Development of a soft tissue seal around bone-anchored transcutaneous amputation prostheses

被引:127
作者
Pendegrass, Catherine J.
Goodship, Allen E.
Blunn, Gordon W.
机构
[1] Royal Natl Orthopaed Hosp Trust, Ctr Biomed Engn, Inst Orthopaed & Musculoskeletal Sci, Stanmore HA7 4LP, Middx, England
[2] Univ London Royal Vet Coll, Hatfield AL9 7TA, Herts, England
关键词
intraosseous; transcutaneous; amputation; prostheses;
D O I
10.1016/j.biomaterials.2006.03.041
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Conventional amputation prosthetics are problematic because they rely on the stump-socket interface for attachment. Intraosseous transcutaneous amputation prostheses (ITAP) could solve these problems however they rely on the integrity of the soft tissue-implant interface as a barrier to exogenous agents, and in the prevention of downgrowth and marsupilisation. We have used an in vivo animal model to study the soft tissue interfaces around bone-anchored transcutaneous implants. We hypothesise that by facilitating and increasing the area of dermal attachment to the implant epithelial down-growth will be reduced. A flange with a series of 24, 0.7 mm holes positioned immediately below the epithelium was used to increase dermal attachment. This significantly reduced downgrowth and optimised the integrity of the collagenous tissue-implant interface at the dermal level. We postulate that the flange reduces relative interfacial movement at the epithelium-implant interface by providing increased surface area for dermal tissue attachment. A tight seal at the dermal tissue level reduces the degree of downgrowth around ITAP, eliminating marsupilisation as a potential failure modality. Surface topography and coatings did not affect the degree of downgrowth or dermal attachment to straight or flanged implants. A significant negative correlation was observed between downgrowth and both epithelial and dermal attachment. This study shows that a soft tissue-implant interface capable of preventing downgrowth and marsupilisation can develop around a bone-anchored transcutaneous implant, given the incorporation of a porous flange positioned in the dermal tissues immediately below the epithelium. This will benefit applications
引用
收藏
页码:4183 / 4191
页数:9
相关论文
共 35 条
[11]  
DALY B, 1980, NOIHV829192 NAT TECH
[12]  
GROSSESIESTRUP C, 1997, P 1 M INT SOC ART OR, V1, P86
[13]   On the stereotropism of embryonic cells [J].
Harrison, RG .
SCIENCE, 1911, 34 (01) :279-281
[14]   HISTOLOGICAL INVESTIGATION OF INFLUENCE OF ADULT PORCINE GINGIVAL CONNECTIVE TISSUES IN DETERMINING EPITHELIAL SPECIFICITY [J].
HEANEY, TG .
ARCHIVES OF ORAL BIOLOGY, 1977, 22 (03) :167-174
[15]   INHIBITION OF ENDOTHELIAL REGENERATION BY TYPE-BETA TRANSFORMING GROWTH-FACTOR FROM PLATELETS [J].
HEIMARK, RL ;
TWARDZIK, DR ;
SCHWARTZ, SM .
SCIENCE, 1986, 233 (4768) :1078-1080
[16]   THE ROLE OF MEMBRANE MEMBRANE INTERACTIONS IN THE REGULATION OF ENDOTHELIAL CELL-GROWTH [J].
HEIMARK, RL ;
SCHWARTZ, SM .
JOURNAL OF CELL BIOLOGY, 1985, 100 (06) :1934-1940
[17]  
Holgers KM, 2000, AUDIOLOGY, V39, P253
[18]  
KOHLER P, 1989, PROSTHET ORTHOT INT, V13, P149
[19]   Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees - A preliminary study [J].
Lee, VSP ;
Solomonidis, SE ;
Spence, WD .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (02) :167-180
[20]  
LEVY SW, 1995, CUTIS, V55, P297