Two cannulated hip screws for femoral neck fractures: treatment of choice or asking for trouble?

被引:25
|
作者
Krastman, Patrick
van den Bent, Rob P.
Krijnen, Pieta
Schipper, Inger B.
机构
[1] Univ Rotterdam Hosp, Erasmus Med Ctr, Dept Gen Surg & Traumatol, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Med Ctr, Dept Publ Hlth, Rotterdam, Netherlands
关键词
hip fracture; garden; Pauwels; osteosynthesis; minimal invasive fixation; cannulated screw; reintervention; hemi-arthroplasty; functional outcome;
D O I
10.1007/s00402-006-0143-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Undisplaced intracapsular fractures are predominantly treated with a minimally invasive fixation technique, whereas the standard treatment for displaced intracapsular fractures is still a subject of discussion. The purpose of this study was to identify the determinants influencing the outcome of intracapsular femoral neck fractures, treated with two cannulated hip screws. Patients and methods: From January 1998 through December 2002 data of all consecutive patients with an intracapsular femoral fracture, treated with two cannulated screws, were documented. Consolidation was chosen as the primary endpoint, mortality and a reoperation for replacement of osteosynthesis were defined secondary endpoints. Results: One hundred and twelve patients were included in the study. Fifty six percent of the intracapsular fractures healed within 1 year. Consolidation was accomplished in 95% of the stable fractures. Consolidation rates were negatively influenced by unstable fractures and inadequate anatomical reduction. The position of the screws did not influence consolidation rates. Reintervention rates were related to the number of local complications and the fracture type. Conclusion: In conclusion, the results of this study show that in case of operative treatment, undisplaced femoral neck fractures can be adequately fixated by two cannulated hip screws. Unstable, anatomically reduced femoral neck fracture (Garden III/IV) may be treated with a more stable implant (e.g. DHS) to avoid redisplacement. If adequate reduction cannot be achieved, endoprosthetic replacement is recommended.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 50 条
  • [1] Two cannulated hip screws for femoral neck fractures: treatment of choice or asking for trouble?
    Patrick Krastman
    Rob P. van den Bent
    Pieta Krijnen
    Inger B. Schipper
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 297 - 303
  • [2] Cannulated Screws or Hemiarthroplasty for Femoral Neck Fractures: Is There a Mortality Difference?
    Thompson, Austen L.
    Kuttner, Nicolas P.
    Greenberg, Marc
    Hidden, Krystin A.
    Yuan, Brandon J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2024, 38 (11) : 596 - 601
  • [3] Comparison of Early Clinical Results for Femoral Neck System and Cannulated Screws in the Treatment of Unstable Femoral Neck Fractures
    Zhou, Xiao-Qiang
    Li, Zhi-Qiang
    Xu, Ren-Jie
    She, Yuan-Shi
    Zhang, Xiang-Xin
    Chen, Guang-Xiang
    Yu, Xiao
    ORTHOPAEDIC SURGERY, 2021, 13 (06) : 1802 - 1809
  • [4] A Comparison of Dynamic Hip Screw and Two Cannulated Screws in the Treatment of Undisplaced Intracapsular Neck Fractures-Two-Year Follow-Up of 453 Patients
    Widhalm, Harald Kurt
    Arnhold, Richard
    Beiglboeck, Hannes
    Munteanu, Alexandru
    Lang, Nikolaus Wilhelm
    Hajdu, Stefan
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (10)
  • [5] Comparison Between Femoral Neck Systems and Cannulated Cancellous Screws in Treating Femoral Neck Fractures: A Meta-Analysis
    Tian, Peng
    Kuang, Lan
    Li, Zhi-jun
    Xu, Gui-jun
    Fu, Xin
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2022, 13
  • [6] Comparison of two tools for the measurement of interfragmentary movement in femoral neck fractures stabilised by cannulated screws
    Nabhani, Farhad
    Bradley, Edward J.
    Hodgson, Simon
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2010, 26 (06) : 610 - 615
  • [7] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiang, Jiabao
    Chen, Jialei
    Xing, Fei
    Liu, Hao
    Xiang, Zhou
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [8] Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis
    Jiabao Jiang
    Jialei Chen
    Fei Xing
    Hao Liu
    Zhou Xiang
    BMC Musculoskeletal Disorders, 24
  • [9] Reoperation for sliding hip screws vs cannulated cancellous screws in femoral neck fractures: A study from the Danish Fracture Database Collaborators
    Viberg, Bjarke
    Barat, Siar
    Rotwitt, Lars
    Gundtoft, Per Hviid
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (11): : 3805 - 3809
  • [10] The Effect of Configuration of Rhombic Cannulated Screws on Internal Fixation of Femoral Neck Fractures
    Guo, Jialiang
    Dong, Weichong
    Yin, Yingchao
    Zhang, Ruipeng
    Hou, Zhiyong
    Zhang, Yingze
    ORTHOPEDICS, 2020, 43 (02) : E72 - E78