Megahertz ultra-wide-field swept-source retina optical coherence tomography compared to current existing imaging devices

被引:51
作者
Reznicek, Lukas [1 ]
Klein, Thomas [2 ]
Wieser, Wolfgang [2 ]
Kernt, Marcus [1 ]
Wolf, Armin [1 ]
Haritoglou, Christos [1 ]
Kampik, Anselm [1 ]
Huber, Robert [2 ]
Neubauer, Aljoscha S. [1 ]
机构
[1] Univ Munich, Dept Ophthalmol, Munich, Germany
[2] Univ Munich, Fac Phys, Inst Biomol Opt, Munich, Germany
关键词
Oct; Imaging; Retinal imaging; Ultra-wide-field; Mhz OCT; FDML OCT; En face; Cross-sectional scan; Swept source; DOMAIN MODE-LOCKING; MACULAR DEGENERATION; LASER; RANIBIZUMAB; OCT; QUALITY;
D O I
10.1007/s00417-014-2640-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To investigate the image quality of wide-angle cross-sectional and reconstructed fundus images based on ultra-megahertz swept-source Fourier domain mode locking (FDML) OCT compared to current generation diagnostic devices. Methods A 1,050 nm swept-source FDML OCT system was constructed running at 1.68 MHz A-scan rate covering approximately 70 degrees field of view. Twelve normal eyes were imaged with the device applying an isotropically dense sampling protocol (1,900x1,900 A-scans) with a fill factor of 100 %. Obtained OCT scan image quality was compared with two commercial OCT systems (Heidelberg Spectralis and Stratus OCT) of the same 12 eyes. Reconstructed en-face fundus images from the same FDML-OCT data set were compared to color fundus, infrared and ultra-wide-field scanning laser images (SLO). Results Comparison of cross-sectional scans showed a high overall image quality of the 15x averaged FDML images at 1.68 MHz [overall quality grading score: 8.42 +/- 0.52, range 0 (bad)-10 (excellent)] comparable to current spectral-domain OCTs (overall quality grading score: 8.83 +/- 0.39, p=0.731). On FDML OCT, a dense 3D data set was obtained covering also the central and mid-peripheral retina. The reconstructed FDML OCT en-face fundus images had high image quality comparable to scanning laser ophthalmoscope (SLO) as judged from retinal structures such as vessels and optic disc. Overall grading score was 8.36 +/- 0.51 for FDML OCT vs 8.27 +/- 0.65 for SLO (p=0.717). Conclusions Ultra-wide-field megahertz 3D FDML OCT at 1.68 MHz is feasible, and provides cross-sectional image quality comparable to current spectral-domain OCT devices. In addition, reconstructed en-face visualization of fundus images result in a wide-field view with high image quality as compared to currently available fundus imaging devices. The improvement of >30x in imaging speed over commercial spectral-domain OCT technology enables high-density scan protocols leading to a data set for high quality cross-sectional and en-face images of the posterior segment.
引用
收藏
页码:1009 / 1016
页数:8
相关论文
共 23 条
[1]   FEASIBILITY OF INTRASURGICAL SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY [J].
Binder, Susanne ;
Falkner-Radler, Christiane I. ;
Hauger, Christoph ;
Matz, Holger ;
Glittenberg, Carl .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (07) :1332-1336
[2]   Ranibizumab versus verteporfin for neovascular age-related macular degeneration [J].
Brown, David M. ;
Kaiser, Peter K. ;
Michels, Mark ;
Soubrane, Gisele ;
Heier, Jeffrey S. ;
Kim, Robert Y. ;
Sy, Judy P. ;
Schneider, Susan .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (14) :1432-1444
[3]   Association between retinal thickness measured by spectral-domain optical coherence tomography (OCT) and rod-mediated dark adaptation in non-exudative age-related maculopathy [J].
Clark, Mark E. ;
McGwin, Gerald, Jr. ;
Neely, David ;
Feist, Richard ;
Mason, John O., III ;
Thomley, Martin ;
White, Milton F., Jr. ;
Ozaydin, Bunyamin ;
Girkin, Christopher A. ;
Owsley, Cynthia .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (10) :1427-1432
[4]   An optical coherence tomography-guided, variable dosing regimen with intravitreal ranibizumab (lucentis) for neovascular age-related macular degeneration [J].
Fung, Anne E. ;
Lalwani, Geeta A. ;
Rosenfeld, Philip J. ;
Dubovy, Sander R. ;
Michels, Stephan ;
Feuer, William J. ;
Puliafito, Carmen A. ;
Davis, Janet L. ;
Flynn, Harry W., Jr. ;
Esquiabro, Maria .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (04) :566-583
[5]   Projection OCT fundus imaging for visualising outer retinal pathology in non-exudative age-related macular degeneration [J].
Gorczynska, I. ;
Srinivasan, V. J. ;
Vuong, L. N. ;
Chen, R. W. S. ;
Liu, J. J. ;
Reichel, E. ;
Wojtkowski, M. ;
Schuman, J. S. ;
Duker, J. S. ;
Fujimoto, J. G. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (05) :603-609
[6]   Documentation of Intraretinal Retinal Pigment Epithelium Migration via High-Speed Ultrahigh-Resolution Optical Coherence Tomography [J].
Ho, Joseph ;
Witkin, Andre J. ;
Liu, Jonathan ;
Chen, Yueli ;
Fujimoto, James G. ;
Schuman, Joel S. ;
Duker, Jay S. .
OPHTHALMOLOGY, 2011, 118 (04) :687-693
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]   Fourier domain mode locking at 1050 nm for ultra-high-speed optical coherence tomography of the human retina at 236,000 axial scans per second [J].
Huber, R. ;
Adler, D. C. ;
Srinivasan, V. J. ;
Fujimoto, J. G. .
OPTICS LETTERS, 2007, 32 (14) :2049-2051
[9]   Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography [J].
Huber, R ;
Wojtkowski, M ;
Fujimoto, JG .
OPTICS EXPRESS, 2006, 14 (08) :3225-3237
[10]   Buffered Fourier domain mode locking: unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s [J].
Huber, Robert ;
Adler, Desmond C. ;
Fujimoto, James G. .
OPTICS LETTERS, 2006, 31 (20) :2975-2977