuracy can be improved by optically filtering part of the fiber stem light. Spectral measurements were performed to guide the choice of scintillator, fiber, and filter, Spectral signatures and total luminescence of three scintillators and five different silica optical fibers, excited by a 8 Ci Ir-192 source, were measured. The total radiation-induced light from the various optical fibers differed by up to a factor of 5.6, The percentage of fiber-produced light due to luminescence varied between 15 and 79%. A fiber with weak emission was used in the dosimeter with BC408S, a scintillator with minimum emission wavelength of 400 mm, A 400-nm cutoff UV filter gave a factor of two increase in signal-to-noise. The dosimeter response was linear for dose rates varying by at least three orders of magnitude, representing source-to-probe distances of 0.2-10 cm. Measurement errors of the dosimeter compare favorably with other brachytherapy dosimeters.
引用
收藏
页码:2077 / 2084
页数:8
相关论文
共 22 条
[1]  
Arnfield Mark P., 1995, International Journal of Radiation Oncology Biology Physics, V32, P296, DOI 10.1016/0360-3016(95)97972-4
[2]   OPTICAL PROPAGATION IN TISSUE WITH ANISOTROPIC SCATTERING [J].
ARNFIELD, MR ;
TULIP, J ;
MCPHEE, MS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (05) :372-381
[3]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[4]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[5]   CERENKOV LIGHT GENERATED IN OPTICAL FIBERS AND OTHER LIGHT PIPES IRRADIATED BY ELECTRON-BEAMS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (04) :925-935
[6]  
BEDDAR AS, 1988, MED PHYS, V15, P790
[7]  
BEDDAR AS, 1990, THESIS MED PHYSICS P
[8]   OPTICAL FILTERING AND SPECTRAL MEASUREMENTS OF RADIATION-INDUCED LIGHT IN PLASTIC SCINTILLATION DOSIMETRY [J].
DEBOER, SF ;
BEDDAR, AS ;
RAWLINSON, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (07) :945-958
[9]   TEMPERATURE-DEPENDENCE OF THE X-RAY-INDUCED LUMINESCENCE OF AL-NA-CONTAINING QUARTZ CRYSTALS [J].
HALPERIN, A ;
SUCOV, EW .
JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 1993, 54 (01) :43-50
[10]   A SCINTILLATION DOSE-RATE METER USING A TUNED LOW-FREQUENCY AMPLIFIER [J].
HERBERT, RJT .
BRITISH JOURNAL OF RADIOLOGY, 1956, 29 (342) :345-349