Two cannulated hip screws for femoral neck fractures: treatment of choice or asking for trouble?

被引:25
作者
Krastman, Patrick
van den Bent, Rob P.
Krijnen, Pieta
Schipper, Inger B.
机构
[1] Univ Rotterdam Hosp, Erasmus Med Ctr, Dept Gen Surg & Traumatol, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Med Ctr, Dept Publ Hlth, Rotterdam, Netherlands
关键词
hip fracture; garden; Pauwels; osteosynthesis; minimal invasive fixation; cannulated screw; reintervention; hemi-arthroplasty; functional outcome;
D O I
10.1007/s00402-006-0143-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Undisplaced intracapsular fractures are predominantly treated with a minimally invasive fixation technique, whereas the standard treatment for displaced intracapsular fractures is still a subject of discussion. The purpose of this study was to identify the determinants influencing the outcome of intracapsular femoral neck fractures, treated with two cannulated hip screws. Patients and methods: From January 1998 through December 2002 data of all consecutive patients with an intracapsular femoral fracture, treated with two cannulated screws, were documented. Consolidation was chosen as the primary endpoint, mortality and a reoperation for replacement of osteosynthesis were defined secondary endpoints. Results: One hundred and twelve patients were included in the study. Fifty six percent of the intracapsular fractures healed within 1 year. Consolidation was accomplished in 95% of the stable fractures. Consolidation rates were negatively influenced by unstable fractures and inadequate anatomical reduction. The position of the screws did not influence consolidation rates. Reintervention rates were related to the number of local complications and the fracture type. Conclusion: In conclusion, the results of this study show that in case of operative treatment, undisplaced femoral neck fractures can be adequately fixated by two cannulated hip screws. Unstable, anatomically reduced femoral neck fracture (Garden III/IV) may be treated with a more stable implant (e.g. DHS) to avoid redisplacement. If adequate reduction cannot be achieved, endoprosthetic replacement is recommended.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [21] Dynamic hip system blade versus cannulated compression screw for the treatment of femoral neck fractures: A retrospective study
    Chen, Chao
    Yu, Li
    Tang, Xin
    Liu, Mo-zhen
    Sun, Li-zhong
    Liu, Changjian
    Zhang, Zhen
    Li, Chang-zhou
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (05) : 381 - 387
  • [22] High incidence of "in-out-in" posterosuperior screws after cannulated screw fixation of femoral neck fractures
    Yuan, Brandon J.
    Shamaa, Mohamad Tayseer
    Aibinder, William R.
    Parry, Joshua A.
    Cross, William W.
    Barlow, Jonathan D.
    Sems, Stephen A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (08) : 1417 - 1420
  • [23] The effect of bone morphogenetic protein 2 composite materials combined with cannulated screws in treatment of acute displaced femoral neck fractures
    Gao, Hongwei
    Xing, Deguo
    Liu, Zhonghao
    Zheng, Jiachun
    Xiong, Zhenggang
    Gong, Mingzhi
    Liu, Lan
    MEDICINE, 2020, 99 (06)
  • [24] Comparison of the clinical efficacy of three cannulated screws with parallel distribution and inverted triangular distribution in the treatment of femoral neck fractures in the elderly
    Liu, Jiuxiang
    Zuo, Qiang
    Zhou, Hao
    Huang, Xiaowen
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2023, 26 (04)
  • [25] Strength Analyses of Screws for Femoral Neck Fractures
    Frydrysek, Karel
    Sir, Milan
    Pleva, Leopold
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2018, 38 (05) : 816 - 834
  • [26] Biomechanical comparison of antirotator compression hip screw and cannulated screw fixations in the femoral neck fractures
    Saglam, Necdet
    Kucukdurmaz, Fatih
    Kivilcim, Hakan
    Kurtulmus, Tuhan
    Sen, Cengiz
    Akpinar, Fuat
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (02) : 196 - 201
  • [27] A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults
    Siavashi, Babak
    Aalirezaei, Arash
    Moosavi, Mersad
    Golbakhsh, Mohammad Reza
    Savadkoohi, Dariush
    Zehtab, Mohammad Javad
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (10) : 2069 - 2071
  • [28] A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults
    Babak Siavashi
    Arash Aalirezaei
    Mersad Moosavi
    Mohammad Reza Golbakhsh
    Dariush Savadkoohi
    Mohammad Javad Zehtab
    International Orthopaedics, 2015, 39 : 2069 - 2071
  • [29] Comparison between headless cannulated screws and partially threaded screws in femoral neck fracture treatment: a retrospective cohort study
    Wang, Yilin
    Han, Na
    Zhang, Dianying
    Zhang, Peixun
    Jiang, Baoguo
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [30] Cannulated screws versus dynamic hip screw versus hemiarthroplasty versus total hip arthroplasty in patients with displaced and non-displaced femoral neck fractures: a systematic review and frequentist network meta-analysis of 5703 patients
    Nikolai Ramadanov
    Katarzyna Jóźwiak
    Michael Hauptmann
    Philip Lazaru
    Polina Marinova-Kichikova
    Dobromir Dimitrov
    Roland Becker
    Journal of Orthopaedic Surgery and Research, 18