The First 100 Eyes of Standardized Descemet Stripping Automated Endothelial Keratoplasty versus Standardized Descemet Membrane Endothelial Keratoplasty

被引:174
作者
Hamzaoglu, Ebru C. [1 ]
Straiko, Michael D. [1 ]
Mayko, Zachary M. [2 ]
Sales, Christopher S. [1 ]
Terry, Mark A. [1 ]
机构
[1] Devers Eye Inst, Cornea Dept, Portland, OR USA
[2] Lions VisionGift, Portland, OR USA
关键词
LARGE PROSPECTIVE SERIES; VISUAL-ACUITY; DONOR TISSUE; FOLLOW-UP; CELL LOSS; DMEK; OUTCOMES; GRAFT; ASTIGMATISM; PARAMETERS;
D O I
10.1016/j.ophtha.2015.07.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare results of the first 100 eyes of Descemet stripping automated endothelial keratoplasty (DSAEK) and Descemet membrane endothelial keratoplasty (DMEK) that were performed with a standardized technique at a single institution. Design: Single-center, retrospective case series. Participants: The first 100 eyes of standardized DSAEK and DMEK that underwent surgery for Fuchs corneal dystrophy at our center. We excluded patients with prior ocular surgery other than cataract surgery to limit confounding variables. Methods: Best spectacle-corrected visual acuity (BSCVA; in logarithm of the minimal angle of resolution [logMAR] units) was obtained and specular microscopy of donor corneal tissue was performed before surgery. Postoperative complications, BSCVA, and the percent of endothelial cell loss (ECL) recorded at 6 months were compared with the Student t test. Patients with pre-existing ocular comorbidity that impacted visual potential such as macular degeneration, amblyopia, advanced glaucoma, and other optic neuropathies were excluded from the analysis of visual acuity, but were included for the outcomes of complications and ECL. Main Outcome Measures: Visual acuity improvement, ECL 6 months after surgery, postoperative complications, iatrogenic primary graft failure (IPGF), and rebubbling. Results: Of the 200 eyes, 62 DSAEK eyes and 70 DMEK eyes had 6-month BSCVA available and no vision-limiting comorbidities. Mean BSCVA increased from 0.41 +/- 0.19 logMAR and 0.27 +/- 0.11 logMAR before surgery to 0.20 +/- 0.13 logMAR and 0.11 +/- 0.13 logMAR 6 months after DSAEK and DMEK, respectively (P < 0.001). Seventy-one DSAEK eyes and 70 DMEK eyes had 6-month ECL data available: ECL was 25.9 +/- 14.0% after DSAEK and 27.9 +/- 16.0% after DMEK (P = 0.38). There were no IPGFs in the DSAEK cohort and there were 4 of 100 IPGFs after DMEK (P = 0.12). Rebubbling was performed in 2 of 100 eyes after DSAEK and in 6 of 100 eyes after DMEK (P = 0.28). Conclusions: Compared with DSAEK, DMEK provided better visual recovery and comparable 6-month ECL. The DMEK group had a higher, although not statistically significant, percentage of rebubbling procedures and IPGFs. (C) 2015 by the American Academy of Ophthalmology.
引用
收藏
页码:2193 / 2199
页数:7
相关论文
共 40 条
[1]   Risk of Corneal Transplant Rejection Significantly Reduced with Descemet's Membrane Endothelial Keratoplasty [J].
Anshu, Arundhati ;
Price, Marianne O. ;
Price, Francis W., Jr. .
OPHTHALMOLOGY, 2012, 119 (03) :536-540
[2]   Double port injector device to reduce endothelial damage in DMEK [J].
Arnalich-Montiel, F. ;
Munoz-Negrete, F. J. ;
De Miguel, M. P. .
EYE, 2014, 28 (06) :748-751
[3]   Changes in Corneal Curvatures and Anterior Segment Parameters after Descemet Stripping Automated Endothelial Keratoplasty [J].
Bahar, Irit ;
Kaiserman, Igor ;
Livny, Eitan ;
Slomovic, Alana ;
Slomovic, Allan .
CURRENT EYE RESEARCH, 2010, 35 (11) :961-966
[4]   Ultrathin Descemet's Stripping Automated Endothelial Keratoplasty with the Microkeratome Double-Pass Technique Two-Year Outcomes [J].
Busin, Massimo ;
Madi, Silvana ;
Santorum, Paolo ;
Scorcia, Vincenzo ;
Beltz, Jacqueline .
OPHTHALMOLOGY, 2013, 120 (06) :1186-1194
[5]  
Dapena I., 2011, Arch Soc Esp Oftalmol, V86, P395, DOI 10.1016/j.oftal.2011.05.030
[6]   Learning Curve in Descemet's Membrane Endothelial Keratoplasty First Series of 135 Consecutive Cases [J].
Dapena, Isabel ;
Ham, Lisanne ;
Droutsas, Konstantinos ;
van Dijk, Korine ;
Moutsouris, Kyros ;
Melles, Gerrit R. J. .
OPHTHALMOLOGY, 2011, 118 (11) :2147-2154
[7]   Standardized "No-Touch" Technique for Descemet Membrane Endothelial Keratoplasty [J].
Dapena, Isabel ;
Moutsouris, Kyros ;
Droutsas, Konstantinos ;
Ham, Lisanne ;
van Dijk, Korine ;
Melles, Gerrit R. J. .
ARCHIVES OF OPHTHALMOLOGY, 2011, 129 (01) :88-94
[8]   Visual Acuity Following Descemet-Membrane Endothelial Keratoplasty (DMEK): First 100 Cases Operated on for Fuchs Endothelial Dystrophy [J].
Droutsas, K. ;
Ham, L. ;
Dapena, I. ;
Geerling, G. ;
Oellerich, S. ;
Melles, G. .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (06) :467-477
[9]   Effect of the shape of the endothelial graft on the refractive results after Descemet's stripping with automated endothelial keratoplasty [J].
Esquenazi, Salomon ;
Rand, William .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2009, 44 (05) :557-561
[10]   Descemet-stripping automated endothelial keratoplasty [J].
Gorovoy, Mark S. .
CORNEA, 2006, 25 (08) :886-889