Fate of distal aorta after acute type A aortic dissection repair: Change and persistency of postoperative false lumen status

被引:12
|
作者
Lin, Fang-Yi [1 ,2 ]
Tseng, Yu-Hsuan [1 ,3 ]
Huang, Jiann-Woei [4 ]
Hsieh, Chong-Chao [4 ]
Chen, Huai-Min [4 ,5 ]
Chiu, Chaw-Chi [4 ]
Chen, Ying-Fu [4 ,5 ,6 ]
机构
[1] Kaohsiung Med Univ, Sch Med, Kaohsiung, Taiwan
[2] Changhua Christian Hosp, Dept Gen Med, Changhua, Taiwan
[3] Chang Gung Mem Hosp, Dept Gen Med, Kaohsiung, Taiwan
[4] Kaohsiung Med Univ Hosp, Div Cardiovasc Surg, Kaohsiung, Taiwan
[5] Kaohsiung Med Univ, Grad Inst Med, Kaohsiung, Taiwan
[6] Sin Lau Christian Hosp, Tainan, Taiwan
关键词
Aortic dissection; False lumen; Patency; Aortic diameter; Growth; Computed tomography; INTERNATIONAL REGISTRY; THORACIC AORTA; B DISSECTION; GROWTH-RATE; SURGERY; DIAMETER; IRAD; MANAGEMENT; THROMBOSIS; PREDICTOR;
D O I
10.1016/j.ijcard.2018.01.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The role of false lumen patency related to aortic growth, re-interventions, and post-discharge mortality in the chronic phase of repaired type A acute aortic dissection (TAAAD) remains controversial. We investigated the role of postoperative false lumen patency during long-term follow-up. Methods: Based on postoperative CT images of 70 candidates, 58 eligible patients without alteration of false lumen statuswere assigned into three groups: complete patency, partial patency, and complete thrombosis. Aortic growth of 7 levels was analyzed. Results: Persistent complete patency in post-operative TAAAD presents faster expansion of aortic diameter (95% CI, 0.35 to 11.52; P = 0.038; B = 5.935) and more patients with growth rate > 5 mm/year (P = 0.029). The persistent status of false lumen does not predict post-discharge mortality (P = 0.479). History of coronary artery disease (CAD) is the only independent predictor of post-discharge mortality. Conclusions: In TAAAD patients without change of postoperative false lumen status, completely patent false lumen presents faster aortic growth and more patients with growth rate > 5 mm/year. False lumen status does not correlate with late survival. Here we provide an insight into persistent postoperative false lumen in TAAAD patients and may help cast light on aortic dissection in this specific subgroup to improve their late outcomes. (c) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 55
页数:6
相关论文
共 50 条
  • [1] Fate of the Patent False Lumen of the Descending Aorta After Surgical Treatment for Acute Type 1 Aortic Dissection
    Yasar, Emre
    Duman, Zihni Mert
    Timur, Baris
    Bayram, Muhammed
    Kaplan, Mustafa Can
    Kadirogullari, Ersin
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2023, 38 (06)
  • [2] Fate of the distal aorta after surgical repair of acute DeBakey type I aortic dissection: A review
    Kirsch, Matthias
    Legras, Antoine
    Bruzzi, Matthieu
    Louis, Nicolas
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2011, 104 (02) : 125 - 130
  • [3] Postoperative Changes in the Distal Residual Aorta after Surgery for Acute Type A Aortic Dissection: Impact of False Lumen Patency and Size of Descending Aorta
    Leontyev, Sergey
    Haag, Felix
    Davierwala, Piroze M.
    Lehmkuhl, Lukas
    Borger, Michael A.
    Etz, Christian D.
    Misfeld, Martin
    Gutberlet, Matthias
    Mohr, Friedrich W.
    THORACIC AND CARDIOVASCULAR SURGEON, 2017, 65 (02) : 90 - 98
  • [4] Midterm Change of Descending Aortic False Lumen After Repair of Acute Type I Dissection
    Park, Kay-Hyun
    Lim, Cheong
    Choi, Jin Ho
    Chung, Euisuk
    Choi, Sang Il
    Chun, Eun Ju
    Sung, Kiick
    ANNALS OF THORACIC SURGERY, 2009, 87 (01) : 103 - 108
  • [5] Repair of an acute type A dissection: Fate of the remnant false lumen and preserved aortic valve
    Moriyama, Y
    Yotsumoto, G
    Masuda, H
    Iguro, Y
    Watanabe, S
    Hisatomi, K
    Toda, R
    Shimokawa, S
    Toyohira, H
    Taira, A
    SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1999, 29 (05): : 413 - 418
  • [6] Repair of an acute type a dissection: Fate of the remnant false lumen and preserved aortic valve
    Yukinori Moriyama
    Goichi Yotsumoto
    Hiroshi Masuda
    Yosihumi Iguro
    Shunichi Watanabe
    Koichi Hisatomi
    Riichiro Toda
    Shinji Shimokawa
    Hitoshi Toyohira
    Akira Taira
    Surgery Today, 1999, 29 : 413 - 418
  • [7] Acute type A aortic dissection and the consequences of a patent false lumen
    White, Abigail
    Bozso, Sabin J.
    Ouzounian, Maral
    Chu, Michael W. A.
    Moon, Michael C.
    JTCVS TECHNIQUES, 2021, 9 : 1 - 8
  • [8] Fate of descending aorta after acute type A aortic dissection repair
    Kim, Wan Kee
    Kim, Tae-Hoon
    Lee, Ha
    Song, Suk-Won
    Yoo, Kyung-Jong
    JOURNAL OF THORACIC DISEASE, 2023, 15 (11) : 5942 - +
  • [9] The effect of postoperative anticoagulation on false lumen patency after surgery for acute type A aortic dissection
    Mårten Larsson
    Gracijela Bozovic
    Johan Sjögren
    Igor Zindovic
    Sigurdur Ragnarsson
    Shahab Nozohoor
    Journal of Cardiothoracic Surgery, 16
  • [10] The effect of postoperative anticoagulation on false lumen patency after surgery for acute type A aortic dissection
    Larsson, Marten
    Bozovic, Gracijela
    Sjogren, Johan
    Zindovic, Igor
    Ragnarsson, Sigurdur
    Nozohoor, Shahab
    JOURNAL OF CARDIOTHORACIC SURGERY, 2021, 16 (01)