Investigation on the Corrosion Behavior of Lean Duplex Stainless Steel 2404 after Aging within the 650-850 °C Temperature Range

被引:6
作者
Zanotto, Federica [1 ]
Grassi, Vincenzo [1 ]
Balbo, Andrea [1 ]
Zucchi, Fabrizio [1 ]
Monticelli, Cecilia [1 ]
机构
[1] Univ Ferrara, Aldo Dacco Corros & Met Study Ctr, Via G Saragat 4A, I-44122 Ferrara, Italy
关键词
duplex stainless steel; pitting corrosion; intergranular corrosion; CPT; DL-EPR; FIB-SEM technique; INTERGRANULAR CORROSION; PITTING CORROSION; ANNEALING TEMPERATURE; LDX 2101(R); SUSCEPTIBILITY; RESISTANCE; CHLORIDE; CRACKING; PRECIPITATION; EVOLUTION;
D O I
10.3390/met9050529
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper reports the effects of thermal aging between 650 and 850 degrees C on the localized corrosion behavior of lean duplex stainless steel (LDSS 2404). Critical pitting temperature (CPT) and double loop electrochemical potentiokinetic reactivation (DL-EPR) tests were performed. The localization of pitting attack and intergranular corrosion (IGC) attack after DL-EPR was investigated by optical (OM) and scanning electron microscopy (SEM) and by focused ion beam (FIB) coupled to SEM. Thermal aging caused the precipitation of mainly chromium nitrides at grain boundaries. Aging at 650 degrees C or short aging times (5 min) at 750 degrees C caused nitride precipitation mainly at alpha/alpha grain boundaries as a result of fast diffusion of chromium in this phase. Aging at 850 degrees C or aging times from 10 to 60 min at 750 degrees C also allowed the precipitation at the alpha/gamma interface. Nitrides at gamma/gamma grain boundaries were observed rarely and only after long aging times (60 min) at 850 degrees C. Electrochemical tests showed that in as-received samples, pitting attack only affected the alpha phase. Conversely, in aged samples, pitting and IGC attack were detected close to nitrides in correspondence of alpha/alpha and alpha/gamma grain boundaries depending on aging temperatures and times.
引用
收藏
页数:15
相关论文
共 36 条
  • [1] AlvarezArmas I, 2009, DUPLEX STAINLESS STEELS, P1
  • [2] Double loop electrochemical potentiokinetic reactivation test optimization in checking of duplex stainless steel intergranular corrosion susceptibility
    Amadou, T
    Braham, C
    Sidhom, H
    [J]. METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2004, 35A (11): : 3499 - 3513
  • [3] ASTM International, 2015, A262 ASTM INT
  • [4] σ-Phase in Lean Duplex Stainless Steel Sheets
    Breda, Marco
    Pellizzari, Massimo
    Frigo, Marco
    [J]. ACTA METALLURGICA SINICA-ENGLISH LETTERS, 2015, 28 (03) : 331 - 337
  • [5] Canderyd C., 2012, P CORROSION 2012 SAL
  • [6] Charles J, 2010, P 8 DUPL STAINL STEE
  • [7] Application of the modified electrochemical potentiodynamic reactivation method to detect susceptibility to intergranular corrosion of a newly developed lean duplex stainless steel LDX2101
    Deng, Bo
    Jiang, Yiming
    Xu, Juliang
    Sun, Tao
    Gao, Juan
    Zhang, Lihua
    Zhang, Wei
    Li, Jin
    [J]. CORROSION SCIENCE, 2010, 52 (03) : 969 - 977
  • [8] Evaluation of intergranular corrosion susceptibility of UNS S31803 duplex stainless steel with an optimized double loop electrochemical potentiokinetic reactivation method
    Gong, Jia
    Jiang, Y. M.
    Deng, B.
    Xu, J. L.
    Hu, J. P.
    Li, Jin
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (18) : 5077 - 5083
  • [9] Effect of Solution Annealing Temperature on Pitting Behavior of Duplex Stainless Steel 2204 in Chloride Solutions
    He, Liang
    Gu, Yan-jun
    Wu, Xia-yu
    Jiang, Yi-ming
    Li, Jin
    [J]. JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL, 2016, 23 (04) : 357 - 363
  • [10] Evaluation of aged duplex stainless steel UNS S32750 susceptibility to intergranular corrosion by optimized double loop electrochemical potentiokinetic reactivation method
    Hong, Jufeng
    Han, Dong
    Tan, Hua
    Li, Jin
    Jiang, Yiming
    [J]. CORROSION SCIENCE, 2013, 68 : 249 - 255