A simple, efficient and rapid HPLC-UV method for the detection of 5-HT in RIN-14B cell extract and cell culture medium

被引:9
|
作者
He, Qiangqiang [1 ,2 ,3 ]
Li, Maoru [4 ,5 ,6 ]
Wang, Xuechun [4 ]
Xia, Zhenjiang [1 ,2 ,3 ]
Du, Yuzhi [1 ,2 ]
Li, Yan [1 ,2 ,3 ]
Wei, Lixin [1 ,2 ]
Shang, Jing [1 ,2 ,4 ,5 ,6 ]
机构
[1] Chinese Acad Sci, Qinghai Key Lab Tibetan Med Pharmacol & Safety Ev, Northwest Inst Plateau Biol, Xining 810008, Qinghai, Peoples R China
[2] Chinese Acad Sci, Key Lab Tibetan Med Res, Northwest Inst Plateau Biol, Xining 810008, Qinghai, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] China Pharmaceut Univ, State Key Lab Nat Med, Nanjing 21198, Jiangsu, Peoples R China
[5] China Pharmaceut Univ, Jiangsu Key Lab TCM Evaluat & Translat Res, Nanjing 211198, Jiangsu, Peoples R China
[6] China Pharmaceut Univ, Sch Tradit Chinese Pharm, Nanjing 211198, Jiangsu, Peoples R China
关键词
HPLC-UV; Bioanalytical method validation; Cell culture medium; 5-Hydroxytryptamine; RIN-14B cells; SEROTONIN REGULATION; RAT; 5-HYDROXYTRYPTAMINE; TRANSPORTER; METABOLITES; ACTIVATION; TRYPTOPHAN; RELEASE; SYSTEM;
D O I
10.1186/s13065-019-0591-x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
5-Hydroxytryptamine (also known as 5-HT, serotonin) is one of the monoamine neurotransmitters which is distributed widely in plasma and brain of mammals and plays important roles in physiological manipulations. In the present method, we describe the development of a simple, efficient and rapid high performance liquid chromatographic method coupled with ultraviolet (HPLC-UV) detector for the qualitative and quantitative analysis of 5-HT in both cell extract and cell culture medium (RIN-14B). The experiments use repeated freeze-thaw cycles followed by centrifugation and direct injection of the supernatant into the chromatography. An analytical C18 column (Agilent Zorbax Extend, 4.6 x 250 mm, 5 mu m.) was taken for chromatographic separation; the mobile phase was 0.05 mol/L potassium dihydrogen phosphate (KH2PO4)/acetonitrile (90:10 v/v). Isocratic elution is established at the flow rate of 1.0 mL/min. The time required for this chromatographic run is 8 min. Over the concentration range of 0.1-10 mu g/mL, the calibration curve is linear in this method. Other unique characteristics and advantages include high accuracy (92.02-103.28%) and high precision (intra- and inter-day coefficients of variation <= 4.69%). This method is applicable for the investigation of drug/condition-response relationships in the function of synthesis and secretion of 5-HT in cultured RIN-14B cells in various in vitro studies.
引用
收藏
页数:9
相关论文
共 1 条
  • [1] A simple, efficient and rapid HPLC–UV method for the detection of 5-HT in RIN-14B cell extract and cell culture medium
    Qiangqiang He
    Maoru Li
    Xuechun Wang
    Zhenjiang Xia
    Yuzhi Du
    Yan Li
    Lixin Wei
    Jing Shang
    BMC Chemistry, 13