Inter- and Intraobserver Agreement in First Trimester Ultrasound Evaluation of Placental Biometry

被引:1
|
作者
Trilla, Cristina [1 ]
Medina, Maria C. [1 ]
Parra, Juan [1 ]
Llurba, Elisa [1 ]
Espinos, Juan Jose [1 ]
机构
[1] Hosp Santa Creu & Sant Pau, Dept Obstet & Gynecol, C St Quinti 89, ES-08025 Barcelona, Spain
关键词
3D ultrasound; Perinatal outcome; Interobserver agreement; Frist trimester pregnancy; Placenta; GESTATIONAL-AGE; 3-DIMENSIONAL ULTRASOUND; BIRTH-WEIGHT; VOLUME; PREDICTION; PREGNANCY; DOPPLER;
D O I
10.1159/000509707
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The aim of this study was to assess the clinical applicability of a new analytical software program by determining the inter- and intraobserver agreement for 2D placental biometry and three-dimensional (3D) placental volume (PV) in the first trimester. Methods: A prospective study of 25 singleton pregnancies between 11 and 14 weeks was conducted. 3D datasets were captured, and PV was estimated using the Phillips QLAB GI3DQ ultrasound quantification software. The basal plate (BP), chorionic plate (CP), placental thickness (PT), and the free uterine surface (FUS) area not occupied by placenta were considered for 2D biometry evaluation. Each variable was measured in 2 orthogonal planes with mean values used for the analysis. Intra- and interobserver agreement was evaluated. Results: Intraobserver agreement for both 2D and 3D measurements was high, particularly for the PV and PT (interclass correlation coefficient [ICC] 0.989 [95% confidence interval (CI) 0.97-0.99] and ICC 0.936 [95% CI 0.86-0.97], respectively). Interobserver agreement was good for the PV (ICC 0.963 [95% CI 0.91-0.98]), PT (ICC 0.822 [95% CI 0.63-0.91]), and CP (ICC 0.708 [95% CI 0.44-0.86]), but moderate for BP and FUS. Conclusions: PV, PT, and CP are reproducible measurements to evaluate first trimester placental biometry. Further research is needed to assess the clinical utility of these variables as predictors of poor obstetric outcomes.
引用
收藏
页码:834 / 840
页数:7
相关论文
共 43 条
  • [1] Comparison of inter- and intraobserver agreement and reliability between three different types of placental volume measurement technique (XI VOCAL™, VOCAL™ and multiplanar) and validity in the in-vitro setting
    Cheong, K. B.
    Leung, K. Y.
    Li, T. K. T.
    Chan, H. Y.
    Lee, Y. P.
    Tang, M. H. Y.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (02) : 210 - 217
  • [2] Inter- and Intraobserver Agreement of Canine and Feline Nervous System Tumors
    Belluco, Sara
    Avallone, Giancarlo
    Di Palma, Stefano
    Rasotto, Roberta
    Oevermann, Anna
    VETERINARY PATHOLOGY, 2019, 56 (03) : 342 - 349
  • [3] Intraobserver and interobserver variability in first-trimester transvaginal ultrasound cervical length
    Gascon, Andrea
    Goya, Maria
    Mendoza, Manel
    Gracia-Perez-Bonfils, Anna
    Higueras, Teresa
    Calero, Ines
    Aviles, Mayte
    Sanchez, Ma Angeles
    Llurba, Elisa
    Cabero, Luis
    Carreras, Elena
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2020, 33 (01) : 136 - 141
  • [4] Inter- and Intraobserver Agreement in the Assessment of Thyroid Nodule Ultrasound Features and Classification Systems: A Blinded Multicenter Study
    Persichetti, Agnese
    Di Stasio, Enrico
    Coccaro, Carmela
    Graziano, Filomena
    Bianchini, Antonio
    Di Donna, Vincenzo
    Corsello, Salvatore
    Valle, Dario
    Bizzarri, Giancarlo
    Frasoldati, Andrea
    Pontecorvi, Alfredo
    Papini, Enrico
    Guglielmi, Rinaldo
    THYROID, 2020, 30 (02) : 237 - 242
  • [5] Inter- and intraobserver agreement of seizure behavior scoring in the amygdala kindled rat
    Groot, L. J. J.
    Gosens, N.
    Vles, J. S. H.
    Hoogland, G.
    Aldenkamp, A. P.
    Rouhl, R. P. W.
    EPILEPSY & BEHAVIOR, 2015, 42 : 10 - 13
  • [6] Endoscopic classification of the papilla of Vater. Results of an inter- and intraobserver agreement study
    Haraldsson, E.
    Lundell, L.
    Swahn, F.
    Enochsson, L.
    Lohr, J. M.
    Arnelo, U.
    UNITED EUROPEAN GASTROENTEROLOGY JOURNAL, 2017, 5 (04) : 504 - 510
  • [7] Inter- and intraobserver variation in the histopathological evaluation of early oesophageal adenocarcinoma
    Grotenhuis, Brechtje A.
    van Heijl, Mark
    ten Kate, Fiebo J. W.
    Biermann, Katharina
    Offerhaus, G. Johan A.
    Wijnhoven, Bas P. L.
    Henegouwen, Mark I. van Berge
    Tilanus, Hugo W.
    van Lanschot, J. Jan B.
    JOURNAL OF CLINICAL PATHOLOGY, 2010, 63 (11) : 978 - 981
  • [8] Inter- and intraobserver agreement of antenatal cardiotocography assessments by maternity care professionals: A prospective study
    Neppelenbroek, Elise M.
    van Der Heijden, Olivier W. H.
    de Vet, Henrica C. W.
    de Groot, Amanda J. J.
    Daemers, Darie O. A.
    de Jonge, Ank
    Verhoeven, Corine J. M.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2024, 166 (03) : 1114 - 1120
  • [9] Reproducibility of First Trimester Three-dimensional Placental Measurements in the Evaluation of Early Placental Insufficiency
    Bujold, Emmanuel
    Effendi, Mona
    Girard, Mario
    Gouin, Katy
    Forest, Jean-Claude
    Couturier, Bernard
    Giguere, Yves
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2009, 31 (12) : 1144 - 1148
  • [10] Ultrasound Evaluation of the First Trimester
    Doubilet, Peter M.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2014, 52 (06) : 1191 - +