Factors affecting the water odor caused by chloramines during drinking water disinfection

被引:25
|
作者
Wang, An-Qi [1 ,2 ]
Lin, Yi-Li [3 ]
Xu, Bin [1 ,2 ]
Hu, Chen-Yan [4 ]
Gao, Ze-Chen [1 ]
Liu, Zhi [1 ]
Cao, Tong-Cheng [5 ]
Gao, Nai-Yun [1 ]
机构
[1] Tongji Univ, State Key Lab Pollut Control & Resource Reuse, Key Lab Yangtze Water Environm, Coll Environm Sci & Engn,Minist Educ, Shanghai 200092, Peoples R China
[2] Shanghai Inst Pollut Control & Ecol Secur, Shanghai 200092, Peoples R China
[3] Natl Kaohsiung Univ Sci & Technol, Dept Safety Hlth & Environm Engn, Kaohsiung 824, Taiwan
[4] Shanghai Univ Elect Power, Coll Environm & Chem Engn, Shanghai 200090, Peoples R China
[5] Tongji Univ, Sch Chem Sci & Engn, Shanghai 200092, Peoples R China
关键词
Flavor profile analysis; Drinking water odor; Monochloramine decay; Dichloramine; ORGANIC CHLORAMINES; NDMA FORMATION; TAP WATER; CHLORINATION; TASTE; KINETICS; MODEL; DECAY;
D O I
10.1016/j.scitotenv.2018.05.188
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Chloramine disinfection is one of the most common disinfection methods in drinking water treatment. In this study, the temporal variability of water odors during monochloramine auto-decomposition was investigated to elucidate the characteristics of odor problems caused by adopting chloramine disinfection in tap water. Odor intensities and dominant odorant contributions were determined using the flavor profile analysis (FPA) and odor active value (OAV), respectively. During auto-decomposition of monochloramine, Cl-2/N molar ratio, pH, temperature, and the presence of NOM all affected odor intensity and odor temporal variation in drinking water. In general, decreasing pH from 8.5 to 6.0 led to increasing perceived odor intensity due to the formation of dichloramine. The major odorants responsible for chlorinous odor under acidic and non-acidic conditions were dichloramine and monochloramine, respectively. Chloraminated water with a Cl-2/N molar ratio of 0.6 or NOM concentration <2 mg-C L-1 inhibited odor intensity. Furthermore, the influence of rechlorination on chlorinous odor intensity for chloraminated water should not be neglected. The results of this study will be beneficial for the control of chlorinous odors caused by chloramine disinfection in drinking water. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:687 / 694
页数:8
相关论文
共 50 条
  • [21] INORGANIC CHLORAMINES AS DRINKING-WATER DISINFECTANTS - A REVIEW
    WOLFE, RL
    WARD, NR
    OLSON, BH
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1984, 76 (05): : 74 - 88
  • [22] Water & wastewater UV disinfection technology for drinking water
    不详
    FILTRATION & SEPARATION, 2014, 51 (05): : 18 - 20
  • [23] Drinking water and waste water disinfection: Strategies and problems
    Collivignarelli, C
    Conio, O
    Riganti, V
    Ziglio, G
    Bertanza, G
    ENVIRONMENTAL ENGINEERING & RENEWABLE ENERGY, 1998, : 285 - 293
  • [24] DETECTING TASTE AND ODOR IN DRINKING WATER
    SUFFET, IH
    SEGALL, S
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1971, 63 (09): : 605 - &
  • [25] TASTE AND ODOR IN DRINKING-WATER
    HOLLIDAY, MG
    PARK, JM
    PROCEEDINGS : 12TH INTERNATIONAL SYMPOSIUM ON WASTEWATER TREATMENT, 1989, : 301 - 316
  • [26] By-products formation during drinking water disinfection: A tool to assess disinfection efficiency?
    Von Gunten, U
    Driedger, A
    Gallard, H
    Salhi, E
    WATER RESEARCH, 2001, 35 (08) : 2095 - 2099
  • [27] Analyzing drinking water for disinfection byproducts
    Urbansky, ET
    Magnuson, ML
    ANALYTICAL CHEMISTRY, 2002, 74 (09) : 260A - 267A
  • [28] Electrochemical alternatives for drinking water disinfection
    Martinez-Huitle, Carlos A.
    Brillas, Enric
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (11) : 1998 - 2005
  • [29] Chlorinated and halazone in the disinfection of drinking water
    Fantus, B
    JOURNAL OF INFECTIOUS DISEASES, 1919, 24 : 191 - 203
  • [30] Formation of trihalomethanes by the disinfection of drinking water
    Latifoglu, A
    INDOOR AND BUILT ENVIRONMENT, 2003, 12 (06) : 413 - 417