Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife:: Marker placement and early results

被引:107
作者
Nuyttens, J. J.
Prevost, J. -B.
Praag, J.
Hoogeman, M.
Van Klaveren, R. J.
Levendag, P. C.
Pattynama, P. M. T.
机构
[1] Erasmus MC, Dr Daniel Den Hoed Canc Ctr, Dept Radiat Oncol, NL-3008 AE Rotterdam, Netherlands
[2] Erasmus MC, Dr Daniel Den Hoed Canc Ctr, Dept Pulmonol, NL-3008 AE Rotterdam, Netherlands
[3] Erasmus MC, Dr Daniel Den Hoed Canc Ctr, Dept Intervent Radiol, NL-3008 AE Rotterdam, Netherlands
关键词
D O I
10.1080/02841860600902205
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Lung tumor tracking during stereotactic radiotherapy with the CyberKnife requires the insertion of markers in or close to the tumor. To reduce the risk of pneumothorax, three methods of marker placement were used: 1) intravascular coil placement, 2) percutaneous intrathoracal, and 3) percutaneous extrathoracal placement. We investigated the toxicity of marker placement and the tumor response of the lung tumor tracking treatment. Markers were placed in 20 patients with 22 tumors: 13 patients received a curative treatment, seven a palliative. The median Charlson Comorbidity Score was 4 (range: 1 - 8). Platinum fiducials and intravascular embolisation coils were used as markers. In total, 78 markers were placed: 34 intrathoracal, 23 intravascular and 21 extrathoracal. The PTV equaled the GTV + 5 mm. A median dose of 45 Gy (range: 30 - 60 Gy, in 3 fractions) was prescribed to the 70 - 85% isodose. The response was evaluated with a CTscan performed 6 - 8 weeks after the last treatment and routinely thereafter. The median follow-up was 4 months (range: 2 - 11). No severe toxicity due to the marker placement was seen. Pneumothorax was not seen. The local control was 100%. Four tumors in four patients showed a complete response, 15 tumors in 14 patients a partial response, and three tumors in two patients with metastatic disease had stable disease. No severe toxicity of marker placement was seen due to the appropriate choice of one of the three methods. CyberKnife tumor tracking with markers is feasible and resulted in excellent tumor response. Longer follow-up is needed to validate the local control.
引用
收藏
页码:961 / 965
页数:5
相关论文
共 23 条
  • [21] Extracranial stereotactic radioablation - Results of a phase I study in medically inoperable stage I non-small cell lung cancer
    Timmerman, R
    Papiez, L
    McGarry, R
    Likes, L
    DesRosiers, C
    Frost, S
    Williams, M
    [J]. CHEST, 2003, 124 (05) : 1946 - 1955
  • [22] Stereotactic radiosurgery for lung tumors: Preliminary report of a phase I trial
    Whyte, RI
    Crownover, R
    Murphy, MJ
    Martin, DP
    Rice, TW
    DeCamp, MM
    Rodebaugh, R
    Weinhous, MS
    Le, QT
    [J]. ANNALS OF THORACIC SURGERY, 2003, 75 (04) : 1097 - 1101
  • [23] Stereotactic radiotherapy of extracranial targets:: CT-simulation and accuracy of treatment in the stereotactic body frame
    Wulf, J
    Hädinger, U
    Oppitz, U
    Olshausen, B
    Flentje, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2000, 57 (02) : 225 - 236