摘要
The objective of this study was to develop a sensitive and miniaturized immunoassay by coupling a microbead-based immunoassay with an interdigitated array (IDA) electrode. An IDA electrode amplifies the signal by recycling an electrochemically redox-reversible molecule. The microfabricated platinum electrodes had 25 pairs of electrodes with 1.6-mum gaps and 2.4-mum widths. An enzyme-labeled sandwich immunoassay on paramagnetic microbeads with mouse IgG as the analyte and beta-galactosidase as the enzyme label was used as the model system. beta-Galactosidase converted p-aminophenyl beta-D-galactopyranoside to p-aminophenol (PAP). This enzyme reaction was measured continuously by positioning the microbeads near the electrode surface with a magnet. Electrochemical recycling occurred with PAP oxidation to p-quinone imine (PQI) at +290 mV followed by PQI reduction to PAP at -300 mV vs Ag/AgCl. Dual-electrode detection amplified the signal fourfold compared to single-electrode detection, and the recycling efficiency reached 87%. A calibration curve of PAP concentration vs anodic current was linear between 10(-4) and 10(-6) M. A signal from 1000 beads in a 20-muL drop was detectable and the immunoassay was complete within 10 min with a detection limit of 3.5 x 10(-15) mol mouse IgG. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 43 条
[1]   Self-contained microelectrochemical immunoassay for small volumes using mouse IgG as a model system [J].
Aguilar, ZP ;
Vandaveer, WR ;
Fritsch, I .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3321-3329
[2]  
ANGERSTE.H, 1973, J ELECTROANAL CHEM, V43, P9, DOI 10.1016/0368-1874(73)80226-6
[3]   QUANTITATIVE-ANALYSIS OF REVERSIBLE DIFFUSION-CONTROLLED CURRENTS OF REDOX SOLUBLE SPECIES AT INTERDIGITATED ARRAY ELECTRODES UNDER STEADY-STATE CONDITIONS [J].
AOKI, K ;
MORITA, M ;
NIWA, O ;
TABEI, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 256 (02) :269-282
[4]  
BARD AJ, 1989, ELECTROANALYTICAL CH, V15
[5]   ENZYMATIC AMPLIFICATION FOR SPECTROPHOTOMETRIC AND ELECTROCHEMICAL ASSAYS OF NAD+ AND NADH [J].
BERGEL, A ;
SOUPPE, J ;
COMTAT, M .
ANALYTICAL BIOCHEMISTRY, 1989, 179 (02) :382-388
[6]  
Blanchard RM, 2000, ANAL CHEM, V72, P1365, DOI 10.1021/ac991293l
[7]   Investigation of bioaffinity with electrochemical detection-characterization of different combinations of markers and electrodes [J].
Burckardt, R ;
Göpel, W .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 65 (1-3) :82-84
[8]   AN ELECTROCHEMICAL IMMUNOASSAY FOR CLOSTRIDIUM-PERFRINGENS PHOSPHOLIPASE-C [J].
CARDOSI, M ;
BIRCH, S ;
TALBOT, J ;
PHILLIPS, A .
ELECTROANALYSIS, 1991, 3 (03) :169-176
[9]   MICROMETER-SPACED PLATINUM INTERDIGITATED ARRAY ELECTRODE - FABRICATION, THEORY, AND INITIAL USE [J].
CHIDSEY, CE ;
FELDMAN, BJ ;
LUNDGREN, C ;
MURRAY, RW .
ANALYTICAL CHEMISTRY, 1986, 58 (03) :601-607
[10]   Enzyme microgels in packed-bed bioreactors with downstream amperometric detection using microfabricated interdigitated microsensor electrode arrays [J].
Guiseppi-Elie, A ;
Sheppard, NF ;
Brahim, S ;
Narinesingh, D .
BIOTECHNOLOGY AND BIOENGINEERING, 2001, 75 (04) :475-484