Determination of mercury in river water by diffusive gradients in thin films using P81 membrane as binding layer

被引:34
作者
Colaco, Camila Destro [1 ,2 ]
Marques Yabuki, Lauren Nozomi [1 ,2 ]
Rolisola, Ana Marta [1 ,2 ]
Menegario, Arnaud Antonio [2 ]
de Almeida, Eduardo [3 ]
Suarez, Carlos Alfredo [2 ]
Gao, Yue [4 ]
Corns, Warren T. [5 ]
do Nascimento Filho, Virgilio Franco [3 ]
机构
[1] Univ Estadual Paulista, UNESP, Inst Geociencias & Ciencias Exatas, Programa Posgrad Geociencias & Meio Ambiente, BR-13506900 Rio Claro, SP, Brazil
[2] Univ Estadual Paulista, UNESP, Ctr Estudos Ambientais, BR-13506900 Rio Claro, SP, Brazil
[3] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13416000 Piracicaba, SP, Brazil
[4] Vrije Univ Brussel, Dept Analyt & Environm Chem, B-1050 Brussels, Belgium
[5] PS Analyt, Orpington BR2 9SQ, Kent, England
基金
巴西圣保罗研究基金会;
关键词
Mercury; Labile; Diffusive gradients in thin films technique (DGT); P81; membrane; Cold vapor atomic florescence spectrometry; IN-SITU MEASUREMENT; TRACE-METALS; AQUATIC SYSTEMS; FRESH-WATER; SPECIATION MEASUREMENTS; DGT; SAMPLERS; ULTRAFILTRATION; COEFFICIENTS; AGAROSE;
D O I
10.1016/j.talanta.2014.05.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a device based on diffusive gradients in thin films (DGT) was evaluated for the determination of Hg(II) in river water. The DGT device was assembled with a cellulose phosphate ion exchange membrane (P81 Whatman) as a binding phase and agarose gel 1.5% (m/v) as a diffusive layer. Laboratory deployments showed that the binding of Hg2+ ([Hg-DGT]/[Hg-solution]) by P81 membrane was more effective (97%) than the Chelex 100 resin (80%).The effect of ionic strength, pH and potential interfering ions on Hg binding with DGT's was investigated. The results showed no significant effect on the binding of Hg(II) at pH range from 3.5 to 8.5 and at an ionic strength range from 0.0005 to 0.1 mol L-1. Uptakes of 50 mu g L-1 Hg(II) by P81 membrane were not affected by Fe, Mn, Zn, Cu, Ca and Mg at the concentration range of 200-1800 mu g L-1. Finally, the DGT device using the P81 as the binding layer was applied for in situ measurements of Hg in river water. For in situ measurements, the labile Hg concentration (from <2 to 13 ng L-1) was lower than 10% of the dissolved fraction (from 155 to 446 ng L-1). (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:417 / 421
页数:5
相关论文
共 38 条
[1]  
Alfaro-De la Torre MC, 2000, ANAL CHIM ACTA, V418, P53, DOI 10.1016/S0003-2670(00)00946-6
[2]   Evaluation of the Chemcatcher and DGT passive samplers for monitoring metals with highly fluctuating water concentrations [J].
Allan, Ian J. ;
Knutsson, Jesper ;
Guigues, Nathalie ;
Mills, Graham A. ;
Fouillac, Anne-Marie ;
Greenwood, Richard .
JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (07) :672-681
[3]  
[Anonymous], 1992, STANDARD METHODS EXA
[4]  
Chen H, 2011, CHEM RES CHINESE U, V27, P703
[5]   Measurements of dissolved methylmercury in natural waters using diffusive gradients in thin film (DGT) [J].
Clarisse, Olivier ;
Hintelmann, Holger .
JOURNAL OF ENVIRONMENTAL MONITORING, 2006, 8 (12) :1242-1247
[6]   DIFFUSION COEFFICIENTS OF METALS IN NON-CONVENTIONAL MATERIALS (AGAROSE AND CELLULOSE ACETATE) USED IN THE DIFFUSIVE GRADIENTS IN THIN FILMS TECHNIQUE [J].
Colaco, Camila Destro ;
Marques Yabuki, Lauren Nozomi ;
Alcantara, Amanda Lodovico ;
Menegario, Amauri Antonio .
QUIMICA NOVA, 2012, 35 (07) :1360-1364
[7]   Progress in understanding the use of diffusive gradients in thin films (DGT) - back to basics [J].
Davison, William ;
Zhang, Hao .
ENVIRONMENTAL CHEMISTRY, 2012, 9 (01) :1-13
[8]   Paper-based diffusive gradients in thin films technique coupled to energy dispersive X-ray fluorescence spectrometry for the determination of labile Mn, Co, Ni, Cu, Zn and Pb in river water [J].
de Almeida, Eduardo ;
do Nascimento Filho, Virgilio Franco ;
Menegario, Amauri Antonio .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 :70-74
[9]   Determination of labile barium in petroleum-produced formation water using paper-based DGT samplers [J].
de Oliveira, Wellington ;
Batista de Carvalho, Maria de Fatima ;
de Almeida, Eduardo ;
Menegario, Amauri Antonio ;
Domingos, Roberto Naves ;
Brossi-Garcia, Ana Luiza ;
do Nascimento Filho, Virgilio Franco ;
Santelli, Ricardo Erthal .
TALANTA, 2012, 100 :425-431
[10]   In situ measurements of labile Cu, Cd and Mn in river waters using DGT [J].
Denney, S ;
Sherwood, J ;
Leyden, J .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 239 (1-3) :71-80