Positioning error and expanding margins of planning target volume with kilovoltage cone beam computed tomography for prostate cancer radiotherapy

被引:4
作者
Wang, Gang [1 ]
Wang, Wen-Ling [1 ]
Liu, Yi-Qun [1 ]
Dong, Hong-Min [1 ]
Hu, Yin-Xiang [1 ]
机构
[1] Guizhou Med Univ, Dept Abdominal Oncol, Affiliated Hosp, Guizhou Canc Hosp, 1 West Beijing Rd, Guiyang 550004, Guizhou, Peoples R China
来源
ONCOTARGETS AND THERAPY | 2018年 / 11卷
关键词
prostate cancer; image-guided radiotherapy; kilovoltage cone beam CT; positioning error; planning target volume; INTENSITY-MODULATED RADIOTHERAPY; PTV MARGINS; ROTATION; MOTION;
D O I
10.2147/OTT.S152915
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective: In this study, prostate cancer patients were treated with image-guided radiotherapy (IGRT). The translational positioning errors were discussed to provide the basis for determining margins of the planning target volume (PTV). Methods: Thirty prostate cancer patients were treated with radical radiotherapy using the IGRT system. Patients were placed in the supine position and underwent kilovoltage cone beam computed tomography (KVCBCT) scans before radiotherapy. A total of 447 images were acquired. The translational positioning errors were obtained in three linear directions which were X (left-to-right), Y (superior-to-inferior) and Z (anterior-to-posterior) axes (denoted as Lx, Ly and Lz) through the contrast between images adjusted with gray and manual registrations and the planning CT images. Rotational errors were denoted as Rx, Ry and Rz. Results: Uncorrected translational errors Lx, Ly and Lz in the 251 positioning images were all higher than those after correction, and the differences were all statistically significant (P=0.000, 0.037 and 0.004, respectively). For rotational errors Rx, Ry and Rz, only Rx had a significant difference before and after correction (P=0.044). Before correction, PTV margins in the X, Y and Z directions were 0.61, 0.78 and 0.41 cm, respectively; after correction, these were 0.17, 0.12 and 0.17 cm, respectively. Conclusion: KVCBCT can be applied to measure positioning errors in prostate cancer radiotherapy and correct these errors in real time through the 6 degrees robotic patient positioning system, in order to improve patient positioning accuracy. The application of IGRT with KVCBCT may reduce PTV margins. Keywords: prostate
引用
收藏
页码:1981 / 1988
页数:8
相关论文
共 23 条
  • [1] Analysis of interfraction prostate motion using megavoltage cone beam computed tomography
    Bylund, Kevin C.
    Bayouth, John E.
    Smith, Mark C.
    Hass, A. Curtis
    Bhatia, Sudershan K.
    Buatti, John M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (03): : 949 - 956
  • [2] Displacements of fiducial markers in patients with prostate cancer treated with image guided radiotherapy: A single-institution descriptive study
    Cendales, Ricardo
    Torres, Felipe
    Arbelaez, Juan
    Gaitan, Armando
    Vasquez, Jaider
    Bobadilla, Ivan
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (01) : 38 - 42
  • [3] Is There an Advantage in Designing Adapted, Patient-Specific PTV Margins in Intensity Modulated Proton Beam Therapy for Prostate Cancer?
    Gora, Joanna
    Stock, Markus
    Luetgendorf-Caucig, Carola
    Georg, Dietmar
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (03): : 881 - 888
  • [4] Interfraction rotation of the prostate as evaluated by kilovoltage X-ray fiducial marker imaging in intensity-modulated radiotherapy of localized prostate cancer
    Graf, Reinhold
    Boehmer, Dirk
    Budach, Volker
    Wust, Peter
    [J]. MEDICAL DOSIMETRY, 2012, 37 (04) : 396 - 400
  • [5] Hoskin P., 2012, EXTERNAL BEAM THERAP
  • [6] Assessment of interfractional prostate motion in patients immobilized in the prone position using a thermoplastic shell
    Ikeda, Itaru
    Mizowaki, Takashi
    Sawada, Yohei
    Nakata, Manabu
    Norihisa, Yoshiki
    Ogura, Masakazu
    Hiraoka, Masahiro
    [J]. JOURNAL OF RADIATION RESEARCH, 2014, 55 (01) : 168 - 174
  • [7] Kanakavelu N, 2016, J BUON, V21, P505
  • [8] Daily online localization using implanted fiducial markers and its impact on planning target volume for carcinoma prostate
    Khosa, Robin
    Nangia, Sapna
    Chufal, Kundan S.
    Ghosh, D.
    Kaul, Rakesh
    Sharma, Lalit
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2010, 6 (02) : 172 - 178
  • [9] Kliton Jorgo, 2012, Magy Onkol, V56, P193
  • [10] Adaptive radiotherapy for prostate cancer using kilovoltage cone-beam computed tomography: First clinical results
    Nijkamp, Jasper
    Pos, Floris J.
    Nuver, Tonnis T.
    De Jong, Rianne
    Remeijer, Peter
    Sonke, Jan-Jakob
    Lebesque, Joos V.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01): : 75 - 82