Radiation Dose Image Quality Optomization in Dental Implantalogy

被引:0
|
作者
Al-Humairi, Ahmed [1 ]
Zheng, Xiaoming [1 ]
Ip, Ho Leung [1 ]
El Masoud, Bilal [2 ,3 ]
机构
[1] Charles Sturt Univ, Wagga Wagga, NSW, Australia
[2] Charles Sturt Univ, Orange, NSW, Australia
[3] Jordan Univ Sci & Technol, Irbid, Jordan
关键词
optimization; image quality; CBCT; visual grading analysis; BEAM COMPUTED-TOMOGRAPHY; CONE-BEAM; DENTISTRY; CBCT; CT;
D O I
暂无
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
This paper is aimed to investigate the possibility of using a new method of dose and image quality optimization by employing visual grading analysis with a slight modification. Cone beam CT was utilized with different exposure settings to acquisition several images to skull phantom. Three different observers were involved with moderate agreement using Kappa factor. As a result, the new method introduced could be applied successfully in radiation dose and image quality optimization with the potential of achieving low dose level protocols with acceptable image quality in dental implantalogy.
引用
收藏
页码:403 / 406
页数:4
相关论文
共 50 条
  • [1] Image quality and radiation dose assessment of dental CBCT
    Huang, Jinfeng
    Chen, Xiaozhao
    Wang, Hong
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2022, 18 : 42 - 42
  • [2] Editorial: Radiation dose and image quality
    Manning, David
    RADIOGRAPHY, 2014, 20 (04) : 291 - 292
  • [3] CT radiation dose and image quality
    Payne, JT
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2005, 43 (06) : 953 - +
  • [4] Mammography radiation dose and image quality
    Jacobson, DR
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 295 - 297
  • [5] Tradeoffs in image quality and radiation dose
    McNitt-Gray, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1802 - 1802
  • [6] Dental-CT: Image quality and absorbed radiation dose of different scan protocols.
    Schorn, C
    Visser, H
    Hermann, KP
    Alamo, L
    Funke, M
    Grabbe, E
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (02): : 137 - 144
  • [7] Evaluating phantom image quality parameters to optimise patient radiation dose in dental digital radiology
    Gonzalez, Luciano
    Vano, Eliseo
    Fernandez, Ramon
    Ziraldo, Viviana
    Delgado, Jaime
    Delgado, Victor
    Moro, Javier
    Ubeda, Carlos
    RADIATION PROTECTION DOSIMETRY, 2012, 151 (01) : 95 - 101
  • [8] Image quality analysis and low dose dental CT
    Bianchi, SD
    Rampado, O
    Luberto, L
    Genovesio, AF
    Bianchi, CC
    Ropolo, R
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1177 - 1181
  • [9] Radiation dose and image quality in computed tomography
    Prokop, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (05): : 631 - 636
  • [10] Radiation dose and image quality in diagnostic radiology
    Geijer, H
    ACTA RADIOLOGICA, 2002, 43 : 4 - 43