Prevention of Peritendinous Adhesions Using an Electrospun DegraPol Polymer Tube: A Histological, Ultrasonographic, and Biomechanical Study in Rabbits

被引:29
作者
Buergisser, Gabriella Meier [1 ]
Calcagni, Maurizio [1 ]
Mueller, Angela [1 ]
Bonavoglia, Eliana [2 ]
Fessel, Gion [3 ]
Snedeker, Jess G. [3 ]
Giovanoli, Pietro [1 ]
Buschmann, Johanna [1 ]
机构
[1] Univ Zurich Hosp, Div Plast Surg & Hand Surg, ZKF, CH-8091 Zurich, Switzerland
[2] Ab Med, I-20020 Milan, Italy
[3] Uniklin Balgrist, Dept Orthoped, CH-8008 Zurich, Switzerland
关键词
TENDON RUPTURE REPAIR; ACHILLES-TENDON; FLEXOR TENDONS; MOTION; WEIGHTBEARING; MEMBRANE; SURGERY; TISSUE; RANGE; ANKLE;
D O I
10.1155/2014/656240
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. One of the great challenges in surgical tendon rupture repair is to minimize peritendinous adhesions. In order to reduce adhesion formation, a physical barrier was applied to a sutured rabbit Achilles tendon, with two different immobilization protocols used postoperatively. Methods. Thirty New Zealand white rabbits received a laceration on the Achilles tendon, sutured with a 4-strand Becker suture, and half of the rabbits got a DegraPol tube at the repair site. While fifteen rabbits had their treated hind leg in a 180 degrees stretched position during 6 weeks (adhesion provoking immobilization), the other fifteen rabbits were recasted with a 150 degrees position after 3 weeks (adhesion inhibiting immobilization). Adhesion extent was analysed macroscopically, via ultrasound and histology. Inflammation was determined histologically. Biomechanical properties were analysed. Results. Application of a DegraPol tube reduced adhesion formation by approximately 20%-independently of the immobilization protocol. Biomechanical properties of extracted specimen were not affected by the tube application. There was no serious inflammatory reaction towards the implant material. Conclusions. Implantation of a DegraPol tube tightly set around a sutured tendon acts as a beneficial physical barrier and prevents adhesion formation significantly-without affecting the tendon healing process.
引用
收藏
页数:11
相关论文
共 45 条
  • [41] Wray Walter H 3rd, 2009, Foot Ankle Spec, V2, P214, DOI 10.1177/1938640009346449
  • [42] AN EXPERIMENTAL STUDY OF THE EFFECT OF CORTISONE ON THE HEALING PROCESS AND TENSILE STRENGTH OF TENDONS
    WRENN, RN
    GOLDNER, JL
    MARKEE, JL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) : 588 - 601
  • [43] Tendon Healing, Edema, and Resistance to Flexor Tendon Gliding: Clinical Implications
    Wu, Ya Fang
    Tang, Jin Bo
    [J]. HAND CLINICS, 2013, 29 (02) : 167 - +
  • [44] Evaluation of resorbable barrier for preventing surgical adhesions
    Zhang, CL
    Tian, WM
    Cui, FZ
    [J]. CURRENT APPLIED PHYSICS, 2005, 5 (05) : 411 - 416
  • [45] Collagen membrane alleviates peritendinous adhesion in the rat Achilles tendon injury model
    Zhao Huan
    Guan Hong-geng
    Gu Jun
    Luo Zong-ping
    Zhang Wen
    Chen Bing
    Gu Qiao-li
    Yang Hui-lin
    Shi Qin
    [J]. CHINESE MEDICAL JOURNAL, 2013, 126 (04) : 729 - 733