Comparison of ring artifact correction methods for flat-detector CT

被引:125
作者
Prell, Daniel [1 ]
Kyriakou, Yiannis [1 ]
Kalender, Willi A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
关键词
D O I
10.1088/0031-9155/54/12/018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In flat-detector CT, imperfect or defect detector elements may cause concentric ring artifacts due to their continuous over-or underestimation of attenuation values, which often disturb image quality. Especially due to the demand for high-spatial resolution images and the necessary pixel read-out without arbitrary pixel-binning, ring artifacts become more pronounced and the reduction of these artifacts becomes a necessity. We here present a comparison of two dedicated ring artifact correction methods for flat-detector CT, on the basis of different median and mean filterings of the reconstructed image but each working in different geometric planes. While the first method works in Cartesian coordinates, the second method performs a transformation to polar coordinates. Both post-processing methods efficiently reduce ring artifacts in the reconstructed images and improve image quality. The transformation to polar coordinates turned out to be a necessary step for efficient ring artifact correction, since correction in Cartesian coordinates suffers from newly introduced artifacts as well as insufficient correction of artifacts close to the center of rotation.
引用
收藏
页码:3881 / 3895
页数:15
相关论文
共 9 条
[1]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[2]  
Kalender W.A., 2005, COMPUT TOMOGR, V2nd
[3]   X-RAY MICROTOMOGRAPHY ON BEAMLINE-X AT SSRL [J].
KINNEY, JH ;
JOHNSON, QC ;
NICHOLS, MC ;
BONSE, U ;
SAROYAN, RA ;
NUSSHARDT, R ;
PAHL, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :2471-2474
[4]  
LAI CM, 2000, Patent No. 6115445
[5]   OPTIMAL SHORT SCAN CONVOLUTION RECONSTRUCTION FOR FANBEAM CT [J].
PARKER, DL .
MEDICAL PHYSICS, 1982, 9 (02) :254-257
[6]  
Riess T, 2004, PHYS MEDICA, V20, P43
[7]  
SCHIWIETZ T, 2007, P SPIE, V6510
[8]   Reduction of ring artefacts in high resolution micro-CT reconstructions [J].
Sijbers, J ;
Postnov, A .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14) :N247-N253
[9]   Low contrast 3D-reconstruction from C-arm data [J].
Zellerhoff, M ;
Scholz, B ;
Rührnschopf, EP ;
Brunner, T .
MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 :646-655