A simulation study on tissue harmonic imaging with a single-element intravascular ultrasound catheter

被引:11
作者
Frijlink, Martijn E. [1 ]
Goertz, David E.
Bouakaz, Ayache
van der Steen, Antonius F. W.
机构
[1] Erasmus Univ, Med Ctr, Rotterdam, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] INSERM U619, Tours, France
[4] Univ Tours, Tours, France
关键词
D O I
10.1121/1.2226069
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Recently, in vivo feasibility of tissue harmonic imaging with a mechanically rotated intravascular ultrasound (IVUS) catheter was experimentally demonstrated. To isolate the second harmonic signal content, a combination of pulse inversion and analog filtering was used. In this paper the development of a simulation tool to investigate nonlinear IVUS beams is reported, and the influence of transducer rotation and axial catheter-to-tissue motion on the efficiency of PI signal processing is evaluated. Nonlinear beams were simulated in homogeneous tissue-mimicking media at a transmit frequency of 20 MHz, which resulted in second harmonic pressure fields at 40 MHz. The competing effects of averaging and decorrelation between neighboring rf lines on the signal-to-noise ratio (SNR) were studied for a single point scatterer. An optimal SNR was achieved when lines were combined over 3 degrees-3.75 degrees. When the transducer was rotated with respect to point scatterers, simulating the acoustic response of tissue, the fundamental frequency suppression using PI degraded rapidly with increasing interpulse angles. The effect of axial catheter-to-tissue motion on the efficiency of pulse inversion seemed to be of less influence for realistic motion values. The results of this study will aid in the optimization of harmonic IVUS imaging systems. (c) 2006 Acoustical Society of America.
引用
收藏
页码:1723 / 1731
页数:9
相关论文
共 37 条
[1]  
Angelsen B. A. J., 2000, ULTRASOUND IMAGING W, VI
[2]  
Averkiou MA, 1997, 1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, P1561, DOI 10.1109/ULTSYM.1997.663294
[3]   Nonlinear distortion of short pulses radiated by plane and focused circular pistons [J].
Averkiou, MA ;
Hamilton, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (05) :2539-2548
[4]   Harmonic ultrasonic field of medical phased arrays:: Simulations and measurements [J].
Bouakaz, A ;
Lancée, CT ;
de Jong, N .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (06) :730-735
[5]   Experimental characterization of fundamental and second harmonic beams for a high-frequency ultrasound transducer [J].
Cherin, EW ;
Poulsen, JK ;
van der Steen, AFW ;
Lum, P ;
Foster, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (05) :635-646
[6]  
Duck A., 1990, PHYS PROPERTIES TISS
[7]   Nonlinear acoustics in diagnostic ultrasound [J].
Duck, FA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (01) :1-18
[8]   Acoustic saturation and output regulation [J].
Duck, FA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (06) :1009-1018
[9]   A history of medical and biological imaging with polyvinylidene fluoride (PVDF) transducers [J].
Foster, FS ;
Harasiewicz, EA ;
Sherar, MD .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (06) :1363-1371
[10]  
Frijlink ME, 2004, ULTRASON, P1118