A novel thermal water pump for circulating water in a solar water heating system

被引:8
作者
Roonprasang, Natthaphon [1 ]
Namprakai, Pichai [1 ]
Pratinthong, Naris [1 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Sch Energy Environm & Mat, Div Energy Technol, Bangkok 10140, Thailand
关键词
Thermal water pump; Water circulation; Parametric study;
D O I
10.1016/j.applthermaleng.2008.07.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
This research purpose was to perform a parametric study of a novel thermal water pump well fitted in a simulated solar water heating system (SWHS). The SWHS was composed of a heating tank (HT), a hot water storage tank (ST) and an overhead tank (OT). The HT together with a specially designed valve act as a novel thermal water pump that gets power from hot water vapor and air pressure produced by a built-in electric heater in order to transfer heat from the HT to ST. The general operation of this pump has four stages for each cycle: heating, water circulating, vapor circulating and water supplying. The discharge water heads were varied with an increment of 0.25 m from 0.75 to 3 m. According to the experiment. it was found that the pump could operate at an average HT temperature of about 80-95 degrees C leading to 70-80 degrees C ST temperatures and 20-35 pumping cycles and consumed 17 MJ energy input during 9-h period. The overall thermal efficiency of the SWHS was 33-42% and the mean pump efficiency was about 0.005-0.011% depending upon the discharge heads. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1598 / 1605
页数:8