Test-retest reliability of the unsupported upper-limb exercise test (UULEX) and 6-min peg board ring test (6PBRT) in healthy adult individuals

被引:22
|
作者
Lima, Vanessa Pereira [1 ]
Velloso, Marcelo [2 ]
Almeida, Fabiana Damasceno [2 ]
Carmona, Bianca [2 ]
Ribeiro-Samora, Giane Amorim [2 ]
Janaudis-Ferreira, Tania [3 ]
机构
[1] Univ Fed Vales Jequitinhonha & Mucuri Ufvjm, Dept Phys Therapy, Diamantina, MG, Brazil
[2] Univ Fed Minas Gerais Ufmg, Dept Phys Therapy, Belo Horizonte, MG, Brazil
[3] McGill Univ, Sch Phys & Occupat Therapy, Montreal, PQ H3A 0G4, Canada
关键词
Upper extremity; exercise; reliability; endurance; COPD and exercise tolerance; OBSTRUCTIVE PULMONARY-DISEASE; BETWEEN-DAY RELIABILITY; ARM; COPD; HYPERINFLATION; GUIDELINES; AGREEMENT;
D O I
10.1080/09593985.2018.1425786
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: The unsupported upper-limb exercise (UULEX) and 6-min peg board ring tests (6PBRTs) have been developed to measure peak unsupported arm exercise capacity and arm endurance, respectively, in individuals with chronic obstructive pulmonary disease. These tests are valid and reproducible in this population; however, the reproducibility of healthy adults is currently unknown. Objective: To determine the within-day test-retest reliability of the UULEX and 6PBRT in healthy adults. Method: The study included 41 healthy adults, aged 38.3 +/- 17.9years old, who performed both tests, twice each on the same day, with a 30-min rest in between. Before and immediately after the tests, blood pressure (BP), heart rate (HR), perception of exertion, and arm fatigue were measured. Time to perform the test and number of rings moved were recorded for the UULEX and 6PBRT, respectively. Results: The UULEX was reproducible on Bland-Altman analysis with lower and upper limits of agreement: 2.40 and -2.49min, respectively (bias=-0.05; p=0.817) and intraclass correlation coefficient (ICC)=0.85 (p<0.0001) for time in minutes for the first and second tests. The 6PBRT was not reproducible on Bland-Altman analysis with lower and upper limits of agreement of 31.64 and -114.54 (bias=-41.45; p<0.0001) and ICC=0.91 (p<0.0001) for the number of rings moved. Conclusion: UULEX is a reliable test in healthy adults. Only one test is adequate when measuring peak unsupported arm exercise capacity using the UULEX in healthy adults, while more than two tests may be needed to measure arm endurance using the 6PBRT.
引用
收藏
页码:806 / 812
页数:7
相关论文
共 18 条
  • [1] Test-retest reliability of the 6-min walk test in patients with postpolio syndrome
    Skough, Katarina
    Broman, Lisbet
    Borg, Kristian
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2013, 36 (02) : 140 - 145
  • [2] Normative Values for the Unsupported Upper Limb Exercise Test and 6-Minute Pegboard and Ring Test in Healthy Canadian Adults
    Lima, Vanessa Pereira
    Brooks, Dina
    Konidis, Stacey
    Araujo, Tamara
    Ribeiro-Samora, Giane Amorim
    Goldstein, Roger
    Janaudis-Ferreira, Tania
    PHYSIOTHERAPY CANADA, 2020, 72 (04) : 330 - 336
  • [3] Test-retest reliability and correlates of the 6-min walk test in people with alcohol use disorders
    Vancampfort, Davy
    Vandael, Hannelore
    Hallgren, Mats
    Van Damme, Tine
    PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2021, 26 (03)
  • [4] Test-retest reliability of oxygen uptake kinetics-on and -off during 6-min step test in healthy men and women
    Marinho, Renan Shida
    Santos-de-Araujo, Aldair Darlan
    Kawakami, Debora Mayumi de Oliveira
    Dourado, Izadora Moraes
    Goulart, Cassia da Luz
    Bassi-Dibai, Daniela
    Roscani, Meliza Goi
    Mendes, Renata Goncalves
    Demeyer, Heleen
    Borghi-Silva, Audrey
    SPORT SCIENCES FOR HEALTH, 2025,
  • [5] Validity and reliability of the unsupported upper-limb exercise test in individuals with rheumatoid arthritis
    Cetin, Sebahat Yaprak
    Calik, Bilge Basakci
    Ayan, Ayse
    Cavlak, Ugur
    INTERNATIONAL JOURNAL OF RHEUMATIC DISEASES, 2019, 22 (11) : 2025 - 2030
  • [6] Convergent Validity and Test-Retest Reliability of the Unsupported Upper Limb Exercise Test in Patients with Chronic Neck Pain
    Karazeybek, Zeynep Busra
    Naz, Ilknur
    PERCEPTUAL AND MOTOR SKILLS, 2022, 129 (04) : 1177 - 1192
  • [7] Measurement properties of the six-minute pegboard and ring test (6PBRT) in healthy adolescents
    Leite, Hercules Ribeiro
    Queiroz, Ilkilene Pinheiro
    Santos, Julia Goncalves
    Barroso de Souza, Fernanda Lorena
    Scheidt Figueiredo, Pedro Henrique
    Lanza, Fernanda de Cordoba
    de Deus, Franciele Angelo
    Cunha Neves, Camila Danielle
    Soares, Bruno Alvarenga
    Tsopanoglou, Sabrina Pinheiro
    Lima, Vanessa Pereira
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2021, 28 : 56 - 61
  • [8] Test-retest reliability and developmental evolution of the 6-min walk test in Caucasian boys aged 5-12 years
    Goemans, Nathalie
    Klingels, Katrijn
    van den Hauwe, Marleen
    Van Orshoven, Anneleen
    Vanpraet, Sofie
    Feys, Hilde
    Buyse, Gunnar
    NEUROMUSCULAR DISORDERS, 2013, 23 (01) : 19 - 24
  • [9] Test-Retest Reliability of the 6-Minute Walk Test in Individuals With Down Syndrome
    Casey, Amanda F.
    Wang, Xu
    Osterling, Kristin
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (11): : 2068 - 2074
  • [10] Test-retest reliability of cardiopulmonary exercise test-derived metrics in individuals with COPD versus healthy controls
    Mohammad, Milan
    Thomsen, Rie S.
    Rasmussen, Iben E.
    Andersen, Amalie B.
    Hartmann, Jacob P.
    Berg, Ronan M. G.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2025, 45 (01)