Scatter modelling and compensation in emission tomography

被引:152
作者
Zaidi, H [1 ]
Koral, KF
机构
[1] Univ Hosp Geneva, Div Nucl Med, CH-1211 Geneva, Switzerland
[2] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
emission tomography; scatter modelling; scatter correction; reconstruction; quantification;
D O I
10.1007/s00259-004-1495-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In nuclear medicine, clinical assessment and diagnosis are generally based on qualitative assessment of the distribution pattern of radiotracers used. In addition, emission tomography (SPECT and PET) imaging methods offer the possibility of quantitative assessment of tracer concentration in vivo to quantify relevant parameters in clinical and research settings, provided accurate correction for the physical degrading factors (e.g. attenuation, scatter, partial volume effects) hampering their quantitative accuracy are applied. This review addresses the problem of Compton scattering as the dominant photon interaction phenomenon in emission tomography and discusses its impact on both the quality of reconstructed clinical images and the accuracy of quantitative analysis. After a general introduction, there is a section in which scatter modelling in uniform and non-uniform media is described in detail. This is followed by an overview of scatter compensation techniques and evaluation strategies used for the assessment of these correction methods. In the process, emphasis is placed on the clinical impact of image degradation due to Compton scattering. This, in turn, stresses the need for implementation of more accurate algorithms in software supplied by scanner manufacturers, although the choice of a general-purpose algorithm or algorithms may be difficult.
引用
收藏
页码:761 / 782
页数:22
相关论文
共 108 条
[1]   Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations [J].
Adam, LE ;
Karp, JS ;
Brix, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12) :2879-2895
[2]  
[Anonymous], QUANTITATIVE ANAL NU
[3]   A CONVOLUTION-SUBTRACTION SCATTER CORRECTION METHOD FOR 3D PET [J].
BAILEY, DL ;
MEIKLE, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :411-424
[4]  
Bailey DL, 1998, DEV NUC MED, V32, P55
[5]   OBJECT SHAPE DEPENDENT SCATTER SIMULATIONS FOR PET [J].
BARNEY, JS ;
ROGERS, JG ;
HARROP, R ;
HOVERATH, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :719-725
[6]   OBJECTIVE ASSESSMENT OF IMAGE QUALITY .2. FISHER INFORMATION, FOURIER CROSSTALK, AND FIGURES OF MERIT FOR TASK-PERFORMANCE [J].
BARRETT, HH ;
DENNY, JL ;
WAGNER, RF ;
MYERS, KJ .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (05) :834-852
[7]   Scatter compensation methods in 3D iterative SPECT reconstruction: A simulation study [J].
Beekman, FJ ;
Kamphuis, C ;
Frey, EC .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (08) :1619-1632
[8]   SPECT scatter modelling in non-uniform attenuating objects [J].
Beekman, FJ ;
denHarder, JM ;
Viergever, MA ;
vanRijk, PP .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06) :1133-1142
[9]   Efficient SPECT scatter calculation in non-uniform media using correlated Monte Carlo simulation [J].
Beekman, FJ ;
de Jong, HWAM ;
Slijpen, ETP .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08) :N183-N192
[10]   Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation [J].
Beekman, FJ ;
de Jong, HWAM ;
van Geloven, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) :867-877