Clinical Value of Tc99m-MIBI SPECT/CT Versus 4D-CT or US in Management of Patients With Hyperparathyroidism

被引:37
作者
Kedarisetty, Suraj [1 ]
Fundakowski, Christopher [1 ]
Ramakrishnan, Karthika [2 ]
Dadparvar, Simin [2 ]
机构
[1] Temple Univ, Sch Med, Lewis Katz Sch Med, Dept Otolaryngol Head & Neck Surg, Philadelphia, PA 19122 USA
[2] Temple Univ, Sch Med, Lewis Katz Sch Med, Dept Radiol,Div Nucl Med & Mol Imaging, Philadelphia, PA 19122 USA
关键词
hyperparathyroidism; parathyroid adenoma; Tc99m-MIBI; SPECT; CT; 4D-CT; ultrasound; MINIMALLY INVASIVE PARATHYROIDECTOMY; HORMONE LEVEL; 4D MRI; LOCALIZATION; SESTAMIBI; ADENOMAS; SCINTIGRAPHY; ULTRASONOGRAPHY; HYPERCALCEMIA; SENSITIVITY;
D O I
10.1177/0145561319828668
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Localization of parathyroid adenomas for treatment of primary hyperparathyroidism can be challenging. This retrospective study compared single-photon emission computed tomography/computed tomography (SPECT/CT), 4D-CT, and US studies in detection of adenomas prior to surgery. A retrospective chart review was performed on all consecutive patients with parathyroid adenoma presenting to an urban tertiary care medical center. A total of 58 patients (45 female, 13 male) underwent surgery for parathyroid adenoma. Patients aged 28 to 80 years (mean: 58.8) with parathyroid hormone levels ranging from 42 to 424 pg/mL (mean: 168). All patients underwent preoperative SPECT/CT with 20 mCi technetium-99m MIBI (Tc-99m-MIBI). Fifty-three patients had additional US imaging and 14 patients had 4D-CT scans. Additionally, 34 patients had injection of 20 mCi Tc-99m-MIBI on the day of surgery. Pathological correlation was performed. Comparing SPECT/CT versus 4D-CT resulted in sensitivity (77% vs 80%), specificity (71% vs 75%), and accuracy (77% vs 79%). Ultrasound was less sensitive with similar specificity (44%, 86%, respectively). Combination of SPECT/CT and 4D-CT increased sensitivity to 88%, specificity to 100%, and accuracy to 89%. Combining SPECT/CT with US resulted in sensitivity of 85%, specificity of 83%, and accuracy of 85%. Intraoperative localization substantially improved in patients who received preoperative injections. The SPECT/CT remains the best imaging modality for preoperative localization of parathyroid adenomas with high sensitivity. Combining SPECT/CT with US resulted in increased sensitivity and accuracy. For suspicion of ectopic cases or suspicion of unidentifiable adenoma with negative scintigraphy, addition of 4D-CT is recommended. Intraoperative localization and adjunctive imaging may improve surgical management of patients with hyperparathyroidism.
引用
收藏
页码:149 / 157
页数:9
相关论文
共 39 条
  • [11] Giusti F, 1993, MULTIPLE ENDOCRINE N, V1
  • [12] Ultrasonography for preoperative localization of enlarged parathyroid glands in primary hyperparathyroidism:: comparison with 99mtechnetium sestamibi scintigraphy
    Haber, RS
    Kim, CK
    Inabnet, WB
    [J]. CLINICAL ENDOCRINOLOGY, 2002, 57 (02) : 241 - 249
  • [13] 4D-CT is Superior to Ultrasound and Sestamibi for Localizing Recurrent Parathyroid Disease
    Hamidi, Moska
    Sullivan, Michael
    Hunter, George
    Hamberg, Leena
    Cho, Nancy L.
    Gawande, Atul A.
    Doherty, Gerard M.
    Moore, Francis D., Jr.
    Nehs, Matthew A.
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2018, 25 (05) : 1403 - 1409
  • [14] Parathyroid 4D-CT: Multi-institutional International Survey of Use and Trends
    Hoang, Jenny K.
    Williams, Katherine
    Gaillard, Frank
    Dixon, Andrew
    Sosa, Julie A.
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2016, 155 (06) : 956 - 960
  • [15] Mediastinal parathyroid adenomas and their surgical implications
    Hu, Jesse
    Ngiam, K. Y.
    Parameswaran, R.
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2015, 97 (04) : 259 - 261
  • [16] Secondary and Tertiary Hyperparathyroidism
    Jamal, Sophie A.
    Miller, Paul D.
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2013, 16 (01) : 64 - 68
  • [17] Focused Versus Bilateral Parathyroid Exploration for Primary Hyperparathyroidism: A Systematic Review and Meta-analysis
    Jinih, Marcel
    O'Connell, Emer
    O'Leary, Donal P.
    Liew, Aaron
    Redmond, Henry P.
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2017, 24 (07) : 1924 - 1934
  • [18] Parathyroid nuclear scan. A focused review on the technical and biological factors affecting its outcome
    Kannan, Subramanian
    Milas, Mira
    Neumann, Donald
    Parikh, Rikesh T.
    Siperstein, Alan
    Licata, Angelo
    [J]. CLINICAL CASES IN MINERAL AND BONE METABOLISM, 2014, 11 (01) : 25 - 30
  • [19] Use of PET tracers for parathyroid localization: a systematic review and meta-analysis
    Kluijfhout, Wouter P.
    Pasternak, Jesse D.
    Drake, Frederick Thurston
    Beninato, Toni
    Gosnell, Jessica E.
    Shen, Wen T.
    Duh, Quan-Yang
    Allen, Isabel E.
    Vriens, Menno R.
    de Keizer, Bart
    Pampaloni, Miguel H.
    Suh, Insoo
    [J]. LANGENBECKS ARCHIVES OF SURGERY, 2016, 401 (07) : 925 - 935
  • [20] Enabling minimal invasive parathyroidectomy for patients with primary hyperparathyroidism using Tc-99m-sestamibi SPECT-CT, ultrasound and first results of 18F-fluorocholine PET-CT
    Kluijfhout, Wouter P.
    Vorselaars, Wessel M. C. M.
    Vriens, Menno R.
    Rinkes, Inne H. M. Borel
    Valk, Gerlof D.
    de Keizer, Bart
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) : 1745 - 1751