Self-made cryopreservative fibrin glue applied in pterygium surgery: a novel practical technique

被引:2
|
作者
Gong, Jing-Wen [1 ,2 ]
Chen, Jun-Hao [1 ,2 ]
Shen, Ting [1 ,2 ]
Jiang, Jin [1 ,2 ]
机构
[1] Zhejiang Prov Peoples Hosp, Dept Ophthalmol, 158 Shangtang Rd, Hangzhou 310014, Zhejiang, Peoples R China
[2] Peoples Hosp, Hangzhou Med Coll, Hangzhou 310014, Zhejiang, Peoples R China
关键词
Fibrin glue; Self-made cryopreservation; Pterygium; Subpackage; Commercial kit; CONJUNCTIVAL AUTOGRAFT FIXATION; AUTOLOGOUS BLOOD; FOLLOW-UP; CONTROLLED-TRIAL; PASTE METHOD; EXCISION; SUTURES; SEALANT; CUT; INFECTION;
D O I
10.1007/s10792-017-0629-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To introduce a novel practical technique of self-made cryopreservative fibrin glue (SMC) applied in pterygium surgery and to assess its safety and efficacy. Forty-eight eyes of 48 patients with nasal primary pterygium were enrolled. The patients were equally assigned to 6 groups. Self-made fibrin glue was subpackaged and, respectively, cryopreserved for 3, 7, 15 days and 1, 2 and 3 months. At each time point, the asepsis of SMC was confirmed by bacterial culture and colony counting. In each group, corresponding SMC was applied to fix the autograft after the pterygium was removed (e.g., SMC 3d for group 1 and SMC 3m for group 6). All the patients were followed up postoperatively on days 1, 3, 7 and 14 and then at months 1, 3, 6. The main outcome measures included fixation success rate within two tries, postoperative discomfort, recurrence rate and complications. No colony growth was observed in all the fibrinogen and thrombin tubes sent. Five patients needed a second try with respective SMC during the autograft fixation, and there were no significant differences in SMC use times among the groups (P = 0.885). There were no significant differences in postoperative discomfort (day 1, 3, 7; P = 0.651, P = 0.269, P = 0.180, respectively) among the groups. By the end of 6-m follow-up, no infections and severe complications were observed in any group. The total recurrence rate was 3/48 (6%), and there were no significant differences in recurrences among the groups (P = 1.000). SMC is safe and effective for autograft fixation in pterygium surgery. This new practical technique will benefit the patients and surgeons in developing and underdeveloped country.
引用
收藏
页码:1295 / 1300
页数:6
相关论文
共 50 条
  • [41] A Novel Technique of Sutureless and Glueless Conjunctival Autografting in Pterygium Surgery by Electrocautery Pen
    Xu, Fan
    Li, Min
    Yan, Yumei
    Lu, Kewei
    Cui, Ling
    Chen, Qi
    CORNEA, 2013, 32 (03) : 290 - 295
  • [42] A novel interlamellar oral mucosa graft surgery technique using fibrin glue for the treatment of trichiasis
    Binotti, William W.
    de Aguiar, Ana Carla B.
    Barbosa, Aline A.
    Burnier, Sergio, V
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2023, 86 (01) : 52 - 59
  • [43] Comparison of Fibrin Glue versus Suture for Conjunctival Autografting in Pterygium Surgery: A Meta-Analysis
    Pan, Hong-Wei
    Zhong, Jing-Xiang
    Jing, Chun-Xia
    OPHTHALMOLOGY, 2011, 118 (06) : 1049 - 1054
  • [44] Recurrence Rate and Graft Stability With Fibrin Glue Compared With Suture and Autologous Blood Coagulum for Conjunctival Autograft Adherence in Pterygium Surgery: A Meta-Analysis
    Maiti, Rituparna
    Mukherjee, Somnath
    Hota, Debasish
    CORNEA, 2017, 36 (10) : 1285 - 1294
  • [45] Efficacy of fibrin glue versus sutures for attaching conjunctival autografts in pterygium surgery: a systematic review with meta-analysis and trial sequential analysis of evidence
    Lan, Aihua
    Xiao, Feifan
    Wang, Yun
    Luo, Zhen
    Cao, Qixin
    ONCOTARGET, 2017, 8 (25) : 41487 - 41497
  • [46] Cauterisation versus fibrin glue for conjunctival autografting in primary pterygium surgery (CAGE CUP): study protocol of a randomised controlled trial
    Lesin, Mladen
    Paradzik, Martina
    Lovric, Josipa Marin
    Olujic, Ivana
    Ljubic, Zana
    Vucinovic, Ana
    Bucan, Kajo
    Puljak, Livia
    BMJ OPEN, 2018, 8 (06):
  • [47] Cost-Effective Surgical Management of Pterygium: A Blood-Based Adhesion Technique Substituting Fibrin Glue
    Yan, Audrey
    Meng, Ryan
    O'Doherty, Casey
    Wan, Leo
    Gounder, Ramakumar N.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [48] Autologous blood versus fibrin glue for conjunctival autograft adherence in sutureless pterygium surgery: a randomised controlled trial
    Kurian, Abraham
    Reghunadhan, Iodine
    Nair, K. G. R.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (04) : 464 - 470
  • [49] Patch-and-Glue Novel Technique in Bronchoesophageal Fistula Repair and Broncholith Removal With Stent and Fibrin Glue
    Wong, An-Kwok Ian
    McDonald, April
    Jones, Brittany
    Berkowitz, David
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2021, 28 (03) : E45 - E49
  • [50] A Novel Non-Gas Endospray for Applying Fibrin Glue in Laparoscopic Surgery
    Tsutsumi, Norifumi
    Sakaguchi, Yoshihisa
    Kusumoto, Tetsuya
    Ikejiri, Koji
    Tsutsumi, Ryosuke
    Kimura, Koichi
    Maekawa, Soichiro
    JOURNAL OF INVESTIGATIVE SURGERY, 2020, 33 (04) : 359 - 364