Simultaneous quantification of 21 water soluble vitamin circulating forms in human plasma by liquid chromatography-mass spectrometry

被引:43
作者
Redeuil, Karine Meisser [1 ]
Longet, Karin [1 ]
Benet, Sylvie [1 ]
Munari, Caroline [2 ]
Campos-Gimenez, Esther [1 ]
机构
[1] Nestec Ltd, Nestle Res Ctr, Dept Analyt Sci, Vitamins & Phytonutrients Grp, CH-1000 Lausanne, Switzerland
[2] Nestec Ltd, CT R&D Nestle Res Ctr, CH-1000 Lausanne, Switzerland
关键词
Water soluble vitamins; Circulating forms; Human plasma; Liquid chromatography; Tandem mass spectrometry; PROTEIN-BINDING ASSAY; PANTOTHENIC-ACID; B-6; VITAMERS; DOUBLE-BLIND; FOLIC-ACID; HUMAN-MILK; SUPPLEMENTATION; PERFORMANCE; BIOTIN; FOLATE;
D O I
10.1016/j.chroma.2015.09.049
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This manuscript reports a validated analytical approach for the quantification of 21 water soluble vitamins and their main circulating forms in human plasma. Isotope dilution-based sample preparation consisted of protein precipitation using acidic methanol enriched with stable isotope labelled internal standards. Separation was achieved by reversed-phase liquid chromatography and detection performed by tandem mass spectrometry in positive electrospray ionization mode. Instrumental lower limits of detection and quantification reached <0.1-10 nM and 0.2-25 nM, respectively. Commercially available pooled human plasma was used to build matrix-matched calibration curves ranging 2-500, 5-1250, 20-5000 or 150-37500 nM depending on the analyte. The overall performance of the method was considered adequate, with 2.8-20.9% and 5.2-20.0% intra and inter-day precision, respectively and averaged accuracy reaching 91-108%. Recovery experiments were also performed and reached in average 82%. This analytical approach was then applied for the quantification of circulating water soluble vitamins in human plasma single donor samples. The present report provides a sensitive and reliable approach for the quantification of water soluble vitamins and main circulating forms in human plasma. In the future, the application of this analytical approach will give more confidence to provide a comprehensive assessment of water soluble vitamins nutritional status and bioavailability studies in humans. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 50 条
[41]   Simultaneous quantification of atenolol and chlorthalidone in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry [J].
Shah, Jaivik V. ;
Patel, Daxesh P. ;
Shah, Priyanka A. ;
Sanyal, Mallika ;
Shrivastav, Pranav S. .
BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (02) :208-216
[42]   Simultaneous Determination of Statins in Human Urine by Dilute-and-Shoot-Liquid Chromatography-Mass Spectrometry [J].
Jang, Haejong ;
Mai, Xuan-Lan ;
Lee, Gunhee ;
Ahn, Jae Hyoung ;
Rhee, Jongsook ;
Quoc-Ky Truong ;
Dinh Vinh ;
Hong, Jongki ;
Kim, Kyeong Ho .
MASS SPECTROMETRY LETTERS, 2018, 9 (04) :95-99
[43]   A simple and easy non-derivatization gas chromatography-mass spectrometry method for simultaneous quantification of valproic acid, gabapentin, pregabalin, and vigabatrin in human plasma [J].
Jin, Peng ;
You, Yu-xin ;
Zhao, Lin-lin ;
Zhao, Yan-lin ;
Zheng, Xiao-xiao ;
Du, Yan ;
Tang, Dao-quan .
JOURNAL OF SEPARATION SCIENCE, 2023, 46 (02)
[44]   Simultaneous determination and validated quantification of human insulin and its synthetic analogues in human blood serum by immunoaffinity purification and liquid chromatography-mass spectrometry [J].
Cornelius Hess ;
Andreas Thomas ;
Mario Thevis ;
Bernd Stratmann ;
Wulf Quester ;
Diethelm Tschoepe ;
Burkhard Madea ;
Frank Musshoff .
Analytical and Bioanalytical Chemistry, 2012, 404 :1813-1822
[45]   Sensitive and reproducible liquid chromatography-tandem mass spectrometry method for quantification of sibutramine in human plasma [J].
Nirogi R.V.S. ;
Kandikere V. ;
Shukla M. ;
Mudigonda K. ;
Maurya S. .
Forensic Toxicology, 2007, 25 (1) :30-36
[46]   Sensitive quantification of rifaximin in human plasma by liquid chromatography-tandem mass spectrometry [J].
Zhang, Xianhua ;
Duan, Jingli ;
Li, Ke ;
Zhou, Liya ;
Zhai, Suodi .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2) :348-355
[47]   Rapid quantification of nebivolol in human plasma by liquid chromatography coupled with electrospray ionization tandem mass spectrometry [J].
Ramakrishna, NS ;
Vishwottam, KN ;
Koteshwara, M ;
Manoj, S ;
Santosh, M ;
Varma, DP .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (05) :1006-1013
[48]   Vitamin B12 quantification in human milk - Beyond current limitations using liquid chromatography and inductively coupled plasma - Mass spectrometry [J].
Dubascoux, Stephane ;
Payot, Janique Richoz ;
Sylvain, Paul ;
Nicolas, Marine ;
Gimenez, Esther Campos .
FOOD CHEMISTRY, 2021, 362
[49]   Simultaneous determination of hydrochlorothiazide and valsartan in human plasma by liquid chromatography/tandem mass spectrometry [J].
Liu, Fei ;
Zhang, Jundong ;
Xu, Yu ;
Gao, Shu ;
Guo, Qingxiang .
ANALYTICAL LETTERS, 2008, 41 (08) :1348-1365
[50]   Liquid Chromatography/Mass Spectrometry Method for the Simultaneous Determination of Atorvastatin and Telmisartan in Human Plasma [J].
Varghese, Susheel John ;
Ravi, Thengungal Kochupappy .
ANALYTICAL CHEMISTRY LETTERS, 2019, 9 (04) :552-563