Comparision of photo pulse plethysmography module with Mobil-O-graph for measurement of pulse wave velocity

被引:5
|
作者
Kumar, A. V. Siva [1 ]
MaheshKumar, K. [2 ]
Maruthy, K. N. [3 ]
Padmavathi, R. [4 ]
机构
[1] Sri Ramachandra Med Coll & Res Inst, Dept Physiol, Chennai 600116, Tamil Nadu, India
[2] Govt Yoga & Naturopathy Coll & Hosp, Dept Physiol & Biochem, Chennai 600104, Tamil Nadu, India
[3] Narayana Med Coll, Dept Physiol, Nellore 524003, Andhra Pradesh, India
[4] SRIHER, Sri Ramachandra Med Coll & Reserach Inst, Dept Physiol, Chennai 600116, Tamil Nadu, India
来源
CLINICAL EPIDEMIOLOGY AND GLOBAL HEALTH | 2021年 / 9卷
关键词
Pulse wave velocity; Photo pulse plethysmography; Pulse transit time; CENTRAL BLOOD-PRESSURE; ARTERIAL STIFFNESS; VALIDATION; SPHYGMOCOR; ARTERIOGRAPH; COMPLIOR; DEVICE; ECG;
D O I
10.1016/j.cegh.2020.09.001
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Introduction:Pulse wave velocity (PWV) is an indicator of arterial stiffness and one of the prognostic tools in clinical practice. We compared the finger photo pulse plethysmography (PPG) module with the Mobil-O-Graph for assessment of PWV. Material and methods: 80 healthy subjects and patients have participated in this study, among them, 42 were males, and 38 were females. Recording for the subjects was executed between 9, and 11 a.m., after a light breakfast. Lead - II ECG along with PPG were recorded in dual channel AD converter and Mobil-O-Graph simultaneously. The analogue signals of both the devices of the AD converter were digitized by using the sound card of the computer for the measurement of Pulse Transit Time [PTT]. Results: The mean age of the participants was 41.5 +/- 5.48 and BMI-26.42 +/- 5.80. PWV values measured by the devices were similar (P > 0.05). There is a significant positive correlation of PWV between PPG and Mobil O graph, r-0.92 (p = 0.001). Bland-Altman analysis indicated that a mean difference for PWV is .0.3 m/s, which is limits of agreement (1.4-2.4) between PPG and Mobil-O-Graph. Intra-class correlation (ICC) for PWV was 0.89, and the coefficient of variation (CV) was 9.2%. Conclusion: Based on the findings of the present study, we suggest that the measurement of PWV obtained from the PPG is probably a reliable one. It offers the advantages of lower cost and greater practicality about application and usage.
引用
收藏
页码:216 / 220
页数:5
相关论文
共 50 条
  • [31] Pulse Wave Velocity Measurement in Healthy and Diseased Carotid Arteries In Vivo
    Huang, Chengwu
    Su, Yuan
    Zhang, Hong
    Qian, Lin-Xue
    Luo, Jianwen
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [32] Doppler ultrasound in the measurement of pulse wave velocity: agreement with the Complior method
    Jordi Calabia
    Pere Torguet
    Maria Garcia
    Isabel Garcia
    Nadia Martin
    Bernat Guasch
    Diana Faur
    Martí Vallés
    Cardiovascular Ultrasound, 9
  • [33] The effect of measurement position on brachial-ankle pulse wave velocity
    Shimawaki, Satoshi
    Toda, Mai
    Nakabayashi, Masataka
    Sakai, Naotaka
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2015, 17 (01) : 111 - 116
  • [34] A NEW SYSTEM FOR MEASUREMENT OF THE PULSE TRANSIT TIME, THE PULSE WAVE VELOCITY AND ITS ANALYSIS
    Bereksi-Reguig, Anes.
    Bereksi-Reguig, F.
    Ali, A. Nait
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (01)
  • [35] A simplified measurement of pulse wave velocity is not inferior to standard measurement in young adults and children
    Edgell, Heather
    Stickland, Michael K.
    MacLean, Joanna E.
    BLOOD PRESSURE MONITORING, 2016, 21 (03) : 192 - 195
  • [36] Validation of a new piezo-electronic device for non-invasive measurement of arterial pulse wave velocity according to the artery society guidelines
    Morales, Margarita S.
    Cuffaro, Paula E.
    Barochiner, Jessica
    Rada, Marcelo A.
    Alfie, Jose
    Aparicio, Lucas
    Marin, Marcos
    Galarza, Carlos R.
    Waisman, Gabriel D.
    ARTERY RESEARCH, 2015, 10 : 32 - 37
  • [37] Validation of a novel and existing algorithms for the estimation of pulse transit time: advancing the accuracy in pulse wave velocity measurement
    Vardoulis, Orestis
    Papaioannou, Theodore G.
    Stergiopulos, Nikolaos
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2013, 304 (11): : H1558 - H1567
  • [38] Measurement of pulse wave velocity, augmentation index, and central pulse pressure in atrial fibrillation: a proof of concept study
    Caluwe, Rogier
    De Vriese, An S.
    Van Vlem, Bruno
    Verbeke, Francis
    JOURNAL OF THE AMERICAN SOCIETY OF HYPERTENSION, 2018, 12 (08) : 627 - 632
  • [39] Measurement of local pulse wave velocity for carotid artery by using an ultrasound-based method
    Tang, Chieh-Ju
    Lee, Po-Yang
    Chuang, Yi-Hsiang
    Huang, Chih-Chung
    ULTRASONICS, 2020, 102
  • [40] Non-contact measurement of pulse wave velocity using RGB cameras
    Nakano, Kazuya
    Aoki, Yuta
    Satoh, Ryota
    Hoshi, Akira
    Suzuki, Hiroyuki
    Nishidate, Izumi
    OPTICAL DIAGNOSTICS AND SENSING XVI: TOWARD POINT-OF-CARE DIAGNOSTICS, 2016, 9715