Comparision of photo pulse plethysmography module with Mobil-O-graph for measurement of pulse wave velocity

被引:5
|
作者
Kumar, A. V. Siva [1 ]
MaheshKumar, K. [2 ]
Maruthy, K. N. [3 ]
Padmavathi, R. [4 ]
机构
[1] Sri Ramachandra Med Coll & Res Inst, Dept Physiol, Chennai 600116, Tamil Nadu, India
[2] Govt Yoga & Naturopathy Coll & Hosp, Dept Physiol & Biochem, Chennai 600104, Tamil Nadu, India
[3] Narayana Med Coll, Dept Physiol, Nellore 524003, Andhra Pradesh, India
[4] SRIHER, Sri Ramachandra Med Coll & Reserach Inst, Dept Physiol, Chennai 600116, Tamil Nadu, India
来源
CLINICAL EPIDEMIOLOGY AND GLOBAL HEALTH | 2021年 / 9卷
关键词
Pulse wave velocity; Photo pulse plethysmography; Pulse transit time; CENTRAL BLOOD-PRESSURE; ARTERIAL STIFFNESS; VALIDATION; SPHYGMOCOR; ARTERIOGRAPH; COMPLIOR; DEVICE; ECG;
D O I
10.1016/j.cegh.2020.09.001
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Introduction:Pulse wave velocity (PWV) is an indicator of arterial stiffness and one of the prognostic tools in clinical practice. We compared the finger photo pulse plethysmography (PPG) module with the Mobil-O-Graph for assessment of PWV. Material and methods: 80 healthy subjects and patients have participated in this study, among them, 42 were males, and 38 were females. Recording for the subjects was executed between 9, and 11 a.m., after a light breakfast. Lead - II ECG along with PPG were recorded in dual channel AD converter and Mobil-O-Graph simultaneously. The analogue signals of both the devices of the AD converter were digitized by using the sound card of the computer for the measurement of Pulse Transit Time [PTT]. Results: The mean age of the participants was 41.5 +/- 5.48 and BMI-26.42 +/- 5.80. PWV values measured by the devices were similar (P > 0.05). There is a significant positive correlation of PWV between PPG and Mobil O graph, r-0.92 (p = 0.001). Bland-Altman analysis indicated that a mean difference for PWV is .0.3 m/s, which is limits of agreement (1.4-2.4) between PPG and Mobil-O-Graph. Intra-class correlation (ICC) for PWV was 0.89, and the coefficient of variation (CV) was 9.2%. Conclusion: Based on the findings of the present study, we suggest that the measurement of PWV obtained from the PPG is probably a reliable one. It offers the advantages of lower cost and greater practicality about application and usage.
引用
收藏
页码:216 / 220
页数:5
相关论文
共 50 条
  • [21] Using Bioimpedance Plethysmography for Measuring the Pulse Wave Velocity of Peripheral Vascular
    Huang, Ji-Jer
    Huang, Yang-Min
    Chang, Ming-Wen
    2016 13TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2016,
  • [22] Acoustic Plethysmography for Aortic Pulse Wave Velocity Measurement: In-Vitro and In-Vivo Feasibility Study
    Ishwarya, S.
    Kiran, V. Raj
    Manoj, Rahul
    Nabeel, P. M.
    Joseph, Jayaraj
    2024 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS, MEMEA 2024, 2024,
  • [23] Validation of a new device for photoplethysmographic measurement of multi-site arterial pulse wave velocity
    Sondej, Tadeusz
    Jannasz, Iwona
    Sieczkowski, Krzysztof
    Dobrowolski, Andrzej
    Obia, Karolina
    Targowski, Tomasz
    Olszewski, Robert
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2021, 41 (04) : 1664 - 1684
  • [24] The Method for Pulse Wave Velocity Measurement Based on Chaotic Oscillator
    Deng Chen
    Song WanQing
    2009 INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND COMPUTATIONAL INTELLIGENCE, VOL III, PROCEEDINGS, 2009, : 340 - 344
  • [25] Aortic pulse wave velocity measurement in systemic sclerosis patients
    Colaci, M.
    Giuggioli, D.
    Manfredi, A.
    Sebastiani, M.
    Coppi, F.
    Rossi, R.
    Richeldi, L.
    Ferri, C.
    REUMATISMO, 2012, 64 (06) : 360 - 367
  • [26] Measurement of pulse wave velocity in children and young adults: a comparative study using three different devices
    Kis, Eva
    Cseprekal, Orsolya
    Kerti, Andrea
    Salvi, Paolo
    Benetos, Athanase
    Tisler, Andras
    Szabo, Attila
    Tulassay, Tivadar
    Reusz, Gyoergy S.
    HYPERTENSION RESEARCH, 2011, 34 (11) : 1197 - 1202
  • [27] Measurement of pressure dependent variations in local pulse wave velocity within a cardiac cycle from forward travelling pulse waves
    Manoj, Rahul
    Raj, Kiran V.
    Nabeel, P. M.
    Sivaprakasam, Mohanasankar
    Joseph, Jayaraj
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [28] Measurement variation of aortic pulse wave velocity in the elderly
    Sutton-Tyrrell, K
    Mackey, RH
    Holubkov, R
    Vaitkevicius, PV
    Spurgeon, HA
    Lakatta, EG
    AMERICAN JOURNAL OF HYPERTENSION, 2001, 14 (05) : 463 - 468
  • [29] A Portable Device for the Measurement of Venous Pulse Wave Velocity
    Barbagini, Agata
    Ermini, Leonardo
    Pertusio, Raffaele
    Ferraresi, Carlo
    Roatta, Silvestro
    APPLIED SCIENCES-BASEL, 2022, 12 (04):
  • [30] A pulse wave velocity measurement system using USB
    Wu, Hsien-Tsai
    Lin, Chia-Hsin
    Chen, Hsuan-Kuang
    3RD INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATIONS AND CONTROL TECHNOLOGIES, VOL 3, PROCEEDINGS, 2005, : 85 - 90