Biomechanical Study of Femoral Bone after Proximal Bone Tumor Removal

被引:0
作者
Aroonjarattham, Panya [1 ]
Kijthaworn, Peeranat [1 ]
Jamda, Promchai [1 ]
Supamongkol, Tanakorn [1 ]
Suwanboriboon, Samart [2 ]
Aroonjarattham, Kitti [2 ]
Somtua, Chompunut [1 ]
机构
[1] Mahidol Univ, Fac Engn, Dept Mech Engn, Nakhon Pathom 73170, Thailand
[2] Burapha Univ, Fac Med, Dept Orthopaed, Chon Buri 20131, Thailand
来源
9TH THAI SOCIETY OF MECHANICAL ENGINEERS, INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (TSME-ICOME 2018) | 2019年 / 501卷
关键词
LAW;
D O I
10.1088/1757-899X/501/1/012036
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Proximal femur is connected between pelvis and the lower extremity to carry the body weight that transfer from the upper body to the lower part. The patients, had the proximal femur bone tumor had a problem in daily activities. The most treatment for bone tumor has two methods as radiation and surgery method. The surgeon removed the bone tumor, replaced with the other proximal femur and fixed by dynamic hip screw and four screws fixation. This study aim to analyse the postoperative results after surgery with finite element analysis, were divided into six cases as the same size proximal femur, 15% and 30% small proximal femur, 15% and 30% large proximal femur and the same size proximal femur constructed by polymethyl methacrylate (PMMA). The result were shown the maximum strain on the small size higher than another cases under walking and stair-climbing load and the same size proximal femur constructed by PMMA had the lowest maximum equivalent of total strain. The surgeon should be replacing the proximal femur with the same or the larger size of femur or the same size constructed by PMMA for a good clinical result.
引用
收藏
页数:7
相关论文
共 8 条
  • [1] Finite element analysis of human knee joint in varus-valgus
    Bendjaballah, MZ
    ShiraziAdl, A
    Zukor, DJ
    [J]. CLINICAL BIOMECHANICS, 1997, 12 (03) : 139 - 148
  • [2] FROST HM, 1994, ANGLE ORTHOD, V64, P175
  • [3] Frost HM, 2004, ANGLE ORTHOD, V74, P3
  • [4] Kirmani O, 2013, GLOBAL J SURG, V1, P22
  • [5] Morphological study of the proximal femur: a new method of geometrical assessment using 3-dimensional reverse engineering
    Mahaisavariya, B
    Sitthiseripratip, K
    Tongdee, T
    Bohez, ELJ
    Vander Sloten, J
    Oris, P
    [J]. MEDICAL ENGINEERING & PHYSICS, 2002, 24 (09) : 617 - 622
  • [6] A computational evaluation of the effect of intramedullary nail material properties on the stabilization of simulated femoral shaft fractures
    Perez, Angel
    Mahar, Andrew
    Negus, Charles
    Newton, Peter
    Impelluso, Tom
    [J]. MEDICAL ENGINEERING & PHYSICS, 2008, 30 (06) : 755 - 760
  • [7] Silva Paulo, 2016, Rev. bras. ortop., V51, P739, DOI 10.1016/j.rboe.2016.09.006
  • [8] Computational modeling of ligament mechanics
    Weiss, JA
    Gardiner, JC
    [J]. CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 2001, 29 (03) : 303 - 371