Prevention of Peritendinous Adhesions Using an Electrospun DegraPol Polymer Tube: A Histological, Ultrasonographic, and Biomechanical Study in Rabbits

被引:29
|
作者
Buergisser, Gabriella Meier [1 ]
Calcagni, Maurizio [1 ]
Mueller, Angela [1 ]
Bonavoglia, Eliana [2 ]
Fessel, Gion [3 ]
Snedeker, Jess G. [3 ]
Giovanoli, Pietro [1 ]
Buschmann, Johanna [1 ]
机构
[1] Univ Zurich Hosp, Div Plast Surg & Hand Surg, ZKF, CH-8091 Zurich, Switzerland
[2] Ab Med, I-20020 Milan, Italy
[3] Uniklin Balgrist, Dept Orthoped, CH-8008 Zurich, Switzerland
关键词
TENDON RUPTURE REPAIR; ACHILLES-TENDON; FLEXOR TENDONS; MOTION; WEIGHTBEARING; MEMBRANE; SURGERY; TISSUE; RANGE; ANKLE;
D O I
10.1155/2014/656240
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. One of the great challenges in surgical tendon rupture repair is to minimize peritendinous adhesions. In order to reduce adhesion formation, a physical barrier was applied to a sutured rabbit Achilles tendon, with two different immobilization protocols used postoperatively. Methods. Thirty New Zealand white rabbits received a laceration on the Achilles tendon, sutured with a 4-strand Becker suture, and half of the rabbits got a DegraPol tube at the repair site. While fifteen rabbits had their treated hind leg in a 180 degrees stretched position during 6 weeks (adhesion provoking immobilization), the other fifteen rabbits were recasted with a 150 degrees position after 3 weeks (adhesion inhibiting immobilization). Adhesion extent was analysed macroscopically, via ultrasound and histology. Inflammation was determined histologically. Biomechanical properties were analysed. Results. Application of a DegraPol tube reduced adhesion formation by approximately 20%-independently of the immobilization protocol. Biomechanical properties of extracted specimen were not affected by the tube application. There was no serious inflammatory reaction towards the implant material. Conclusions. Implantation of a DegraPol tube tightly set around a sutured tendon acts as a beneficial physical barrier and prevents adhesion formation significantly-without affecting the tendon healing process.
引用
收藏
页数:11
相关论文
共 2 条
  • [1] Prevention of peritendinous adhesions with electrospun poly (lactic acid-co-glycolic acid) (PLGA) bioabsorbable nanofiber: An experimental study
    Uyanik, Orkun
    Pekkoc-Uyanik, Kubra Cigdem
    Findik, Siddika
    Avci, Ahmet
    Altuntas, Zeynep
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2022, 209
  • [2] Prevention of peritendinous adhesions with electrospun poly (lactic acid-co-glycolic acid) (PLGA) bioabsorbable nanofiber: An experimental study
    Uyanik, Orkun
    Pekkoc-Uyanik, Kubra Cigdem
    Findik, Siddika
    Avci, Ahmet
    Altuntas, Zeynep
    Colloids and Surfaces B: Biointerfaces, 2022, 209