Evaluating Indoor Exposure Modeling Alternatives for LCA: A Case Study in the Vehicle Repair Industry

被引:26
作者
Demou, Evangelia [1 ]
Hellweg, Stefanie [1 ]
Wilson, Michael P. [2 ]
Hammond, S. Katharine
McKone, Thomas E. [3 ]
机构
[1] ETH, Inst Environm Engn, CH-8093 Zurich, Switzerland
[2] Univ Calif Berkeley, Sch Publ Hlth, Ctr Occupat & Environm Hlth, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Lawrence Berkeley Lab, Berkeley, CA 94720 USA
关键词
TURBULENT-DIFFUSION; TRICHLOROETHYLENE; PERCHLOROETHYLENE; INHALATION; POLLUTANT; CHEMICALS;
D O I
10.1021/es803551y
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We evaluated three exposure models with data obtained from measurements among workers who use "aerosol" solvent products in the vehicle repair industry and with field experiments using these products to simulate the same exposure conditions. The three exposure models were the (1) homogeneously mixed-one-box model, (2) multizone model, and (3) eddy-diffusion model. Temporally differentiated real-time breathing zone volatile organic compound (VOC) concentration measurements, integrated far-field area samples, and simulated experiments were used in estimating parameters, such as emission rates, diffusivity, and near-field dimensions. We assessed differences in model input requirements and their efficacy for predictive modeling. The One-box model was not able to resemble the temporal profile of exposure concentrations, but it performed well concerning time-weighted exposure over extended time periods. However, this model required an adjustment for spatial concentration gradients. Multizone models and diffusion-models may solve this problem. However, we found that the reliable use of both these models requires extensive field data to appropriately define pivotal parameters such as diffusivity or near-field dimensions. We conclude that it is difficult to apply these models for predicting VOC exposures in the workplace, However, for comparative exposure scenarios in life-cycle assessment they may be useful.
引用
收藏
页码:5804 / 5810
页数:7
相关论文
共 43 条
  • [1] Hepatotoxicity associated with overexposure to 1,1-dichloro-2,2,2-trifluoroethane (HCFC-123)
    Boucher, R
    Hanna, C
    Rusch, GM
    Stidham, D
    Swan, E
    Vazquez, M
    [J]. AIHA JOURNAL, 2003, 64 (01): : 68 - 79
  • [2] Beliefs and practices in the assessment of workplace pollutants
    Bruzzi, R
    Vernez, D
    Droz, PO
    De Batz, A
    [J]. SOZIAL-UND PRAVENTIVMEDIZIN, 2006, 51 (01): : 5 - 13
  • [3] BRUZZI RAFAELLA., 2007, New developments and applications in modelling occupational exposure to airborne contaminants
  • [4] Validation of a new method for structured subjective assessment of past concentrations
    Cherrie, JW
    Schneider, T
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 1999, 43 (04) : 235 - 245
  • [5] MIXING OF A POINT-SOURCE INDOOR POLLUTANT BY FORCED-CONVECTION
    DRESCHER, AC
    LOBASCIO, C
    GADGIL, AJ
    NAZAROFF, WW
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1995, 5 (03): : 204 - 214
  • [6] DRIVAS P, 1972, ENVIRON SCI TECHNOL, V6, P733
  • [7] Modeling indoor air exposure from short-term point source releases
    Drivas, PJ
    Valberg, PA
    Murphy, BL
    Wilson, R
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1996, 6 (04): : 271 - 277
  • [8] HEINSOHN R, 1991, IND VENTILATION ENG, P699
  • [9] Confronting workplace exposure to chemicals with LCA:: Examples of trichloroethylene and perchloroethylene in metal degreasing and dry cleaning
    Hellweg, S
    Demou, E
    Scheringer, M
    McKone, TE
    Hungerbühler, K
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (19) : 7741 - 7748
  • [10] Integrating Human Indoor Air Pollutant Exposure within Life Cycle Impact Assessment
    Hellweg, Stefanie
    Demou, Evangelia
    Bruzzi, Raffaella
    Meijer, Arien
    Rosenbaum, Ralph K.
    Huijbregts, Mark A. J.
    McKone, Thomas E.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (06) : 1670 - 1679