Sensitivity of Resonance Frequency Analysis for Detecting Early Implant Failure: A Case-Control Study

被引:21
作者
Monje, Alberto [1 ]
Ortega-Oller, Inmaculada [2 ]
Galindo-Moreno, Pablo [2 ]
Catena, Andres [3 ]
Monje, Florencio [4 ]
O'Valle, Francisco [5 ,6 ]
Suarez, Fernando [1 ]
Wang, Hom-Lay [1 ]
机构
[1] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[2] Univ Granada, Sch Dent, Oral Surg & Implant Dent Dept, Granada, Spain
[3] Univ Granada, Sch Psychol, Dept Expt Psychol, Granada, Spain
[4] Ctr Implantol Oral & Maxillofacial Surg CICOM, Badajoz, Spain
[5] Univ Granada, Sch Med, Dept Pathol, Granada, Spain
[6] Univ Granada, IBIMER, Granada, Spain
关键词
early failure; implant failure; implant stability; ISQ; primary stability; resonance frequency analysis; PRIMARY STABILITY; BONE-DENSITY; EDENTULOUS MAXILLA; LOADED IMPLANTS; DENTAL IMPLANTS; IMMEDIATE; OSSEOINTEGRATION; DIAMETER; CADAVER; IMPACT;
D O I
10.11607/jomi.3357
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to test the sensitivity of the resonance frequency analysis for detecting early implant failure. Materials and Methods: In all, 3,786 implants placed from June 2007 to January 2013 were retrospectively evaluated. A total of 20 implants (in 20 patients) placed in pristine bone were found to have failed before loading. The implant stability quotient (ISQ) values were extracted from these 20 implants at baseline (immediate) and 4 months after placement (delayed). Simple linear regression, logistic regression, and two-way contingency tables were used to test for the relationships between ISQ values and early implant failure. Results: Immediate ISQ values were significantly related to failure (odds ratio [OR] = 4.27). Furthermore, the results of the second regression showed a significant relationship between ISQ at delayed measurement and implant failure (OR = 9.20). For immediate ISQ, it seems that the 73.7% correct classifications were obtained at the cost of an incorrect classification of 55% of the implant failures. However, for the delayed ISQ, 86.2% correct classifications were obtained at the cost of assuming that all implants will survive. Conclusion: The present study showed that ISQ values are not reliable in predicting early implant failure. In addition, the real cutoff ISQ value to differentiate between success and early implant failure remains to be determined.
引用
收藏
页码:456 / 461
页数:6
相关论文
共 33 条
  • [1] Al-Nawas B, 2006, INT J ORAL MAX IMPL, V21, P726
  • [2] Atieh MA, 2012, INT J PROSTHODONT, V25, P326
  • [3] Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
  • [4] Balleri Piero, 2002, Clin Implant Dent Relat Res, V4, P128, DOI 10.1111/j.1708-8208.2002.tb00162.x
  • [5] Implant stability measurement of delayed and immediately loaded implants during healing. A clinical resonance-frequency analysis study with sandblasted-and-etched ITI implants
    Bischof, M
    Nedir, R
    Szmukler-Moncler, S
    Bernard, JP
    Samson, J
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (05) : 529 - 539
  • [6] Influence on early osseointegration of dental implants installed with two different drilling protocols: a histomorphometric study in rabbit
    Blanco, Juan
    Alvarez, Elena
    Munoz, Fernando
    Linares, Antonio
    Cantalapiedra, Antonio
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (01) : 92 - 99
  • [7] Brunski J B, 1988, J Dent Educ, V52, P775
  • [8] Influence of the orientation of the Osstell® transducer during measurement of dental implant stability using resonance frequency analysis: A numerical approach
    Capek, Lukas
    Simunek, Antonin
    Slezak, Radovan
    Dzan, Ladislav
    [J]. MEDICAL ENGINEERING & PHYSICS, 2009, 31 (07) : 764 - 769
  • [9] Cehreli MC, 2009, INT J ORAL MAX IMPL, V24, P1015
  • [10] Implant Primary Stability Determined by Resonance Frequency Analysis in Surgically Created Defects: A Pilot Cadaver Study
    Chan, Hsun-Liang
    El-Kholy, Karim
    Fu, Jia-Hui
    Galindo-Moreno, Pablo
    Wang, Hom-Lay
    [J]. IMPLANT DENTISTRY, 2010, 19 (06) : 509 - 519