Comparision of photo pulse plethysmography module with Mobil-O-graph for measurement of pulse wave velocity

被引:5
|
作者
Kumar, A. V. Siva [1 ]
MaheshKumar, K. [2 ]
Maruthy, K. N. [3 ]
Padmavathi, R. [4 ]
机构
[1] Sri Ramachandra Med Coll & Res Inst, Dept Physiol, Chennai 600116, Tamil Nadu, India
[2] Govt Yoga & Naturopathy Coll & Hosp, Dept Physiol & Biochem, Chennai 600104, Tamil Nadu, India
[3] Narayana Med Coll, Dept Physiol, Nellore 524003, Andhra Pradesh, India
[4] SRIHER, Sri Ramachandra Med Coll & Reserach Inst, Dept Physiol, Chennai 600116, Tamil Nadu, India
来源
CLINICAL EPIDEMIOLOGY AND GLOBAL HEALTH | 2021年 / 9卷
关键词
Pulse wave velocity; Photo pulse plethysmography; Pulse transit time; CENTRAL BLOOD-PRESSURE; ARTERIAL STIFFNESS; VALIDATION; SPHYGMOCOR; ARTERIOGRAPH; COMPLIOR; DEVICE; ECG;
D O I
10.1016/j.cegh.2020.09.001
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Introduction:Pulse wave velocity (PWV) is an indicator of arterial stiffness and one of the prognostic tools in clinical practice. We compared the finger photo pulse plethysmography (PPG) module with the Mobil-O-Graph for assessment of PWV. Material and methods: 80 healthy subjects and patients have participated in this study, among them, 42 were males, and 38 were females. Recording for the subjects was executed between 9, and 11 a.m., after a light breakfast. Lead - II ECG along with PPG were recorded in dual channel AD converter and Mobil-O-Graph simultaneously. The analogue signals of both the devices of the AD converter were digitized by using the sound card of the computer for the measurement of Pulse Transit Time [PTT]. Results: The mean age of the participants was 41.5 +/- 5.48 and BMI-26.42 +/- 5.80. PWV values measured by the devices were similar (P > 0.05). There is a significant positive correlation of PWV between PPG and Mobil O graph, r-0.92 (p = 0.001). Bland-Altman analysis indicated that a mean difference for PWV is .0.3 m/s, which is limits of agreement (1.4-2.4) between PPG and Mobil-O-Graph. Intra-class correlation (ICC) for PWV was 0.89, and the coefficient of variation (CV) was 9.2%. Conclusion: Based on the findings of the present study, we suggest that the measurement of PWV obtained from the PPG is probably a reliable one. It offers the advantages of lower cost and greater practicality about application and usage.
引用
收藏
页码:216 / 220
页数:5
相关论文
共 50 条
  • [41] Feasibility of a method for measurement of retinal pulse-propagated wave velocity in humans
    Tang, Zhengxin
    Felder, Anthony E.
    Shahidi, Mahnaz
    MICROVASCULAR RESEARCH, 2025, 159
  • [42] A Comparative Review of Blood Pressure Measurement Methods Using Pulse Wave Velocity
    Mazaheri, Samaneh
    Zahedi, Edmond
    2014 IEEE INTERNATIONAL CONFERENCE ON SMART INSTRUMENTATION, MEASUREMENT AND APPLICATIONS (ICSIMA), 2014,
  • [43] Measurement of pulse wave velocity using magnetic resonance imaging
    Gang, G
    Mark, P
    Cockshott, P
    Foster, J
    Martin, T
    Blyth, K
    Steedman, T
    Elliott, A
    Dargie, H
    Groenning, B
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3684 - 3687
  • [44] Simplified pulse wave velocity measurement in children: Is the pOpmetre valid?
    Bichali, Said
    Bruel, Alexandra
    Boivin, Marion
    Roussey, Gwenaelle
    Romefort, Benedicte
    Roze, Jean-Christophe
    Allain-Launay, Emma
    PLOS ONE, 2020, 15 (03):
  • [45] COMPARISON OF DIFFERENT PULSE WAVEFORMS FOR LOCAL PULSE WAVE VELOCITY MEASUREMENT IN HEALTHYAND HYPERTENSIVE COMMON CAROTID ARTERIES IN VIVO
    Huang, Chengwu
    Su, Yuan
    Zhang, Hong
    Qian, Lin-Xue
    Luo, Jianwen
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (05): : 1111 - 1123
  • [46] Improving the accuracy and robustness of carotid-femoral pulse wave velocity measurement using a simplified tube-load model
    Xu, Lisheng
    Zhou, Shuran
    Wang, Lu
    Yao, Yang
    Hao, Liling
    Qi, Lin
    Yao, Yudong
    Han, Hongguang
    Mukkamala, Ramakrishna
    Greenwald, Stephen E.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [47] Acute effects of ultrafiltration on aortic mechanical properties determined by measurement of pulse wave velocity and pulse propagation time in hemodialysis patients
    Yildiz, Banu Sahin
    Sahin, Alparslan
    Aladag, Nazire Baskurt
    Arslan, Gulgun
    Kaptanogullari, Hakan
    Akin, Ibrahim
    Yildiz, Mustafa
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2015, 15 (04): : 313 - 317
  • [48] Pulse Wave Velocity Measurement in the Carotid Artery Using an LED-LED Array Pulse Oximeter
    Campbell, Jake D.
    Holder-Pearson, Lui
    Pretty, Christopher G.
    Bones, Phil
    Chase, J. Geoffrey
    IFAC PAPERSONLINE, 2020, 53 (02): : 16031 - 16036
  • [49] THE IMPORTANCE OF PULSE WAVE VELOCITY AND CENTRAL BLOOD PRESSURE MEASUREMENT IN PATIENTS WITH RESISTANT HYPERTENSION
    Vamsi, Varahabhatla Sai Krishna Raghu
    Prkacin, Ingrid
    Fekete, Petar
    Fidri, Pavao
    JOURNAL OF HYPERTENSION, 2018, 36 : E237 - E237
  • [50] Limitations and pitfalls of non-invasive measurement of arterial pressure wave reflections and pulse wave velocity
    Segers P.
    Kips J.
    Trachet B.
    Swillens A.
    Vermeersch S.
    Mahieu D.
    Rietzschel E.
    De Buyzere M.
    Van Bortel L.
    Artery Research, 2009, 3 (2) : 79 - 88