A heater-integrated transparent microchannel chip for continuous-flow PCR

被引:174
作者
Sun, K
Yamaguchi, A
Ishida, Y
Matsuo, S
Misawa, H
机构
[1] Univ Tokushima, Grad Sch Engn, Dept Ecosyst Engn, Tokushima 7708506, Japan
[2] Univ Tokushima, Satellite Venture Business Lab Photon Nano Mat, Tokushima 7708506, Japan
[3] Shikoku Res Inst Inc, Takamatsu, Kagawa 7610192, Japan
关键词
microchannel; PCR; ITO; PS-Na; Escherichia coli HB101;
D O I
10.1016/S0925-4005(02)00016-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microchannel chip for continuous-flow polymerase chain reaction (PCR) was developed using transparent materials. The microchannel was fabricated on a quartz glass substrate using standard photolithography and wet-etching techniques and was sealed by another quartz glass substrate. Two indium-tin-oxide (ITO) films were deposited on the etched substrate as a thermal source. To confirm the temperature distribution in the microchannel, we measured the fluorescence spectra of an aqueous solution of 1-pyrenesulfonic acid sodium salt (PS-Na), which is a temperature-indicator dye, in the microchannel under a continuous solution flow. The results confirm that the temperature distribution on the microchannel's ITO films was almost uniform (within +/-2 degreesC) under two flow rates (56 and 152 nl/min). The slightness of this deviation indicates that the ITO films integrated into the microchannel chip can be very useful as a thermal source for PCR. An amplification of a 450 bp segment of Escherichia coli HB101 was successfully per-formed by two-stage (94 and 67 degreesC) thermal cycling on the chip device. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:283 / 289
页数:7
相关论文
共 19 条
  • [1] KINETIC PCR ANALYSIS - REAL-TIME MONITORING OF DNA AMPLIFICATION REACTIONS
    HIGUCHI, R
    FOCKLER, C
    DOLLINGER, G
    WATSON, R
    [J]. BIO-TECHNOLOGY, 1993, 11 (09): : 1026 - 1030
  • [2] Real-time microchip PCR for detecting single-base differences in viral and human DNA
    Ibrahim, MS
    Lofts, RS
    Jahrling, PB
    Henchal, EA
    Weedn, VW
    Northrup, MA
    Belgrader, P
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (09) : 2013 - 2017
  • [3] Reversible phase transitions in polymer gels induced by radiation forces
    Juodkazis, S
    Mukai, N
    Wakaki, R
    Yamaguchi, A
    Matsuo, S
    Misawa, H
    [J]. NATURE, 2000, 408 (6809) : 178 - 181
  • [4] Integrated system for rapid PCR-based DNA analysis in microfluidic devices
    Khandurina, J
    McKnight, TE
    Jacobson, SC
    Waters, LC
    Foote, RS
    Ramsey, JM
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (13) : 2995 - 3000
  • [5] Chemical amplification: Continuous-flow PCR on a chip
    Kopp, MU
    de Mello, AJ
    Manz, A
    [J]. SCIENCE, 1998, 280 (5366) : 1046 - 1048
  • [6] Monolithic integrated microfluidic DNA amplification and capillary electrophoresis analysis system
    Lagally, ET
    Simpson, PC
    Mathies, RA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (03): : 138 - 146
  • [7] Morrison TB, 1998, BIOTECHNIQUES, V24, P954
  • [8] Studies on SiO2-SiO2 bonding with hydrofluoric acid.: Room temperature and low stress bonding technique for MEMS
    Nakanishi, H
    Nishimoto, T
    Nakamura, R
    Yotsumoto, A
    Yoshida, T
    Shoji, S
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2000, 79 (03) : 237 - 244
  • [9] Condition optimization, reliability evaluation of SiO2-SiO2HF bonding and its application for UV detection micro flow cell
    Nakanishi, H
    Nishimoto, T
    Kanai, M
    Saitoh, T
    Nakamura, R
    Yoshida, T
    Shoji, S
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2000, 83 (1-3) : 136 - 141
  • [10] A miniature analytical instrument for nucleic acids based on micromachined silicon reaction chambers
    Northrup, MA
    Benett, B
    Hadley, D
    Landre, P
    Lehew, S
    Richards, J
    Stratton, P
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (05) : 918 - 922