Numerical evaluation of ejector-assisted mechanical compression systems for refrigeration applications

被引:45
作者
Ben Mansour, Ridha [1 ]
Ouzzane, Mohamed [1 ]
Aidoun, Zine [1 ]
机构
[1] CanmetENERGY Nat Resources Canada, Varennes, PQ, Canada
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2014年 / 43卷
关键词
Ejector; Refrigeration cycles; Modelling; Performance; Cascade; Low temperature; LOW-GRADE HEAT; COOLING SYSTEM; DESIGN; CYCLE;
D O I
10.1016/j.ijrefrig.2014.04.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
A study of the conjugate effects of ejector performance characteristics, the activation pressure temperature conditions at the generator and the interaction with the compressor on refrigeration systems was performed. Besides the conventional compression cycle which was used as a reference, three more configurations were selected for this study: a hybrid ejector compressor booster and two cascade compressor ejector cycles. The modelling methodology developed to handle such systems was based on the principles of thermodynamics and fluid dynamics and included two separate sub-cycles in constant interaction: a loop driven mechanically by a compressor, coupled with a thermally activated ejector loop. This cycle model was combined with a validated ejector model and manufacturer's compressor performance maps. A performance analysis and a parametric optimization were performed to select promising cycles. For given working conditions, substantial improvement in COP of the selected cycles over the conventional mechanical compression cycle was found. Crown Copyright (C) 2014 Published by Elsevier Ltd on behalf of the International Institute of Refrigeration. All rights reserved.
引用
收藏
页码:36 / 49
页数:14
相关论文
共 39 条
  • [1] Abdulateef J.M., 2009, RENEW SUST ENERG REV, V13, P1338
  • [2] Ablwaifa AE., 2006, THESIS NOTTINGHAM U
  • [3] Aidoun Z., 2011, 10 IEA HEAT PUMP C T
  • [4] A solar ejector cooling system using refrigerant R134a in the Athens area
    Alexis, GK
    Karayiannis, EK
    [J]. RENEWABLE ENERGY, 2005, 30 (09) : 1457 - 1469
  • [5] Aphornratana S, 1998, INT J ENERG RES, V22, P195, DOI 10.1002/(SICI)1099-114X(19980310)22:3<195::AID-ER346>3.0.CO
  • [6] 2-A
  • [7] ASHRAE, 1969, ASHRAE HDB GUID DAT, P151
  • [8] Numerical assessment of ejector operation for refrigeration applications based on CFD
    Bartosiewicz, Y
    Aidoun, Z
    Mercadier, Y
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (5-6) : 604 - 612
  • [9] Numerical and experimental investigations on supersonic ejectors
    Bartosiewicz, Y
    Aidoun, Z
    Desevaux, P
    Mercadier, Y
    [J]. INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2005, 26 (01) : 56 - 70
  • [10] SUPERSONIC-FLOW IN THE 2ND-THROAT EJECTOR-DIFFUSER SYSTEM
    CHEN, FL
    LIU, CF
    YANG, JY