A Novel Method to Evaluate Precision of Optical Implant Impressions with Commercial Scan BodiesAn Experimental Approach

被引:78
作者
Fluegge, Tabea [1 ]
Att, Wael [1 ,3 ]
Metzger, Marc [2 ]
Nelson, Katja [1 ]
机构
[1] Univ Med Ctr, Dept Oral & Maxillofacial Surg, Hugstetter Str 55, D-79106 Freiburg, Germany
[2] Univ Med Ctr, Dept Oral Prosthodont, Freiburg, Germany
[3] Mohammed bin Rashid Univ Hlth & Med Sci, Dept Restorat Dent, Hamdan bin Mohammed Coll Dent Med, Dubai, U Arab Emirates
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2017年 / 26卷 / 01期
关键词
Dental implants; dental implant-supported prosthesis: dental implant; abutment connection; laser scanning; CAD; CAM; PROBE SCANNER; IN-VITRO; ACCURACY; REGISTRATION; POSITION; CASTS; FIT;
D O I
10.1111/jopr.12362
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeOptical transfer is realized with system-specific transfer posts (scan bodies) mounted on dental implants or on implant analogs. This study presents a novel algorithm for creation of geometry on the surface of dental implant scan bodies and examines the precision of the optical acquisition of scan bodies and the precision of the position of the screw-tightened scan bodies on dental implant analogs. Materials and MethodsScan bodies of two different implant manufacturers (S1, S2), one with a horizontal and two with different conical implant-abutment geometries were screw tightened to implant analogs in stone casts with a 10 Ncm torque. The stone casts were scanned ten times with a dental lab scanner. Each scan body was removed and positioned ten times; after each repositioning, a scan was performed. The cylinder axis of every scan body and the occlusal horizontal scan body surface was virtually reconstructed. At the intersection of the cylinder axis and the horizontal plane a point was marked. The mean deviation of this point in consecutive scans and the angle between the scan body axes in the virtual models were measured, and the standard deviation was calculated. Statistical significance of the results was tested with a Kruskal-Wallis Test and Mann-Whitney U-test for pairwise comparison (p < 0.05). ResultsThe mean deviation of the angle between two scan bodies was 0.05 degrees (SD 0.04 degrees) (S1) and 0.14 degrees (SD 0.08 degrees) (S2). After detachment and repositioning of the scan bodies the mean deviation was 0.05 degrees (SD 0.03 degrees) (S1) and 0.16 degrees (SD 0.08 degrees) (S2). The mean deviation of the central point was 5.7 m (SD 3.4 m) without detachment and 4.9 m (SD 2.6 m) after detachment and repositioning (S1). For system S2 the mean deviation of the central point was 13.4 m (SD 7.2 m) after repeated scanning and 15 m (SD 5 m) after detachment, repositioning, and repeated scanning. ConclusionsThe precision of extraoral scanning of scan bodies is dependent on the scan body surface design and geometry. The precision of scanning with an extraoral model scanner differed between the scan body geometries and inter-scan body distances. The precision of dental implant scan body scanning was not significantly influenced by detachment and repositioning of the scan body.
引用
收藏
页码:34 / 41
页数:8
相关论文
共 24 条
[1]  
[Anonymous], 1994, 57251 ISO, P17
[2]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[3]   Digital dentistry: an overview of recent developments for CAD/CAM generated restorations [J].
Beuer, F. ;
Schweiger, J. ;
Edelhoff, D. .
BRITISH DENTAL JOURNAL, 2008, 204 (09) :505-511
[4]  
Brunner E., 2002, Nonparametric analysis of longitudinal data in factorial experiments
[5]   Optical Three-Dimensional Scanning Acquisition of the Position of Osseointegrated Implants: An in vitro Study to Determine Method Accuracy and Operational Feasibility [J].
Del Corso, Marco ;
Aba, Giancarlo ;
Vazquez, Lydia ;
Dargaud, Jacques ;
Ehrenfest, David M. Dohan .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (03) :214-221
[6]   Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner [J].
Fluegge, Tabea V. ;
Schlager, Stefan ;
Nelson, Katja ;
Nahles, Susanne ;
Metzger, Marc C. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (03) :471-478
[7]   Manual closing torque in five implant abutment systems: An in vitro comparative study [J].
Gross, M ;
Kozak, D ;
Laufer, BZ ;
Weiss, EI .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (05) :574-578
[8]  
Holst S, 2012, INT J ORAL MAX IMPL, V27, P29
[9]   A COMPARATIVE-ANALYSIS OF THE ACCURACY OF IMPLANT TRANSFER TECHNIQUES [J].
HSU, CC ;
MILLSTEIN, PL ;
STEIN, RS .
JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (06) :588-593
[10]   Digital implant impressions with the "Individualized Scanbody Technique" for emergence profile support [J].
Joda, Tim ;
Wittneben, Julia-Gabriela ;
Braegger, Urs .