Microextraction by packed sorbent: an emerging, selective and high-throughput extraction technique in bioanalysis

被引:36
|
作者
Pereira, Jorge [1 ]
Camara, Jose S. [1 ,2 ]
Colmsjo, Anders [3 ]
Abdel-Rehim, Mohamed [3 ,4 ]
机构
[1] Univ Madeira, Ctr Ciencias Exatas & Engn, CQM, P-9000390 Funchal, Portugal
[2] Univ Madeira, Ctr Ciencias Exatas & Engn, P-9000390 Funchal, Portugal
[3] Stockholm Univ, Dept Analyt Chem, S-10691 Stockholm, Sweden
[4] Natl Res Ctr Egypt, Cairo 12622, Egypt
关键词
micro-extraction techniques (ET); micro-extraction by packed sorbent (MEPS); sorbents; applications; future trends; CHROMATOGRAPHY-MASS SPECTROMETRY; SOLID-PHASE MICROEXTRACTION; PRESSURE LIQUID-CHROMATOGRAPHY; HUMAN PLASMA SAMPLES; HUMAN URINE SAMPLES; POLYCYCLIC AROMATIC-HYDROCARBONS; MOLECULARLY IMPRINTED POLYMER; MEPS-LC-MS/MS; WATER SAMPLES; SYRINGE MEPS;
D O I
10.1002/bmc.3156
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sample preparation is an important analytical step regarding the isolation and concentration of desired components from complex matrices and greatly influences their reliable and accurate analysis and data quality. It is the most labor-intensive and error-prone process in analytical methodology and, therefore, may influence the analytical performance of the target analytes quantification. Many conventional sample preparation methods are relatively complicated, involving time-consuming procedures and requiring large volumes of organic solvents. Recent trends in sample preparation include miniaturization, automation, high-throughput performance, on-line coupling with analytical instruments and low-cost operation through extremely low volume or no solvent consumption. Micro-extraction techniques, such as micro-extraction by packed sorbent (MEPS), have these advantages over the traditional techniques. This paper gives an overview of MEPS technique, including the role of sample preparation in bioanalysis, the MEPS description namely MEPS formats (on- and off-line), sorbents, experimental and protocols, factors that affect the MEPS performance, and the major advantages and limitations of MEPS compared with other sample preparation techniques. We also summarize MEPS recent applications in bioanalysis. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:839 / 847
页数:9
相关论文
共 50 条
  • [31] Therapeutic Monitoring of Tranexamic Acid Concentration: High-Throughput Analysis With Solid-Phase Microextraction
    Bojko, Barbara
    Vuckovic, Dajana
    Mirnaghi, Fatemeh
    Cudjoe, Erasmus
    Wasowicz, Marcin
    Jerath, Angela
    Pawliszyn, Janusz
    THERAPEUTIC DRUG MONITORING, 2012, 34 (01) : 31 - 37
  • [32] High-throughput profiling volatiles in edible oils by cooling assisted solid-phase microextraction technique for sensitive discrimination of edible oils adulteration
    Xu, Shengrui
    Li, Huimin
    Dong, Panlong
    Wang, Miaomiao
    Chen, Chang-Po
    Feng, Suling
    Fan, Jing
    ANALYTICA CHIMICA ACTA, 2022, 1221
  • [33] A high-throughput analysis of volatile compounds with various polarities using headspace stir bar sorptive extraction
    Su, Keran
    Liew, Christina Shu Min
    Huang, Yunle
    Goh, Rui Min Vivian
    Pua, Aileen
    Sun, Jingcan
    Ee, Kim Huey
    Liu, Shao Quan
    Lassabliere, Benjamin
    Jublot, Lionel
    Yu, Bin
    TALANTA, 2023, 257
  • [34] An improved analytical strategy combining microextraction by packed sorbent combined with ultra high pressure liquid chromatography for the determination of fluoxetine, clomipramine and their active metabolites in human urine
    Alves, Vera
    Goncalves, Joao
    Conceicao, Carlota
    Teixeira, Helena M.
    Camara, Jose S.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1408 : 30 - 40
  • [35] High-throughput analytical methods employing microextraction techniques: Towards fast analyses lasting a few seconds
    Carasek, Eduardo
    Scur, Rafael
    Bernardi, Gabrieli
    ADVANCES IN SAMPLE PREPARATION, 2023, 8
  • [36] High-throughput quantification of palladium in water samples by ion pair based-surfactant assisted microextraction
    Yamini, Yadollah
    Moradi, Morteza
    Tahmasebi, Elham
    ANALYTICA CHIMICA ACTA, 2012, 728 : 26 - 30
  • [37] Selective extraction of genotoxic impurities and structurally alerting compounds using polymeric ionic liquid sorbent coatings in solid-phase microextraction: Alkyl halides and aromatics
    Ho, Tien D.
    Joshi, Manishkumar D.
    Silver, Mark A.
    Anderson, Jared L.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1240 : 29 - 44
  • [38] A high-throughput approach for the determination of pesticide residues in cucumber samples using solid-phase microextraction on 96-well plate
    Bagheri, Habib
    Es'haghi, Ali
    Es-haghi, Ali
    Mesbahi, Noushin
    ANALYTICA CHIMICA ACTA, 2012, 740 : 36 - 42
  • [39] Re-exploring the high-throughput potential of microextraction techniques, SPME and MEPS, as powerful strategies for medical diagnostic purposes. Innovative approaches, recent applications and future trends
    Pereira, Jorge
    Silva, Catarina Luis
    Perestrelo, Rosa
    Goncalves, Joao
    Alves, Vera
    Camara, Jose S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (08) : 2101 - 2122
  • [40] Single drop microextraction in a 96-well plate format: A step toward automated and high-throughput analysis
    Mafra, Gabriela
    Vieira, Augusto A.
    Merib, Josias
    Anderson, Jared L.
    Carasek, Eduardo
    ANALYTICA CHIMICA ACTA, 2019, 1063 : 159 - 166